Reference No. : 54120801I                                                                                                                        Page 4
 
◀  Anam EMC Test Laboratory  ▶
 
 
1. CLIENT INFORMATION 
 
    The EUT has been tested by request of: 
* Company 
: Harman Consumer Group 
 
8500 Balboa Blvd., Northridge, CA 91329, USA 
* Contact Person 
: Mr. Patrick Zarrabi 
* Tel. 
: +1-818-895-8161 
 
2. EQUIPMENT UNDER TEST (EUT) 
2.1. Identification of the EUT 
*Equipment 
: DVD Player 
*Model No. 
: DVD39/230 
*Brand Name 
: Harman/Kardon 
*Serial No. 
: N/A 
 
*Manufacturer 
 (China) 
 
: DongGuan LiaoBu Anam Electronics. 
  Xin Cheng Management Area, LiaoBu Town, 
  DongGuan City, Guang Dong province, China 
  Fax: +86-769-321 6338, Tel: +86-769-332 6888 
 
*Power Rating 
 
: AC 220-230V, 50/60Hz, 25W 
 
*External signal 
 
 In/Out terminal 
 
: Audio out L/R, 6ch Audio out, Coaxial, Optical, 
: Audio out 
: HDMI 
: Video out(S-Video, Video, Component) 
: Remote IN/OUT 
 
             
 
2.2. Additional Information about the EUT 
The EUT consists of the following Subsystems/Modules/Parts: N/A 
 
The test have been performed on the EUT provided with the following 
modifications : None. 
 
 
 
 
 
 
 
 
Reference No. : 54120801I                                                                                                                        Page 5
 
◀  Anam EMC Test Laboratory  ▶
 
 
3. TEST SPECIFICATIONS 
 
   3.1. Standards 
 
*EN55013 (2001)&+A2(2006) : 
Sound and Television broadcast receivers and Associated equipment 
-Radio Disturbance characteristics - Limits and methods of measurement. 
 *EN61000-3-2 
(2000): 
Part 3-2: Limits- Limits for harmonic current emissions 
 
(Equipment input current  ≤16A per phase) 
 
*EN61000-3-3 (1995 +Amd.1;2001): 
 
 Part 3-3: Limits- Limitation of voltage changes, voltage fluctuations and 
flicker in public low-voltage supply systems for equipment with rated 
current  ≤16A. 
      3.2. Additions, deviations and exclusions from standard 
 
No additions, deviations or exclusions have been made from standard. 
 
      3.3. Purpose of the test: 
 
To determine whether the EUT fulfils the EMC-emission requirements of the   
 
Standards stated in section 3.1. 
 
      3.4. Mode of operation during the test 
 
The EUT was operated in such a way as to deliver one-eighth on the non-clipped 
 
output power to the rated load impedance using the sinusoidal of 1 ㎑ & color- 
       bar. 
 
The EUT was set to the mode of Tuner. 
 
4. TEST SUMMARY 
 
The results in this report apply only to sample(s) tested: 
Test item 
Passed 
the test 
Note 
Mains terminal disturbance voltage 
Yes 
 
Disturbance Power 
Yes 
 
Harmonics Yes 
 
Flicker Yes 
 
 
The equipment does comply with the requirements. 
 
For the measurement data, see Annex. 
 
 
 
Reference No. : 54120801I                                                                                                                        Page 6
 
◀  Anam EMC Test Laboratory  ▶
 
 
5. MAINS TERMINAL DISTURBANCE VOLTAGE IN THE FREQUENCY 
RANGE 0.15MHz TO 30MHz
 
 
   5.1. Operating environment 
Temperature 
: 25℃ 
Relative humidity  : 55 % 
 
5.2. Test set-up and procedure 
 
 
 
The mains terminal disturbance voltage was measured with the EUT in a 
Screened room. The EUT was placed on a non-metallic table by 0.8m above   
the metallic grounded floor and 0.4m from the reference ground panel (RGP) 
wall. The distance to other metallic surfaces was at least 0.8m. 
The EUT was tested with the outer conductor of the antenna input connected 
as well as not connected to the ground terminal of the AMN. 
The level of the test signal was 1KHz sine wave and color bar from DVD. 
Amplitude measurements were performed with a quasi-peak detector and, 
If required, with an average detector. 
 
5.3. Measurement uncertainty 
 
Mains terminal disturbance voltage, quasi-peak detection:  ±2.0dB 
 
Mains terminal disturbance voltage, average detection      :  ±2.0dB 
 
The measurement uncertainty describes the overall uncertainty of the given 
 
measured value during the operation of the EUT in the above-mentioned way. 
 
 
 
 
 
 
Reference No. : 54120801I                                                                                                                        Page 7
 
◀  Anam EMC Test Laboratory  ▶
 
 
 
5.4. Test instrument 
Equipment 
Manufacturer 
Type No. 
Serial No. 
Test site 
Shielded room 
Measurement 
                      Receiver 
R & S 
ESCI 
100348 
R & S 
ESH3-Z5 
844249/020 
Artificial mains 
                      Network  EMCO 3825/2 90101718 
Test DVD 
 
TDV-540 
N/A 
   
 
* R & S: Rohde & Schwarz 
 
5.5. Test protocol 
 
 
Date: January 21, 2008 
 
Ungrounded at the Signal GND Terminal on the Rear Enclosure. 
 
An overview sweep performed with peak detector is included in the test 
report as Annex A. 
Quasi-peak (㏈㎶) Average 
(㏈㎶) 
Disturbance value 
Disturbance value 
Mode 
Freq. 
(㎒) 
Limit 
Line 1 
Line 2 
Limit 
Line 1 
Line 2 
DVD .269 62.7 49.5 48.8 52.7 38.8 38.2 
Play 3.834 56.0 41.2 35.8 46.0 33.1 28.6 
 
 
 
 
 
 
 
 
 
 
 
The equipment does comply with the requirements. 
 
For the measurement data, see Annex A (2 Copies). 
 
 
 
 
 
 
 
 
 
 
 
 
 
Page of 73