DOWNLOAD Harman Kardon GLA 55 (serv.man2) Service Manual ↓ Size: 1.44 MB | Pages: 39 in PDF or view online for FREE

Model
GLA 55 (serv.man2)
Pages
39
Size
1.44 MB
Type
PDF
Document
EMC - CB Certificate
Brand
Device
Audio
File
gla-55-sm2.pdf
Date

Harman Kardon GLA 55 (serv.man2) EMC - CB Certificate ▷ View online

Ident. Nr.: 
115972 
Date:  
2008-10-26 
 
115972 EMC TRF_verified 
page 13 of 39 
Measurement of radiated emission 
5.1 Standards 
Product or product family standard 
EN 55022:2006 
Limit class 
Class B 
Basic standard 
CISPR 16 
Date of testing 
 2008-09-26 
5.2 Measurement equipment 
 
Equipment 
Last Calibration 
Type 
 
Serial No
Manufacturer 
EMI Test Receiver  
January 25, 2008 ESI26 
SB3436 
Rohde & Schwarz 
Bilog Antenna 
January 25, 2008 CBL6112B SB3440 
Chase 
 
Semi-anechoic 
chamber 
January 25, 2008 9X6X6 
SB3450/01 Albatross 
Projects 
 
5.3 Test set-up 
 
The EUT has been tested according to the above-mentioned standard, as following: 
The EUT was placed on the top of an insulating table 0.8 meters above the ground at a semi-
anechoic chamber. The table was rotated 360 degrees to determine the position of the highest 
radiation. The EUT was set 3 meters away from the interference-receiving antenna, which was 
mounted on the top of a variable-height antenna tower. The antenna is a broadband antenna, and its 
height is varied from 1 to 4 meter above the ground to determine the maximum value of the field 
strength. Both horizontal and vertical polarizations of the antenna are set to make the measurement. 
For each suspected emission, the EUT was arranged to its worst case and then the antenna was 
tuned to the heights from 1 to 4 meters and the ratable table was turned from 0 degrees to 360 
degrees to find the maximum reading. The test-receiver system was set to Peak Detector Function 
and Specified Bandwidth with Maximum Hold Mode. 
If more details are necessary, e.g. because of wiring or auxiliary equipment, annex B with a photo or 
a rough figure of the test set-up is attached. 
The test has been performed as following: 
1)  Preview test; Peak; IF BW=120kHz, VBW=300kHz, Antenna: from 1 to 4m Turntable 0-360deg 
2)  Find frequencies with maximum emission: 
Acceptance-analysis: Limit minus 10 dB 
Peak-reduction: 10Peaks frequency range 30 MHz - 1000 MHz 
3)  Final test; Quasi-Peak; measuring time 1 s; at frequencies from step 2); Search maximum: vary 
turntable and antenna position to find the maximum readings 
4)  If there are more than 10 peaks within the 10 dB margin a manual test with all settings is 
necessary to find the maximum readings. 
The EUT ‘s internal freq is lower than 108MHz,so RE test above 1GHz is not necessary . 
 
5.4 Test result  
Mode 
Diagram   
Remarks 
Result 
TM1 
Diagram
  004 
H and V 
Pass 
Ident. Nr.: 
115972 
Date:  
2008-10-26 
 
115972 EMC TRF_verified 
page 14 of 39 
5.5  Diagrams and tables 
5.5.1  Diagram 004   
Test Specification:  Horizontal & Vertical 
Comment:             AC 230V/50Hz 
                      
 
  
10
20
30
40
50
Level [dBuV/m]
30M
50M 70M 100M
200M 300M
500M 700M 1G
Frequency [Hz]
MES  Prisma Hor             
MES  Prisma Ver             
LIM  EN55022               Field Strength QP Limit
 
  
 
Ident. Nr.: 
115972 
Date:  
2008-10-26 
 
115972 EMC TRF_verified 
page 15 of 39 
5.5.2 Table 005 
 
TM  
 
Emission Frequency
MHz 
Measured QP Level  
dB
μV/m 
Polarity 
Limit 
dB
μV/m 
78.711 31.1 
40 
TM1 
78.533 30.8 
40 
The emissions don’t show are too low against the limits, the test curves are shown above. 
Ident. Nr.: 
115972 
Date:  
2008-10-26 
 
115972 EMC TRF_verified 
page 16 of 39 
6 Harmonic 
current 
6.1 Standard 
Basic standard 
EN 61000-3-2:2006 
Date of testing 
2008-09-27 
6.2 Measurement equipment 
 
Equipment 
Last Calibration 
Type 
 
Serial No
Manufacturer
Power 
February 20, 2008  5001ix-CTS-400 
SB2588 
CI 
Three Phase Harmonic 
flicker test system 
February 20, 2008  PACS-3 
SB2588/01  CI 
Power 
February 20, 2008  5001ix-CTS-400-NO SB2588/02  CI 
Power 
February 20, 2008  5001ix-CTS-400-NO SB2588/03  CI 
6.3 Test set-up 
See annexe B   
6.4  Classification of EUT 
Devices with an active input power 
of P <75 W 
 
 
Balanced three-phase equipment and all other 
equipment, expect that stated in one of the 
following classes 
Class A  
 
 
Portable tools 
Class B  
 
Lightning equipment, including dimming devices 
Class C  
 
Equipment having an input current with a "special 
wave shape" as defined in figure 1 in the 
standard and an active input power, P 
≤ 600 W 
and motor driven with phase angle control 
Class D  
 
The power cord of the EUT is connected to the output of the test systems , Turn on the power of the 
EUT and use the test system to test the harmonic current level.Observation time: 150s 
If Harmonic current less than 0.6% of the input current measured under the test condition ,or less 
than 5mA, then whichever is greater,are disregarded. 