Harman Kardon GO PLAY WIRELESS (serv.man2) EMC - CB Certificate ▷ View online
Report No.: EM201200637-3 Application No.: ZJ00022731 Page 53 of 81
5.3.3 TEST SETUP
Report No.: EM201200637-3 Application No.: ZJ00022731 Page 54 of 81
5.3.4 TEST RESULTS
EUT
Wireless Speaker Dock For iPad, iPhone and iPod
Mode Number
Harman Kardon Go+Play Wireless
Test date
2012-11-16
Voltage Supply
AC 230V/50Hz;Battery
Test Engineer
Liang
environment
Tem:25 Hum:50 %100kPa
Test mode:
1. Test the EUT in Audio in (Battery )、Audio in (Adapter )、Audio
in(Adapter+Load)、BT (Battery )、BT (Adapter )、BT(Adapter+Load)
2. Test the EUT in idle mode.
Discharge point
Discharge
voltage
C-Conduct
A-Air
Required
Passing
Performance
Actual
performance
Result
Nonmetallic
exposed surface &
button
±8 kV
A
Criterion B
Criterion B*
PASS
Vertical coupling
plane
±4 kV
C
Criterion B
Criterion B*
PASS
Horizontal coupling
plane
±4 kV
C
Criterion B
Criterion B*
PASS
B*: The data lost during the test, and recovered automatically when the test finished.
Report No.: EM201200637-3 Application No.: ZJ00022731 Page 55 of 81
5.4 RADIATED, RADIO-FREQUENCY, ELECTROMAGNETIC FIELD (RS)
5.4.1 TEST SPECIFICATION
Basic Standard
EN 61000-4-3: 2006+A1: 2008+A2: 2010
Frequency Range
80 MHz ~1000 MHz
1.4 GHz ~2.7GHz
Field Strength
3 V/m
Modulation
1kHz Sine Wave, 80% AM Modulation
Frequency Step
1 % of preceding frequency value
Dwell Time
2s
Polarity of Antenna
Horizontal and Vertical
Test Distance
3 m
Antenna Height
1.5m
5.4.2 TEST PROCEDURE
a) The testing was performed in a fully anechoic chamber. The transmit antenna was located at a
distance of 3 meters from the EUT.
b) The frequency range is swept from 80 MHz to 1000 MHz; 1.4 GHz ~2.7GHz ,with the signal 80%
amplitude modulated with a 1 kHz sine-wave. The rate of sweep did not exceed 1.5 x 10
-3
decade/s, where the frequency range is swept incrementally; the step size was 1% of preceding
frequency value.
frequency value.
c) The dwell time at each frequency shall be not less than the time necessary for the EUT to be able to
respond.
e) The test was performed with the EUT exposed to both vertically and horizontally polarized fields
on each of the four sides.
Report No.: EM201200637-3 Application No.: ZJ00022731 Page 56 of 81
5.4.3 TEST SETUP
Power
Amp
Amp
Signal
Generato
r
EUT Monitoring by
using a camera
using a camera
0.8m
Control Room
9
×
6
×
6
EUT&
Support
Support
Units
PC Controller to
control S.G. & PA as
well as forward
power
control S.G. & PA as
well as forward
power
3 meter
1.5m