EMC Test Report
 
         
Reference No.:NK2HE1078 
6. Electrostatic Discharges 
 
6.1 Test Procedure 
     
 
A ground reference plane was located on the floor, and connected to earth via a low impedance   
      connection. The return cable of the ESD generator was connected to the reference plane. In case of     
      a floor standing equipment, EUT was placed on the reference plane on 0.1 m of insulating support. 
      In case of table-top equipment, EUT was placed on a wooden table 0.8 m above the reference plane. 
   A horizontal coupling plane(HCP) of 1.6 m x 0.8 m was placed on the table, and connected to the   
reference plane via a cable with a 470 ㏀  resistor located in each end(0.5 mm insulating support between   
EUT and HCP). In both cases a vertical coupling plane (VCP) of 0.5 m x 0.5 m was located 0.1 m from   
the EUT’s sides. The VCP was connected to the reference plane in the same matter as the HCP. The   
test was done by applying contact and air discharges to the EUT itself, and contact discharges to the HCP   
and VCP. When applying the discharges to the HCP, the tip of the generator was located at the front edge   
of each HCP opposite the center point of the EUT, at 0.1 m distance. When applying the discharges to the   
VCP the tip of the generator was located at the middle edge of the VCP. The VCP was located 0.1 m from   
each side of the EUT. Contact discharges up to  ±4 kV were applied to various points of the EUT at   
conductive surfaces, and to the HCP/VCP. Air discharges up to  ±8 kV were applied to various points of   
the EUT at non-conductive surfaces. 
Ungrounded equipment, or ungrounded part(s) of equipment, cannot discharge itself similarly to class I 
mains-supplied equipment. If the charge is not removed before the next ESD pulse is applied, it is   
possible that the EUT or part(s) of the EUT be stressed up to twice the intended test voltage. Therefore, 
double-insulated equipment could be charged at an unrealistically high charge, by accumulating several 
ESD discharges on the capacitance of the class II insulation, and then discharge at the breakdown voltage 
of the insulation with a much higher energy. In the case of class II & III equipment, to avoid of   
unrealistically high charge, it is possible to ionize “using ionizer” before each discharge. 
Instrumentation used during this session: 
Instruments Manufacturer 
Model 
Serial number 
Due to Calibration
ESD Simulator   
Noiseken 
ESS-2000 
0199C02406 
2008.12 
Discharge Gun 
Noiseken 
TC-815P 
1199C02485 
2008.12 
 
6.2 Test Parameters 
 
Port: 
Enclosure 
 
 
Basic Standard: 
EN 61000-4-2:1995+A1:1998+A2:2001 
Performance Criteria:  
Performance Results : 
Test Engineer: 
Jin-ha, Ko 
 
 
Test Level 
Air Discharge: 
± 4, 8 kV 
 
 Contact 
Discharge: 
± 2, 4 kV 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
Anam Electronics Co., Ltd. 
                                      Page 10 of 17 
DVD 39/230 
EMC Test Report
 
         
Reference No.:NK2HE1078 
6.3 Test Log 
 
 
 
 
     
Comment/Performance 
Any degradation was not detected in the evaluation of picture quality. 
Result 
    Compliant 
Point Voltage 
Coupling 
Result 
(Pass/Fail) 
HCP, VCP 
± 2, 4 kV 
Contact Discharge 
Pass 
RCA Jacks 
± 2, 4 kV 
Contact Discharge 
Pass 
Enclosure 
± 2, 4 kV 
Contact Discharge 
Pass 
Screws 
± 2, 4 kV 
Contact Discharge 
Pass 
Remote Jacks 
± 4, 8 kV 
Air Discharge 
Pass 
Front Panel 
± 4, 8 kV 
Air Discharge 
Pass 
Buttons 
± 4, 8 kV 
Air Discharge 
Pass 
 
Anam Electronics Co., Ltd. 
                                      Page 11 of 17 
DVD 39/230 
EMC Test Report
 
         
Reference No.:NK2HE1078 
7. Radio-frequency, Electromagnetic Field Keyed Carrier Immunity test 
 
7.1 Test Procedure 
 
The tests were performed at 3 m distance in an anechoic chamber.   
        For floor-standing equipment, the EUT was mounted non-conducting support 0.1 m above the 
        supporting plane. For tabletop equipment, the EUT was located on a wooden table 0.8 m above the floor. 
        The EUT was exposed to the field from different angles, normally 0°, 90°, 180°, 270° 
        and at both horizontal and vertical polarization(antenna height 1.75 m) 
        A signal level of 3 V/m, duty cycle 1/8 pulse modulated with a 217 Hz sine wave was applied in the   
frequency range 900 MHz. During the test the 1 kHz unwanted noise level comes from the speaker was   
detected using microphone and selected level meter 
        Instrumentation used during this session:
   
Instruments Manufacturer 
Model 
Serial number 
Due to Calibration
Signal Generator 
R & S 
SMY01 
830766/032 
2008.03 
Function Generator
HP 
33120A 
US36042890 
2008.12 
Power Amplifier 
Noiseken 
NA25MF1G2010C
A00518 
2008.10 
Power Sensor 
HP 
8482A 
US37293322 
2008.03 
Power Sensor 
HP 
8482A 
US37293323 
2008.03 
Power Meter 
HP 
E4419B 
GB39511164 
2008.03 
Biconical log 
Antenna 
ARA LPB-2520/A 
1180 2008.02 
Position Controller 
Seo-Young EMC
N/A 
N/A 
N/A 
Turntable Seo-Young 
EMC
N/A 
N/A  N/A 
 
7.2 Test Parameters
 
 
 
Port: 
Enclosure 
 
 
Basic Standard: 
EN 61000-4-3:2002+A1:2002 
 
Performance Criteria:  
Performance Results :
Test Engineer: 
Jin-ha, Ko 
 
 
Dwell Time: 
120 s 
Modulation: 
Duty Cycle 1/8 PM @ 217 Hz
Frequency Range: 
900 MHz 
Test Level: 
3 V/m 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
Anam Electronics Co., Ltd. 
                                      Page 12 of 17 
DVD 39/230 
EMC Test Report
 
         
Reference No.:NK2HE1078 
7.3 Test Log 
 
Frequency  
Range (MHz) 
Position 
(Angle) 
Polarity 
(H/V) 
Field Strength
(V/m) 
Modulation 
Result 
(Pass/Fail)
900 Front H 
3 Duty Cycle 1/8 PM@217Hz 
Pass 
900 Rear H 
3 Duty Cycle 1/8 PM@217Hz 
Pass 
900 Right H 
3 Duty Cycle 1/8 PM@217Hz 
Pass 
900 
Left H 
3 Duty Cycle 1/8 PM@217Hz 
Pass 
900 
Front V 
3  Duty Cycle 1/8 PM@217Hz 
Pass 
900 
Rear V 
3  Duty Cycle 1/8 PM@217Hz 
Pass 
900 
Right V 
3  Duty Cycle 1/8 PM@217Hz 
Pass 
900 
Left V 
3 Duty Cycle 1/8 PM@217Hz 
Pass 
       
Comment/Performance 
The criterion of compliance with the requirement is satisfied with a wanted to unwanted audio signal ratio of   
≥ 40 dB at a wanted audio signal level of 500 mV. 
Any degradation was not detected in the evaluation of picture quality. 
Result 
    Compliant 