Report No.:  EM201200637-3                Application No.:  ZJ00022731                        Page 53 of 81 
 
5.3.3 TEST SETUP 
 
 
 
Report No.:  EM201200637-3                Application No.:  ZJ00022731                        Page 54 of 81 
 
 
5.3.4 TEST RESULTS 
EUT 
Wireless Speaker Dock For iPad, iPhone and iPod 
Mode Number 
Harman Kardon Go+Play Wireless 
Test date 
2012-11-16 
Voltage Supply 
AC 230V/50Hz;Battery 
Test Engineer 
Liang 
environment 
Tem:25 Hum:50 %100kPa 
Test mode: 
1. Test the EUT in Audio in (Battery )、Audio in (Adapter )、Audio 
in(Adapter+Load)、BT (Battery )、BT (Adapter )、BT(Adapter+Load)
2. Test the EUT in idle mode. 
 
Discharge point 
Discharge 
voltage 
C-Conduct 
A-Air 
Required 
Passing 
Performance
Actual 
performance
Result
Nonmetallic 
exposed surface & 
button 
±8  kV 
Criterion B 
Criterion B* 
PASS 
Vertical coupling 
plane 
±4  kV 
Criterion B 
Criterion B* 
PASS 
Horizontal coupling 
plane 
±4  kV 
Criterion B 
Criterion B* 
PASS 
B*: The data lost during the test, and recovered automatically when the test finished. 
 
Report No.:  EM201200637-3                Application No.:  ZJ00022731                        Page 55 of 81 
 
 
5.4 RADIATED, RADIO-FREQUENCY, ELECTROMAGNETIC FIELD (RS) 
5.4.1 TEST SPECIFICATION 
Basic Standard 
EN 61000-4-3: 2006+A1: 2008+A2: 2010 
Frequency Range 
80 MHz ~1000 MHz 
1.4 GHz ~2.7GHz 
Field Strength 
3 V/m 
Modulation 
1kHz Sine Wave, 80% AM Modulation 
Frequency Step 
1 % of preceding frequency value 
Dwell Time 
2s 
Polarity of Antenna 
Horizontal and Vertical 
Test Distance 
3 m 
Antenna Height 
1.5m 
 
5.4.2 TEST PROCEDURE  
a) The testing was performed in a fully anechoic chamber. The transmit antenna was located at a 
distance of 3 meters from the EUT. 
b) The frequency range is swept from 80 MHz to 1000 MHz; 1.4 GHz ~2.7GHz ,with the signal 80% 
amplitude modulated with a 1 kHz sine-wave. The rate of sweep did not exceed 1.5 x 10 
-3 
decade/s, where the frequency range is swept incrementally; the step size was 1% of preceding 
frequency value. 
c) The dwell time at each frequency shall be not less than the time necessary for the EUT to be able to 
respond. 
e) The test was performed with the EUT exposed to both vertically and horizontally polarized fields 
on each of the four sides. 
Report No.:  EM201200637-3                Application No.:  ZJ00022731                        Page 56 of 81 
 
 
5.4.3 TEST SETUP 
 
 
 
 
 
 
 
 
 
 
 
                                 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
Power 
Amp 
Signal 
Generato
r
EUT Monitoring by 
using a camera
 
0.8m
Control Room
9
×
6
×
EUT& 
Support 
Units 
PC Controller to 
control S.G. & PA as 
well as forward 
power
 
3 meter 
1.5m 
Page of 81
Display