Harman Kardon DVD 39 (serv.man3) EMC - CB Certificate ▷ View online
Anam Electronics Co., Ltd.
Page 9 of 17
DVD 39/230
EMC Test Report
Reference No.:NK2HE1078
6. Electrostatic Discharges
6.1 Test Procedure
A ground reference plane was located on the floor, and connected to earth via a low impedance
connection. The return cable of the ESD generator was connected to the reference plane. In case of
a floor standing equipment, EUT was placed on the reference plane on 0.1 m of insulating support.
In case of table-top equipment, EUT was placed on a wooden table 0.8 m above the reference plane.
A horizontal coupling plane(HCP) of 1.6 m x 0.8 m was placed on the table, and connected to the
reference plane via a cable with a 470 ㏀ resistor located in each end(0.5 mm insulating support between
EUT and HCP). In both cases a vertical coupling plane (VCP) of 0.5 m x 0.5 m was located 0.1 m from
the EUT’s sides. The VCP was connected to the reference plane in the same matter as the HCP. The
test was done by applying contact and air discharges to the EUT itself, and contact discharges to the HCP
and VCP. When applying the discharges to the HCP, the tip of the generator was located at the front edge
of each HCP opposite the center point of the EUT, at 0.1 m distance. When applying the discharges to the
VCP the tip of the generator was located at the middle edge of the VCP. The VCP was located 0.1 m from
each side of the EUT. Contact discharges up to ±4 kV were applied to various points of the EUT at
conductive surfaces, and to the HCP/VCP. Air discharges up to ±8 kV were applied to various points of
the EUT at non-conductive surfaces.
Ungrounded equipment, or ungrounded part(s) of equipment, cannot discharge itself similarly to class I
mains-supplied equipment. If the charge is not removed before the next ESD pulse is applied, it is
possible that the EUT or part(s) of the EUT be stressed up to twice the intended test voltage. Therefore,
double-insulated equipment could be charged at an unrealistically high charge, by accumulating several
ESD discharges on the capacitance of the class II insulation, and then discharge at the breakdown voltage
of the insulation with a much higher energy. In the case of class II & III equipment, to avoid of
unrealistically high charge, it is possible to ionize “using ionizer” before each discharge.
Instrumentation used during this session:
Instruments Manufacturer
Model
Serial number
Due to Calibration
ESD Simulator
Noiseken
ESS-2000
0199C02406
2008.12
Discharge Gun
Noiseken
TC-815P
1199C02485
2008.12
6.2 Test Parameters
Port:
Enclosure
Basic Standard:
EN 61000-4-2:1995+A1:1998+A2:2001
Performance Criteria: B
Performance Results :
A
Test Engineer:
Jin-ha, Ko
Test Level
Air Discharge:
± 4, 8 kV
Contact
Discharge:
± 2, 4 kV
Anam Electronics Co., Ltd.
Page 10 of 17
DVD 39/230
EMC Test Report
Reference No.:NK2HE1078
6.3 Test Log
Comment/Performance
Any degradation was not detected in the evaluation of picture quality.
Result
Compliant
Point Voltage
Coupling
Result
(Pass/Fail)
HCP, VCP
± 2, 4 kV
Contact Discharge
Pass
RCA Jacks
± 2, 4 kV
Contact Discharge
Pass
Enclosure
± 2, 4 kV
Contact Discharge
Pass
Screws
± 2, 4 kV
Contact Discharge
Pass
Remote Jacks
± 4, 8 kV
Air Discharge
Pass
Front Panel
± 4, 8 kV
Air Discharge
Pass
Buttons
± 4, 8 kV
Air Discharge
Pass
Anam Electronics Co., Ltd.
Page 11 of 17
DVD 39/230
EMC Test Report
Reference No.:NK2HE1078
7. Radio-frequency, Electromagnetic Field Keyed Carrier Immunity test
7.1 Test Procedure
The tests were performed at 3 m distance in an anechoic chamber.
For floor-standing equipment, the EUT was mounted non-conducting support 0.1 m above the
supporting plane. For tabletop equipment, the EUT was located on a wooden table 0.8 m above the floor.
The EUT was exposed to the field from different angles, normally 0°, 90°, 180°, 270°
and at both horizontal and vertical polarization(antenna height 1.75 m)
A signal level of 3 V/m, duty cycle 1/8 pulse modulated with a 217 Hz sine wave was applied in the
frequency range 900 MHz. During the test the 1 kHz unwanted noise level comes from the speaker was
detected using microphone and selected level meter
Instrumentation used during this session:
Instruments Manufacturer
Model
Serial number
Due to Calibration
Signal Generator
R & S
SMY01
830766/032
2008.03
Function Generator
HP
33120A
US36042890
2008.12
Power Amplifier
Noiseken
NA25MF1G2010C
A00518
2008.10
Power Sensor
HP
8482A
US37293322
2008.03
Power Sensor
HP
8482A
US37293323
2008.03
Power Meter
HP
E4419B
GB39511164
2008.03
Biconical log
Antenna
Antenna
ARA LPB-2520/A
1180 2008.02
Position Controller
Seo-Young EMC
N/A
N/A
N/A
Turntable Seo-Young
EMC
N/A
N/A N/A
7.2 Test Parameters
Port:
Enclosure
Basic Standard:
EN 61000-4-3:2002+A1:2002
Performance Criteria: A
Performance Results :
A
Test Engineer:
Jin-ha, Ko
Dwell Time:
120 s
Modulation:
Duty Cycle 1/8 PM @ 217 Hz
Frequency Range:
900 MHz
Test Level:
3 V/m
Anam Electronics Co., Ltd.
Page 12 of 17
DVD 39/230
EMC Test Report
Reference No.:NK2HE1078
7.3 Test Log
Frequency
Range (MHz)
Position
(Angle)
Polarity
(H/V)
Field Strength
(V/m)
Modulation
Result
(Pass/Fail)
900 Front H
3 Duty Cycle 1/8 PM@217Hz
Pass
900 Rear H
3 Duty Cycle 1/8 PM@217Hz
Pass
900 Right H
3 Duty Cycle 1/8 PM@217Hz
Pass
900
Left H
3 Duty Cycle 1/8 PM@217Hz
Pass
900
Front V
3 Duty Cycle 1/8 PM@217Hz
Pass
900
Rear V
3 Duty Cycle 1/8 PM@217Hz
Pass
900
Right V
3 Duty Cycle 1/8 PM@217Hz
Pass
900
Left V
3 Duty Cycle 1/8 PM@217Hz
Pass
Comment/Performance
The criterion of compliance with the requirement is satisfied with a wanted to unwanted audio signal ratio of
≥ 40 dB at a wanted audio signal level of 500 mV.
≥ 40 dB at a wanted audio signal level of 500 mV.
Any degradation was not detected in the evaluation of picture quality.
Result