Harman Kardon DVD 49 (serv.man2) EMC - CB Certificate ▷ View online
- Page 25 of 42 -
Report
No.
98390
15.3.7
Terminals clamp conductors between metal and
have adequate pressure
have adequate pressure
N/A
Terminals designed to avoid conductor slipping
out when tightened or loosened
out when tightened or loosened
N/A
Terminals adequately fixed to avoid loosening
when the clamping is tightened or loosened and
stress on internal wiring is avoided
when the clamping is tightened or loosened and
stress on internal wiring is avoided
N/A
15.3.8
Terminals carrying a current more than 0,2 A:
contact pressure not transmitted by insulating
material except ceramic
contact pressure not transmitted by insulating
material except ceramic
N/A
15.3.9
Termination of non-detachable cords: wires
terminated near to each other
terminated near to each other
N/A
Terminals located and shielded: test with 8 mm
strand
strand
N/A
15.4
Devices forming a part of the mains plug
N/A
15.4.1
No undue strain on mains socket-outlets
No devices forming a part
of the mains plug.
of the mains plug.
N/A
15.4.2
Device complies with standard for dimensions of
mains plugs
mains plugs
N/A
15.4.3
Device has adequate mechanical strength
(tests a,b,c)
(tests a,b,c)
N/A
16
EXTERNAL FLEXIBLE CORDS
16.1
Mains cords sheathed type, complying with
IEC 60227 for PVC or IEC 60245 for synthetic
rubber cords ......................................................... :
IEC 60227 for PVC or IEC 60245 for synthetic
rubber cords ......................................................... :
Sheathed PVC cord
complying with IEC 60227
complying with IEC 60227
P
Non-detachable cords for Class I have
green/yellow core for protective earth
green/yellow core for protective earth
Class II apparatus
N/A
16.2
Mains cords conductors have adequate cross-
sectional area for rated current consumption of
the equipment
sectional area for rated current consumption of
the equipment
The cord is 0,75mm²,
within the current rating
within the current rating
P
16.3
a) Flexible cords not complying with 16.1, used for
interconnections between separate units of
equipment used in combination and carrying
hazardous live voltages, have adequate dielectric
strength
interconnections between separate units of
equipment used in combination and carrying
hazardous live voltages, have adequate dielectric
strength
No interconnecting cables
comprising hazardous live
conductors.
comprising hazardous live
conductors.
N/A
- Page 26 of 42 -
Report
No.
98390
b) Flexible cords not complying with 16.1,
withstand bending and mechanical stress (3.2 of
IEC 60227-2)
withstand bending and mechanical stress (3.2 of
IEC 60227-2)
Cord complying with 16.1.
N/A
16.4
Flexible cords used for connection between
equipment have adequate cross-sectional areas to
avoid temperature rise under normal and fault
conditions
equipment have adequate cross-sectional areas to
avoid temperature rise under normal and fault
conditions
Cords have adequate
cross-sectional areas to
avoid temperature rise under
normal and fault conditions.
cross-sectional areas to
avoid temperature rise under
normal and fault conditions.
P
16.5
Adequate strain relief on external flexible cords
Appliance inlet provided
N/A
Not possible to push cord back into equipment
N/A
Strain relief device unlikely to damage flexible
cord
cord
N/A
For mains cords of Class I equipment, hazardous
live conductors become taut before earth
conductor
live conductors become taut before earth
conductor
Class II apparatus.
N/A
16.6
Apertures for external flexible cord: no risk of
damage to the cord during assembly or movement
in use
damage to the cord during assembly or movement
in use
Appliance inlet provided
N/A
16.7
Transportable musical instruments and amplifiers
fitted with detachable cord set with appliance inlet
to IEC 60320-1
fitted with detachable cord set with appliance inlet
to IEC 60320-1
No such apparatus.
N/A
Transportable musical instruments and amplifiers
fitted with detachable cord sets or with means of
stowage to protect the cord
fitted with detachable cord sets or with means of
stowage to protect the cord
No such apparatus.
N/A
17
ELECTRICAL CONNECTIONS AND MECHANICAL FIXINGS
17.1
Torque test to table 20:
Screws fixing chassis to the
main enclosure tested.
main enclosure tested.
P
- screws into metal: 5 times
See attachment, Table to
EN/IEC 60065 7
EN/IEC 60065 7
th
edition.
P
- screws into non-metallic material: 10 times
N/A
17.2
Correct introduction into female threads in
non-metallic material
non-metallic material
No female threads in
non-metallic materials
non-metallic materials
N/A
17.3
Cover fixing screws: captive
Captivity not necessary
P
Non-captive fixing screws: no hazard when
replaced by a screw whose length is 10 times
its diameter
replaced by a screw whose length is 10 times
its diameter
Tested with screw with
10 times diameter.
10 times diameter.
P
- Page 27 of 42 -
Report
No.
98390
17.4
No loosening of conductive parts carrying a
current > 0,2 A
current > 0,2 A
Loosening is sufficiently
prevented
prevented
P
17.5
Contact pressure not transmitted through plastic
other than ceramic for connections carrying a
current > 0,2 A
other than ceramic for connections carrying a
current > 0,2 A
No contact pressure
transmitted through
insulating material.
transmitted through
insulating material.
P
17.6
Stranded conductors of flexible supply cords
carrying a current > 0,2 A with screw terminals not
consolidated by solder
carrying a current > 0,2 A with screw terminals not
consolidated by solder
Appliance inlet provided
N/A
17.7
Cover fixing devices other than screws have
adequate strength and their positioning is
unambiguous
adequate strength and their positioning is
unambiguous
No cover fixing devices
other than screws
other than screws
N/A
17.8
Fixing devices for detachable legs or stands
provided
provided
No detachable provided
N/A
17.9
Internal pluggable connections, affecting safety,
unlikely to become disconnected
unlikely to become disconnected
Connections complies,
checked by inspection
checked by inspection
P
18
MECHANICAL STRENGTH OF PICTURE TUBES AND PROTECTION AGAINST
THE EFFECTS OF IMPLOSION
THE EFFECTS OF IMPLOSION
Picture tube separately approved to IEC 61965:
No picture tube.
N/A
Picture tube separately approved to 18.1 ..........
N/A
18.1
Picture tubes > 16 cm intrinsically protected
N/A
Non-intrinsically protected tubes > 16 cm used
with protective screen
with protective screen
N/A
Protective film as part of implosion protection:
edges covered by enclosure
edges covered by enclosure
N/A
18.2
Intrinsically protected tubes: tests on 12 samples
N/A
18.2.1
Samples subject to ageing: 6
N/A
18.2.2
Samples subject to implosion test: 6
N/A
18.2.3
Samples subject to mechanical strength test
(steel ball): 6
(steel ball): 6
N/A
18.3
Non-intrinsically protected tubes tested to 18.3
N/A
- Page 28 of 42 -
Report
No.
98390
19
STABILITY AND MECHANICAL HAZARDS
Mass of the equipment exceeding 7 kg ............. :
Weight: 3,3 kg
⎯
Apparatus intended to be fastened in place –
suitable instructions
suitable instructions
N/A
19.1
Test on a plane, inclined at 10
o
to the horizontal
N/A
19.2
100 N force applied vertically downwards
N/A
19.3
100 N force, or 13% of weight, applied horizontally
to point of least stability.
to point of least stability.
< 25 kg, < 1M
N/A
19.4
Edges or corners not hazardous
There is no hazardous
edges or corners when the
apparatus is operating in
normal position
edges or corners when the
apparatus is operating in
normal position
P
19.5
Glass surfaces (exc.laminated) with an area
exceeding 0,1 m² or maximum dimension
> 450 mm, pass the test of 19.5.1
exceeding 0,1 m² or maximum dimension
> 450 mm, pass the test of 19.5.1
No glass surface.
N/A
19.6
Wall or ceiling mountings adequate
No wall or ceiling
mountings.
mountings.
N/A
20
RESISTANCE TO FIRE
20.1
Electrical components and mechanical parts
P
a) Exemption for components contained in an
enclosure of material V-0 to IEC
enclosure of material V-0 to IEC
60695-11-10
with
openings not exceeding 1 mm in width
.
N/A
b) Exemption for small components as defined in
20.1
20.1
PCB is of flammability
class V-0 and exception is
made for small components
class V-0 and exception is
made for small components
P
20.1.1 Electrical
components
meet the requirements of
Clause 14 or 20.1.4
Electrical components
comply with flammability
requirements in clause 14.
comply with flammability
requirements in clause 14.
P
20.1.2
Insulation of internal wiring working at voltages
> 4 Kv or leaving an internal fire enclosure,
> 4 Kv or leaving an internal fire enclosure,
or
located within the areas mentioned in Table 21,
not contributing to the spread of fire
No wires working at
voltages > 4kV or leaving
an internal fire enclosure
voltages > 4kV or leaving
an internal fire enclosure
N/A
Click on the first or last page to see other DVD 49 (serv.man2) service manuals if exist.