Page 12 of 51 Report No. SH08090331-002
IEC/EN 60065
Clause
Requirement – Test
Result - Remark
Verdict
TRF No: IEC/EN 60065H
TRF originator Intertek ETL SEMKO SH
14.3.4.1
Class II transformers have adequate separation
between hazardous live parts and accessible parts
(double or reinforced insulation)
TR1 basic insulation minimum
5.0 mm between TR1 core
and primary, Supplementary
insulation minimum 5.0mm
between TR1 core and
secondary.
Pass
Coil formers and partition walls > 0,4 mm
TR1 bobbin: 0.8mm min.
Pass
14.3.4.2
Class I transformers, with basic insulation and
protective screening only if all 7 conditions of
14.3.4.2 are met
Class II construction
N/A
14.3.4.3
Separating transformers with at least basic
insulation
N/A
14.3.5.1
Class II transformers have adequate insulation
between hazardous live parts and accessible parts
(double or reinforced insulation)
TR1 basic insulation minimum
5.0 mm between TR1 core
and primary, Supplementary
insulation minimum 5.0mm
between TR1 core and
secondary.
Pass
Coil formers and partition walls > 0,4 mm
TR1 bobbin: 0.8mm min.
Pass
14.3.5.2
Class I transformers have adequate insulation
between hazardous live parts and accessible
conductive parts or those conductive parts or
protective screens connected to a protective earth
terminal
Class II construction
N/A
Winding wires connected to protective earth have
adequate current-carrying capacity
N/A
14.4
High voltage components
No such components
N/A
High-voltage components and assemblies:
U > 4 kV (peak) separately approved
N/A
Component meets category V-1 of IEC 60707
N/A
14.4.1
High voltage transformers and multipliers tested as
part of the submission
N/A
14.4.2
High voltage assemblies and other parts tested as
part of the submission
N/A
14.5
Protective devices
Pass
Protective devices used within their ratings
Pass
External clearances and creepage distances meet
requirement of clause 13 for the voltage across the
device when opened
Fuse FU1: 4.9mm
Pass
14.5.1.1
a) Thermal cut-outs separately approved
No such components
N/A
b) Thermal cut-outs tested as part of the
submission
N/A
Page 13 of 51 Report No. SH08090331-002
IEC/EN 60065
Clause
Requirement – Test
Result - Remark
Verdict
TRF No: IEC/EN 60065H
TRF originator Intertek ETL SEMKO SH
14.5.1.2
a) Thermal links separately approved
No such components
N/A
b) Thermal links tested as part of the submission
N/A
14.5.1.3
Thermal devices re-settable by soldering
N/A
14.5.2.1
Fuse-links in the mains circuit according to IEC
60127
FU1 approved.
Pass
14.5.2.2
Correct marking of fuse-links adjacent to holder ....: FU1: T1A L 250V
Pass
14.5.2.3
Not possible to connect fuses in parallel ................: Only one fuse holder
Pass
14.5.2.4
Not possible to touch hazardous live parts when
replacing fuse-links without the use of a tool ..........:
Tools required.
N/A
14.5.3
PTC-S thermistors comply with IEC 60730-1
No such parts
N/A
PTC-S devices (15 W) category V-1 or better
N/A
14.5.4
Circuit protectors have adequate breaking capacity
and their position is correctly marked
N/A
14.6
Switches
No switch
N/A
14.6.1 a)
Separate testing to IEC 61058 including:
10 000 operations
Normal pollution suitability
Resistance to heat and fire level 3
and
V-0 compliance with annex G, G.1.1
10 000 operations
Normal pollution suitability
Resistance to heat and fire level 3
and
V-0 compliance with annex G, G.1.1
N/A
14.6.1 b)
Tested in the apparatus:
N/A
Switch controlling > 0.2A with open contact voltage
> 35 V (peak)/24 V dc complying with 14.6.3,
14.6.4 and V-0 in annex G, G.1.1
N/A
Switch controlling > 0.2A with open contact voltage
< 35 V (peak)/24 V dc complying with 14.6.3 and V-
0 in annex G, G.1.1
N/A
Switch controlling < 0.2A with open contact voltage
> 35 V (peak)/24 V dc complying with 14.6.4 and
V-0 in annex G, G.1.1
N/A
14.6.2
Switch tested to 14.6.1 b) constructed to IEC
61058-1 subclause 13.1 and has making/breaking
action independent of speed of actuation
N/A
14.6.3
Switch tested to 14.6.1 b) compliant with IEC
61058-1 subclause 16.2.2 d) and m) not attaining
excessive temperatures in use
N/A
14.6.4
Switch tested to 14.6.1 b) has adequate dielectric
strength
N/A
Page 14 of 51 Report No. SH08090331-002
IEC/EN 60065
Clause
Requirement – Test
Result - Remark
Verdict
TRF No: IEC/EN 60065H
TRF originator Intertek ETL SEMKO SH
14.6.5
Mains switch controlling mains socket outlets
additional tests to IEC 60058-1
N/A
Socket outlet current marking correct
N/A
14.7
Safety interlocks
No such parts
N/A
Safety interlocks to 2.8 of IEC 60950
N/A
14.8
Voltage setting devices
No such parts
N/A
Voltage setting device not likely to be changed
accidentally
N/A
14.9
Motors
N/A
14.9.1
Endurance test on motors
Only low voltage DC servo
motor in DVD loader
N/A
Motor start test
N/A
Dielectric strength test
N/A
14.9.2
Not adversely affected by oil or grease etc.
N/A
14.9.3
Protection against moving parts
N/A
14.9.4
Motors with phase-shifting capacitors, three-phase
motors and series motors meet clause. B.8, B.9
and B.10 of IEC 60950, Annex B
N/A
14.10
Batteries
Pass
14.10.1
Batteries mounted with no risk of accumulation of
flammable gases
Only non-rechargeable alkali
batteries in IR remote
controller.
Pass
14.10.2
No possibility of recharging non-rechargeable
batteries
No recharging circuit in
apparatus
N/A
14.10.3
Recharging currents and times within
manufacturers limits
No recharging circuit in
apparatus
N/A
Lithium batteries discharge and reverse currents
within the manufacturers limits
No lithium battery
N/A
14.10.4
Battery mould stress relief
No such battery
N/A
14.10.5
Battery drop test
No such battery
N/A
14.11
Optocouplers
Separately approved, see
appended table
Pass
Optocouplers comply with Cl. 8
Internal DTI >0.40mm
Pass
Internal and external dimensions to 13.1. or
alternatively 13.6 (jointed insulation)
int./ext. Cl. &Cr. >4mm /
≥
6.0mm
Pass
14.12
Surge suppression varistors
VDE approved
Pass
Comply with IEC 61051-2
Pass
Page 15 of 51 Report No. SH08090331-002
IEC/EN 60065
Clause
Requirement – Test
Result - Remark
Verdict
TRF No: IEC/EN 60065H
TRF originator Intertek ETL SEMKO SH
Not connected between mains and accessible
parts except for earthed parts of permanently
connected apparatus
Pass
Complies with the current pulse, fire hazard and
thermal stress requirements of 14.12
Pass
15
TERMINALS
15.1.1
Mains plug, appliance inlet, interconnection
couplers and mains socket-outlet meet the
appropriate standard
Mains plug approved
Pass
15.1.2
Connectors for antenna, earth, audio, video or data:
No risk of insertion in mains socket-outlets
Pass
No risk of insertion into audio or video: outlets
marked with the symbol of 5.2
N/A
15.1.3
Output terminals of a.c. adaptors or similar devices
not compatible with household mains socket-
outlets
N/A
15.2
Provision for protective earthing
Accessible conductive parts of Class I equipment
reliably connected to earth terminal, within
equipment
Class II
N/A
Class I supply equipment with non-hazardous live
output voltage: output circuit not connected to earth
N/A
Protective earth conductors correctly coloured
N/A
Equipment with non-detachable mains cord
provided with separate protective earth terminal
near mains input
N/A
Protective earth terminal resistant to corrosion
N/A
Earth resistance test: < 0,1
Ω
at 25 A ....................:
N/A
15.3
Terminals for external flexible cords and for
permanent connection to the mains supply
Pass
15.3.1
Adequate terminals for connection of permanent
wiring
N/A
15.3.2
Reliable connection of non-detachable cords:
Pass
Not soldered to conductors of a printed circuit
board
No.
Pass
Adequate clearances and creepage distances
between connections should a wire break away
Pass
Wire secured by additional means to the conductor Mating lock connector
Pass
Click on the first or last page to see other HD 990 (serv.man4) service manuals if exist.