Harman Kardon HD 990 (serv.man3) EMC - CB Certificate ▷ View online
Page 27 of 55 Report No. SH08090331-001
IEC/EN 60065
Clause
Requirement – Test
Result - Remark
Verdict
TRF No: IEC/EN 60065H
TRF originator Intertek ETL SEMKO SH
Operating conditions
PCB near IC1
45.2
34.9
75
EC1 (electrolytic capacitor)
16.9
14.9
70 (105-35)
Winding of TR1
25.9
19.2
65*
Bobbin of TR1
24.0
18.2
65
PCB near TR1
18.8
15.9
75
CY1 (Y1 capacitor)
10.6
10.9
50 (85-35)
CY3 (Y1 capacitor)
17.8
14.6
50 (85-35)
PCB near IC3
20.0
19.3
75
PCB near D15
30.4
29.2
75
EC19 (electrolytic capacitor)
18.5
17.9
70 (105-35)
Power cord
6.5
6.7
50
Enclosure (metallic)
4.8
4.6
30
Enclosure (non-metallic)
2.6
1.1
50
winding temperature rise measurements:
Temperature rise dT of winding:
R1 (Ω) R2 (Ω)
dT (K)
required
dT (K)
dT (K)
Insulation
class
class
10.3
TABLE: insulation resistance measurements
Pass
Insulation resistance R between:
R (MΩ)
Required R (MΩ)
Between mains poles (primary fuse disconnected)
100
2
Between parts separated by basic or supplementary insulation
100
2
Between parts separated by double or reinforced insulation
100
4
Between parts of TR1 separated by basic or supplementary
insulation
insulation
100 2
10.3
TABLE: electric strength measurements
P
Test voltage applied between:
Test voltage (V)
Breakdown
Mains poles (primary fuse disconnected)
2120Vp
No
Page 28 of 55 Report No. SH08090331-001
IEC/EN 60065
Clause
Requirement – Test
Result - Remark
Verdict
TRF No: IEC/EN 60065H
TRF originator Intertek ETL SEMKO SH
Test voltage applied between:
Test voltage (V)
Breakdown
Between parts separated by basic or supplementary insulation
2120Vp
No
Between parts separated by double or reinforced insulation
4240Vp
No
Between parts of TR1 separated by basic or supplementary
insulation
insulation
3220Vp No
11.2
TABLE: summary of fault condition tests
Pass
Model/type of power supply .................................: --
—
Voltage (V) 0,9 or 1,1 times rated voltage ............. : 100-240
Ambient temperature (
o
C) ...................................... : 24
—
No.
Component
No.
Fault
Test
voltage
(V)
Test
time
Fuse
No.
Fuse
current
(A)
Result
Dielectric
strength
test after
the test
1.
D8
SC
264
20 min.
FU1
0.029
P=2.5W. No extremely high
temperature, no hazard.
temperature, no hazard.
Pass
2.
EC5 SC
264
20 min.
FU1
0.17→
0.08
P=21.5W, 55s, P=8.4W, D8
damaged. No extremely high
temperature, no hazard.
damaged. No extremely high
temperature, no hazard.
Pass
3.
D10
SC
264 20
min.
FU1
0.29→
0.016
P=30W, 5s, P=0.9W. No
extremely high temperature,
no hazard.
extremely high temperature,
no hazard.
Pass
4.
EC10
SC
264
20 min.
FU1
0.16→
0.016
P=18.9W, 15s, P=0.9W, D10
damaged. No extremely high
temperature, no hazard.
damaged. No extremely high
temperature, no hazard.
Pass
5.
D11
SC
264 10
min.
FU1
0.016
P=0.9W, no high
temperature, no hazard.
temperature, no hazard.
Pass
6.
D12
SC
264 10
min.
FU1
0.027
P=2.3W, no high
temperature, no hazard.
temperature, no hazard.
Pass
7.
EC15
SC
264 20
min.
FU1
0.15→
0.23→
0.23→
0.016
P=18.4W, 50s, P=30W, 35s,
P=0.9W. No extreme high
temperature, no hazard.
P=0.9W. No extreme high
temperature, no hazard.
Pass
8.
D13
SC
264 50
min.
FU1
0.127
P=15.5W, no extreme high
temperature, no hazard.
temperature, no hazard.
Pass
9.
EC18
SC
264
10 min.
FU1
0.22→
0.016
P=32.5W, 12s, P=0.9W. No
extremely high temperature,
no hazard.
extremely high temperature,
no hazard.
Pass
10.
D6
SC
264
10 min.
FU1
0.016
P=0.9W. No high
temperature, no hazard.
temperature, no hazard.
Pass
11.
EC2
SC
264
10 min.
FU1
0.016
P=0.9W. No high
temperature, no hazard.
temperature, no hazard.
Pass
12.
D7
SC
264
10 min.
FU1
0.016
P=0.9W. No high
temperature, no hazard.
temperature, no hazard.
Pass
13.
EC3
SC
264
10 min.
FU1
0.016
P=0.9W. No high
temperature, no hazard.
temperature, no hazard.
Pass
Page 29 of 55 Report No. SH08090331-001
IEC/EN 60065
Clause
Requirement – Test
Result - Remark
Verdict
TRF No: IEC/EN 60065H
TRF originator Intertek ETL SEMKO SH
14.
D5
SC
264
10 min.
FU1
0.016
P=0.9W. No high
temperature, no hazard.
temperature, no hazard.
Pass
15.
EC12
SC
264
20 min.
FU1
0.16→
0.22→
0.27→
0.22→
0.27→
0.016
P=21W, 5s, P=14W, 85s,
P=27W, 5s, P=0.9W. D11
damaged. No extreme high
temperature, no hazard.
P=27W, 5s, P=0.9W. D11
damaged. No extreme high
temperature, no hazard.
Pass
16.
PH1:
primary
SC 264
10
min.
FU1
0.016
P=0.9W. No high
temperature, no hazard.
temperature, no hazard.
Pass
17.
D1
SC
264
2 s
FU1
>3
FU1 opened immediately,
P=0W, no high temperature,
no hazard.
P=0W, no high temperature,
no hazard.
Pass
18.
EC1
SC
264
2 s
FU1
>3
FU1 opened immediately,
P=0W, no high temperature,
no hazard.
P=0W, no high temperature,
no hazard.
Pass
19.
IC1:
pin1-pin2
SC 264 2
s FU1
>3
FU1 opened immediately,
P=0W, no high temperature,
no hazard.
P=0W, no high temperature,
no hazard.
Pass
20.
D15
SC
264
20 min.
FU1
0.19→
0.21→
0.21→
0.016
P=24W, 50s, P=27W, 40s,
P=0.9W. No extreme high
temperature, no hazard.
P=0.9W. No extreme high
temperature, no hazard.
Pass
21.
EC20
SC
264
20 min.
FU1
0.14→
0.15→
0.29→
0.15→
0.29→
0.016
P=17.5W, 15s, P=18.5W, 3
minutes, P=36W, 5s,
P=0.9W. No extreme high
temperature, no hazard.
minutes, P=36W, 5s,
P=0.9W. No extreme high
temperature, no hazard.
Pass
22.
PH1:
secondary
SC 264
10
min.
FU1
0.016
P=0.9W, IC1 damaged. No
high temperature, no hazard.
high temperature, no hazard.
Pass
(SC=short circuit, OC=open circuit, MUL=most unfavourable load)
13.3 & 13.4 TABLE: clearance and creepage distance measurements
Pass
clearance cl and creepage
distance dcr at/of:
Up
(V)
(V)
U r.m.s.
(V)
required cl
(mm)
cl
(mm)
required dcr
(mm)
dcr
(mm)
L to N (BI)
338
240
2.0
3.1
2.5
3.1
Primary circuit to accessible
parts / enclosure (RI)
parts / enclosure (RI)
338 240 4.0 6.0 5.0 6.0
Primary circuit to accessible
parts / enclosure (RI)
parts / enclosure (RI)
900 280 5.4 6.0 6.0 6.2
Transformer:
primary to secondary (RI)
primary to secondary (RI)
900 280 5.4 6.2 6.0 6.2
Transformer:
primary to core (BI)
primary to core (BI)
900 280 2.7 5.0 3.0 5.0
Transformer:
core to secondary (SI)
core to secondary (SI)
900 280 2.7 5.0 3.0 5.0
Page 30 of 55 Report No. SH08090331-001
IEC/EN 60065
Clause
Requirement – Test
Result - Remark
Verdict
TRF No: IEC/EN 60065H
TRF originator Intertek ETL SEMKO SH
14
TABLE: list of critical components and materials
Pass
Object/part No.
Manufacturer/
trademark
Type/model
Technical data
Standard
Mark(s) of
conformity
Power plug for
Europe
Europe
Well Shin
Technology CO.,
LTD.
Technology CO.,
LTD.
WS-019
16A, 250V~
DIN VDE 0620
IEC 60884
IEC 60884
VDE:
40011246
40011246
(alternative) Chau’s
Electrical
Co.,Ltd
CE-504
16A, 250V~
DIN VDE 0620
IEC 60884
IEC 60884
VDE:
40000141
40000141
Power cord for
Europe
(WS-019,CE-
504)
Europe
(WS-019,CE-
504)
Well Shin
Technology CO.,
LTD.
Technology CO.,
LTD.
HO5VV-F
2×0.75mm
2
DIN VDE 0281
IEC 60281
IEC 60281
VDE:
40007541
40007541
(alternative) Chau’s
Electrical
Co.,Ltd
HO5VV-F
2×0.75mm
2
DIN VDE 0281
IEC 60281
IEC 60281
VDE: 113934
Power plug for
Europe
LEONI 243 ~250V,
2.5A
IEC 60884
KEMA:
2087238.01
2087238.01
Power cord for
Europe (243)
LEONI
H03VVH2-F
2 x 0.75mm
2
DIN VDE 0281
IEC 60281
IEC 60281
VDE: 109835
Power plug for
Korea
LEONI (XIAMEN)
ELECTRONICS
CO.,LTD.
345K 3A,
250V~
KS C8305
KTL:
SU04019-
2005A
SU04019-
2005A
Power cord for
Korea
LEONI (XIAMEN)
ELECTRONICS
CO.,LTD.
60227 IEC 52
(H03VVH2-F)
2 x 0.75mm
2
2 x 0.75mm
2
K60227-5 KTL:
SU01011-
4003A
4003A
Power plug for
China
SHENZHEN
ZHENGERYA
CABLE CO.,
LTD.
ZEY-201 6A,
250V~
GB 2099.1-1996
GB 1002-1996
GB 1002-1996
CCC:
20020102010
02607
20020102010
02607
(alternative) LEONI
(XIAMEN)
ELECTRONICS
CO.,LTD.
LAP-11 6A,
250V~
GB 2099.1-1996
GB 1002-1996
GB 1002-1996
CCC:
20020102010
05577
20020102010
05577
Power cord for
China
SHENZHEN
ZHENGERYA
CABLE CO.,
LTD.
227 IEC 52
(
RVV)
2x0.75mm
2
GB 5023.5-97
CCC:
20040101051
18388
20040101051
18388
Click on the first or last page to see other HD 990 (serv.man3) service manuals if exist.