Harman Kardon HD 990 (serv.man3) EMC - CB Certificate ▷ View online
Page 39 of 55 Report No. SH08090331-001
IEC/EN 60065
Clause
Requirement – Test
Result - Remark
Verdict
TRF No: IEC/EN 60065H
TRF originator Intertek ETL SEMKO SH
National differences for SINGAPORE
(According to CB bulletin No. 112A. These differences are taken from
IEC60065:1992 and adopted to IEC 60065:2001.)
(According to CB bulletin No. 112A. These differences are taken from
IEC60065:1992 and adopted to IEC 60065:2001.)
Throughout the standard
, whenever the words “white pine board” appear, insert
the words “or plywood board” to it.
Pass
SS 143 Amendment No.1 and No. 2
4.1.3
Delete “45 % to 75 %” and insert “65 _ 5 %”.
75% maximum in IEC
60065:2001
60065:2001
Pass
7.1
Resistance to heat without external forces
Adopt the temperature specified for the tropical
conditions.
Adopt the temperature specified for the tropical
conditions.
Pass
9.3.4
Delete the note “A Quality Assessment System
for capacitors complying with Subclause 14.2 is
under consideration in the IEC”.
for capacitors complying with Subclause 14.2 is
under consideration in the IEC”.
This is not in IEC 60065:2001.
Pass
10.2
Humidity treatment
Adopt the testing conditions designed for tropical
conditions.
Adopt the testing conditions designed for tropical
conditions.
120h at a relative humidity of
93%, ambient temperature
40
93%, ambient temperature
40
o
C
Pass
16
External flexible cords
Delete “IEC Publication 227: Polyvinyl Cloride
Insulated Cables of Rated Voltages up to and
Including 450/750 V and IEC Publication 245:
Rubber Insulated Cables of Rated Voltage up to
and including 450/750V” and insert “Singapore
Standard 236: Flexible Cords”, whenever they
appear in this clause.
Delete “CEE Publication 13, CEE Publication 2
and IEC Publication 173: Colours of the Cores of
Flexible Cables and Cords” whenever they
appear in this clause.
Delete “IEC Publication 227: Polyvinyl Cloride
Insulated Cables of Rated Voltages up to and
Including 450/750 V and IEC Publication 245:
Rubber Insulated Cables of Rated Voltage up to
and including 450/750V” and insert “Singapore
Standard 236: Flexible Cords”, whenever they
appear in this clause.
Delete “CEE Publication 13, CEE Publication 2
and IEC Publication 173: Colours of the Cores of
Flexible Cables and Cords” whenever they
appear in this clause.
Pass
16.2
Delete the notes in small print and insert “A
nominal cross-sectional area of 0.75 mm
nominal cross-sectional area of 0.75 mm
2
will
satisfy this requirement”.
Pass
16.4b
Delete “Subclause 3.1 of IEC Publication 227-2:
Part 2: Test Methods” and insert “Subclause 9.1
of SS 236”:
9.1 Flexing Test (except for tinsel cords, twisted
twin and single core cords).
The test shall be carried out by mieans of the
apparatus shown in Figure 5. This apparatus has
a carrier C supporting two pulleys A and B
arranged so that the cord is horizontal between
the pulleys. The carrier moves backward and
forward over a distance of 1 m at an
approximately constant speed of 0.33 m/s.
A sample of flexible cord fabout 5 m long shall be
stretched over the pulleys as shown in the figure,
each end being loaded with a weight. The weight
and the diameter of the pulleys A and B shall be
as given in Table 1.
Screene cords in accordance with Table 7 shall
Part 2: Test Methods” and insert “Subclause 9.1
of SS 236”:
9.1 Flexing Test (except for tinsel cords, twisted
twin and single core cords).
The test shall be carried out by mieans of the
apparatus shown in Figure 5. This apparatus has
a carrier C supporting two pulleys A and B
arranged so that the cord is horizontal between
the pulleys. The carrier moves backward and
forward over a distance of 1 m at an
approximately constant speed of 0.33 m/s.
A sample of flexible cord fabout 5 m long shall be
stretched over the pulleys as shown in the figure,
each end being loaded with a weight. The weight
and the diameter of the pulleys A and B shall be
as given in Table 1.
Screene cords in accordance with Table 7 shall
Pass
Page 40 of 55 Report No. SH08090331-001
IEC/EN 60065
Clause
Requirement – Test
Result - Remark
Verdict
TRF No: IEC/EN 60065H
TRF originator Intertek ETL SEMKO SH
be tested before application of the screen and
outer sheath.
The pulleys shall have a semi-circular shaped
groove for circular cords and a flat groove for
parallel twin cords. The
restraining clamps D shall be fixed so that the pull
is always applied by the weight from which the
carrier is mowing away. The carrier shall make 30
000 backward and forward movements (60 000
single strokes). Each conductor of the sample
shall be loaded with the current specified in Table
2.
For twin cords and for light PVC-sheated 3-core
cords, the voltage between the conductors shall
be approximately 230 V a.c. For all other cords
having three or more cores a three-phase a.c.
voltage of about 400 V shall be applied to three
conductors, any additional conductors being
connected to the neutral.
During the test no open-circuit in any core or
short-circuit between cores shall occur.
After the test, any sheath on cords having three
or more cores shall be removed. The cord, or the
laid up cores, shall then withstand the voltage
test specified in Subclause 8.2. or 8.3 as
appropriate, but with a test voltage not exceeding
2000 V.
TABLE 1, TABLE 2, FIGURES 4 and 5, see the
CB bulletin.
outer sheath.
The pulleys shall have a semi-circular shaped
groove for circular cords and a flat groove for
parallel twin cords. The
restraining clamps D shall be fixed so that the pull
is always applied by the weight from which the
carrier is mowing away. The carrier shall make 30
000 backward and forward movements (60 000
single strokes). Each conductor of the sample
shall be loaded with the current specified in Table
2.
For twin cords and for light PVC-sheated 3-core
cords, the voltage between the conductors shall
be approximately 230 V a.c. For all other cords
having three or more cores a three-phase a.c.
voltage of about 400 V shall be applied to three
conductors, any additional conductors being
connected to the neutral.
During the test no open-circuit in any core or
short-circuit between cores shall occur.
After the test, any sheath on cords having three
or more cores shall be removed. The cord, or the
laid up cores, shall then withstand the voltage
test specified in Subclause 8.2. or 8.3 as
appropriate, but with a test voltage not exceeding
2000 V.
TABLE 1, TABLE 2, FIGURES 4 and 5, see the
CB bulletin.
*In parenthesis: clauses according to IEC60065:1992.
National differences MALAYSIA, according to CB bulletin No. 1120A
IEC 60065(2001)
IEC 60065(2001)
+ Amendment 1 (2005).
Energy Commission circular no.1 year 2003
(no.1/2003)
States that a Certificate of Approval is required
for manufacturing, selling, Advertising, displaying
or importing into Malaysia, electrical/electronic
products Listed in Annex A.
(no.1/2003)
States that a Certificate of Approval is required
for manufacturing, selling, Advertising, displaying
or importing into Malaysia, electrical/electronic
products Listed in Annex A.
N/A
The supply voltage in Malaysia is 240 Vac, at
50Hz.
50Hz.
Pass
Class 0 and 01 appliances are not allowed
Pass
13A fused plug-tops shall comply to Malaysian
standard (MS 589:Part1:1997), if applicable.
standard (MS 589:Part1:1997), if applicable.
Same as BS1363 type.
Pass
2-pin plug tops shall comply to Malaysian
standard (MS 1578:2003) if applicable
standard (MS 1578:2003) if applicable
N/A
Page 41 of 55 Report No. SH08090331-001
Appendix no. 1 Photos of the product:
TRF No: IEC/EN 60065H
TRF originator Intertek ETL SEMKO SH
External views of EUT
Page 42 of 55 Report No. SH08090331-001
Appendix no. 1 Photos of the product:
TRF No: IEC/EN 60065H
TRF originator Intertek ETL SEMKO SH