Harman Kardon GO PLAY WIRELESS (serv.man2) EMC - CB Certificate ▷ View online

Report No.:  EM201200637-3                Application No.:  ZJ00022731                        Page 61 of 81 
 
 
5.6.4 TEST RESULTS 
EUT 
Wireless Speaker Dock For iPad, iPhone and iPod 
Mode Number 
Harman Kardon Go+Play Wireless 
Test date 
2012-11-17 
Voltage Supply 
AC 230V/50Hz 
Test Engineer 
Liang 
environment 
Tem:21℃ Hum:50 %100kPa 
Test mode: 
1. Test the EUT in Audio in (Adapter ); BT (Adapter ); 
    BT(Adapter+Load)、Audio in (Adapter+Load); 
2. Test the EUT in idle mode. 
 
Test Point   Polarity
Test 
Level 
(kV) 
Phase
Performanc
Criterion 
Actual 
performanc
Result 
(P/F) 
L - N 
+/- 1 0°  B 
PASS 
+/- 1 90°  B 
PASS 
+/- 1 
180° B 
PASS 
+/- 1 
270° B 
PASS 
 
A*There was no change compared with the initial operation during the test. 
 
 
Report No.:  EM201200637-3                Application No.:  ZJ00022731                        Page 62 of 81 
 
 
5.7 INJECTED CURRENTS SUSCEPTIBILITY TEST 
5.7.1 TEST SPECIFICATION 
Basic Standard 
EN 61000-4-6:2009 
Frequency Range 
0.15 MHz-80 MHz 
Field Strength 
3 V 
Modulation 
1 kHz,80% AM 
Frequency Step 
1% 
Dwell time 
2s 
5.7.2 TEST PROCEDURE  
1)  Set up the EUT, CDN as shown on Section 5.7.3 
2)  Let the EUT work in test mode and measure it. 
3)   The EUT are placed on an insulating support 0.1m high above a ground reference plane. CDN 
(coupling and decoupling device) is placed on the ground plane about 0.3m from EUT. Cables 
between CDN and EUT are as short as possible, and their height above the ground reference 
plane shall be between 30 and 50 mm (where possible). 
4)  The disturbance signal described below is injected to EUT through CDN. 
5)  The EUT operates within its operational mode(s) under intended climatic conditions after 
power on. 
6)  The frequency range is swept from 150 kHz to 80MHz using 3V signal level, and with the 
disturbance signal 80% amplitude modulated with a 1 kHz sine wave. 
7) The rate of sweep shall not exceed 1.5*10-3decades/s. Where the frequency is swept 
incrementally, the step size shall not exceed 1% of the start and thereafter 1% of the preceding 
frequency value. 
8) Recording the EUT operating situation during compliance testing and decide the EUT 
immunity criterion. 
Report No.:  EM201200637-3                Application No.:  ZJ00022731                        Page 63 of 81 
 
5.7.3 TEST SETUP 
                                                
  
Report No.:  EM201200637-3                Application No.:  ZJ00022731                        Page 64 of 81 
 
 
5.7.4 TEST RESULTS 
EUT 
Wireless Speaker Dock For iPad, iPhone and iPod 
Mode Number 
Harman Kardon Go+Play Wireless 
Test date 
2012-11-17 
Voltage Supply 
AC 230V/50HZ 
Test Engineer 
Liang 
environment 
Tem:22℃ Hum:51 %100kPa 
Test mode: 
1. Test the EUT in Audio in (Adapter ); BT (Adapter ); 
BT(Adapter+Load)、Audio in (Adapter+Load); 
2. Test the EUT in idle mode. 
 
Frequency 
Band (MHz) 
Field  
Strength 
(Vrms) 
Cable 
Injection 
Method 
Required 
Passing 
Performance 
Actual 
performance
Result 
0.15-80 
AC Line CDN-M2/M3 Criterion A  Criterion A*
PASS 
A*: There was no change compared with initial operation during the test. 