Harman Kardon HD 980 (serv.man5) EMC - CB Certificate ▷ View online
Page 28 of 51 Report No. SH08050531-002
IEC/EN 60065
Clause
Requirement – Test
Result - Remark
Verdict
TRF No: IEC/EN 60065H
TRF originator Intertek ETL SEMKO SH
Test voltage applied between:
Test voltage (V)
Breakdown
Between parts separated by basic or supplementary insulation
2120Vp
No
Between parts separated by double or reinforced insulation
4240Vp
No
Between parts of TR1 separated by basic or supplementary
insulation
insulation
3220Vp No
11.2
TABLE: summary of fault condition tests
Pass
Model/type of power supply .................................: --
—
Voltage (V) 0,9 or 1,1 times rated voltage ............. : 100-240
Ambient temperature (
o
C) ...................................... : 24
—
No.
Component
No.
Fault
Test
voltage
(V)
Test
time
Fuse
No.
Fuse
current
(A)
Result
Dielectric
strength
test after
the test
1.
D8
SC
264
20 min.
FU1
0.159→
0.190→
0.190→
0.029
P=19.8W, 30s, P=24.0W,
4 minutes, P=3.0W. No
extremely high temperature,
no hazard.
4 minutes, P=3.0W. No
extremely high temperature,
no hazard.
Pass
2.
EC5 SC
264
20 min.
FU1
0.156→
0.31→
0.068
P=19.4W, 30s, P=34.0W, D8
damaged, P=7.6W. No
extremely high temperature,
no hazard.
damaged, P=7.6W. No
extremely high temperature,
no hazard.
Pass
3.
D10
SC
264 5
min.
FU1
0.015
P=0.9W, no high
temperature, no hazard.
temperature, no hazard.
Pass
4.
EC10
SC
264
20 min.
FU1
0.17→
0.38→
0.38→
0.13
P=21.3W, 10s, P=42W, 10s,
P=10.6W max. No extreme
high temperature, no hazard.
P=10.6W max. No extreme
high temperature, no hazard.
Pass
5.
D11
SC
264 5
min.
FU1
0.015
P=0.9W, no high
temperature, no hazard.
temperature, no hazard.
Pass
6.
D12
SC
264 10
min.
FU1
0.196→
0.028
P=26.5W, 3 minutes,
P=2.3W. No extremely high
temperature, no hazard.
P=2.3W. No extremely high
temperature, no hazard.
Pass
7.
EC15
SC
264 10
min.
FU1
0.039
P=3.9W, no high
temperature, no hazard.
temperature, no hazard.
Pass
8.
D13
SC
264 20
min.
FU1
0.10
P=11.7W, no extreme high
temperature, no hazard.
temperature, no hazard.
Pass
9.
EC18
SC
264
5 min.
FU1
0.20→
0
P=27W, 25s, P=0W. IC1
damaged No extreme high
temperature, no hazard.
Repeat three times.
damaged No extreme high
temperature, no hazard.
Repeat three times.
Pass
10.
D15
SC
264
10 min.
FU1
0.212→
0.032
P=26.7W, 2 minutes,
P=2.5W. No extremely high
temperature, no hazard.
P=2.5W. No extremely high
temperature, no hazard.
Pass
Page 29 of 51 Report No. SH08050531-002
IEC/EN 60065
Clause
Requirement – Test
Result - Remark
Verdict
TRF No: IEC/EN 60065H
TRF originator Intertek ETL SEMKO SH
11.
EC20
SC
264
20 min.
FU1
0.153→
0.203→
0.203→
0.015
P=18.4W, 3 minutes,
P=30.6W, 5s, P=0.9W. No
extreme high temperature, no
hazard.
P=30.6W, 5s, P=0.9W. No
extreme high temperature, no
hazard.
Pass
12.
PH1:
secondary
SC 264 5
min.
FU1
0.015
P=0.9W, IC1 damaged. No
high temperature, no hazard.
high temperature, no hazard.
Pass
13.
D6
SC
264
5 min.
FU1
0.01
P=0.1W, circuit protected, no
high temperature, no hazard.
high temperature, no hazard.
Pass
14.
EC2
SC
264
5 min.
FU1
0.01
P=0.1W, circuit protected, no
high temperature, no hazard.
high temperature, no hazard.
Pass
15.
D7
SC
264
5 min.
FU1
0.01
P=0.1W, circuit protected, no
high temperature, no hazard.
high temperature, no hazard.
Pass
16.
EC3
SC
264
5 min.
FU1
0.01
P=0.1W, circuit protected, no
high temperature, no hazard.
high temperature, no hazard.
Pass
17.
D5
SC
264
5 min.
FU1
0.01
P=0.1W, circuit protected, no
high temperature, no hazard.
high temperature, no hazard.
Pass
18.
EC12
SC
264
5 min.
FU1
0.17→
0.11→0
P=21W, 10s, P=14W, 33s,
D11 damaged, P=0W. No
extremely high temperature,
no hazard. Repeat three
times.
D11 damaged, P=0W. No
extremely high temperature,
no hazard. Repeat three
times.
Pass
19.
PH1:
primary
SC 264 5
min.
FU1
0.01
P=0.1W, circuit protected, no
high temperature, no hazard.
high temperature, no hazard.
Pass
20.
D1
SC
264
2 min.
FU1
>3
FU1 opened immediately,
P=0W, no high temperature,
no hazard.
P=0W, no high temperature,
no hazard.
Pass
21.
EC1
SC
264
2 min.
FU1
>3
FU1 opened immediately,
P=0W, no high temperature,
no hazard.
P=0W, no high temperature,
no hazard.
Pass
22.
IC1:
pin1-pin2
SC 264 2
min.
FU1
>3
IC1, FU1 damaged
immediately, P=0W, no high
temperature, no hazard.
immediately, P=0W, no high
temperature, no hazard.
Pass
(SC=short circuit, OC=open circuit, MUL=most unfavourable load)
13.3 & 13.4 TABLE: clearance and creepage distance measurements
Pass
clearance cl and creepage
distance dcr at/of:
Up
(V)
(V)
U r.m.s.
(V)
required cl
(mm)
cl
(mm)
required dcr
(mm)
dcr
(mm)
L to N (BI)
338
240
2.0
3.1
2.5
3.1
Primary circuit to accessible
parts / enclosure (RI)
parts / enclosure (RI)
338 240 4.0 6.0 5.0 6.0
Primary circuit to accessible
parts / enclosure (RI)
parts / enclosure (RI)
900 280 5.4 6.0 6.0 6.2
Transformer:
primary to secondary (RI)
primary to secondary (RI)
900 280 5.4 6.2 6.0 6.2
Transformer:
primary to core (BI)
primary to core (BI)
900 280 2.7 5.0 3.0 5.0
Page 30 of 51 Report No. SH08050531-002
IEC/EN 60065
Clause
Requirement – Test
Result - Remark
Verdict
TRF No: IEC/EN 60065H
TRF originator Intertek ETL SEMKO SH
Transformer:
core to secondary (SI)
core to secondary (SI)
900 280 2.7 5.0 3.0 5.0
14
TABLE: list of critical components and materials
Pass
Object/part No.
Manufacturer/
trademark
Type/model
Technical data
Standard
Mark(s) of
conformity
Mains plug for
Europe
LEONI 243 ~250V,
2.5A
IEC 60884
KEMA:
2087238.01
2087238.01
(alternative) LEONI
CW4014 ~250V,
2.5A
IEC 60884
KEMA:
2087238.04
2087238.04
(alternative) Quanzhou
lian
xin electronics
technology co,.
ltd.
LX-202 ~250V,
2.5A
IEC 60884
VDE:
40007544
40007544
Mains cord for
Europe
LEONI KABEL
HOLDING
GMBH&CO. KG
H03VVH2-F
2 x 0.75mm
2
DIN VDE 0281
IEC 60281
IEC 60281
VDE: 109835
(alternative) Shenzhen
dong
ju wire&cable
Co., Ltd.
H03VVH2-F
2×0.75mm
2
DIN VDE 0281
IEC 60281
IEC 60281
VDE: 129988
Mains plug for
UK
Hangzhou Fuxing
Electrical LTD
SW238I
SW238II
~250V, 13A
BS1363 ASTA:726
(alternative) Leoni
(Xiamen)
Electronics Co.,
Ltd.
360 ~250V,
13A
BS1363
ASTA:727
Fuse-link built in
the plug
(for UK)
HANGZHOU
FUXING
ELECTRICAL
LIMITED
Richstar 13A
13A, 240V,
50Hz
BS1362
BSI:
KM 34254
KM 34254
Page 31 of 51 Report No. SH08050531-002
IEC/EN 60065
Clause
Requirement – Test
Result - Remark
Verdict
TRF No: IEC/EN 60065H
TRF originator Intertek ETL SEMKO SH
Object/part No.
Manufacturer/
trademark
Type/model
Technical data
Standard
Mark(s) of
conformity
(alternative) HANGZHOU
FUXING
ELECTRICAL
LIMITED
Richstar 3A
3A, 240V, 50Hz BS1362
BSI:
KM 34254
KM 34254
(alternative) DONGGUAN
COOPER
ELECTRONICS
CO LTD
TDC 180
13A or 3A,
240V, 50Hz
BS1362
BSI:
KM 60192
KM 60192
Mains cord for
UK
LEONI KABEL
HOLDING
GMBH&CO. KG
H03VVH2-F
2 x 0.75mm
2
DIN VDE 0281
IEC 60281
IEC 60281
VDE: 109835
Fuse
FU1
Zhong Shan Lan
Bao Electrical
Appliances
RTI-20 T1AL
250V
IEC 60127
VDE:
40012120
40012120
(alternative) Hollyland
Co.,
Ltd.
50T T1AL
250V
IEC 60127
VDE:139231
(alternative) Shanghai
Songshan
Electronic Co.,
Ltd.
RF1-20 T1AL
250V
IEC 60127
VDE:138756
(alternative) WALTER
ELECTRONIC
CO.,LTD.
ICP T1AL
250V
IEC 60127
VDE:
40012824
40012824
X2 capacitor
CX1
Anhui Tongfeng
Electronics Co.,
Ltd.
MKP 0.1uF,
275V~
40/100/56/C
IEC 60384-14
2
2
nd
Ed.
SEMKO:
0204005/01
0204005/01
(alternative) Carli
Electronics
Co., Ltd
MPX
0.1 uF, 275V~
40/100/21/C
IEC 60384-14
2
2
nd
Ed.
VDE:
40008520
40008520
(alternative) UTX
Enterprise
Co.,Ltd
HQX
0.22 uF, 275V~
40/100/21/C
IEC 60384-14
2
2
nd
Ed.
NEMKO:
P97103028
P97103028
Click on the first or last page to see other HD 980 (serv.man5) service manuals if exist.