Harman Kardon DVD 31 (serv.man12) EMC - CB Certificate ▷ View online
Test report no. JSH0311243-001
Page 4 of 19
1.CLIENT INFORMATION
The EUT has been tested by request of:
Company:
Harman Consumer International.
2, Route de Tours 72500 chateau du Loir France.
Name of contact:
Mr. Wang Gui Teng
Telephone: 86-0596 7653999-8516
Telefax: 86-0596 7666248
2.EQUIPMENT UNDER TEST(EUT)
2.1 Identification of the EUT
Equipment: DVD Player
Type/model: DVD31
Manufacture:
WANLIDA GROUP CO., LTD.
Address
NO. 618, JIAHE ROAD, XIAMEN, FUJIAN, 361006, P. R.
CHINA.
CHINA.
Country of origin: China
Rating: 100V-240V~, 50/60Hz, 20W
2.2 Additional information about the EUT
Some thing about the EUT models
The EUT has only one model DVD31. All necessary tests are performed on the model.
The EUT consists of the following subsystems/modules/parts: None
2.2 Additional information about the EUT
Some thing about the EUT models
The EUT has only one model DVD31. All necessary tests are performed on the model.
The EUT consists of the following subsystems/modules/parts: None
System Type Serial number
The EUT was tested with the following cables, type, length:
Mains cable 1.8 m
The tests have been performed on the EUT provided with the following modification: None
2.3 Peripheral equipment
Defined as equipment needed for correct operation of the EUT, but not considered as tested: None
System Type Serial number
Defined as equipment needed for correct operation of the EUT, but not considered as tested: None
System Type Serial number
Test report no. JSH0311243-001
Page 5 of 19
3.TEST SPECIFICATIONS
3.1 Standards
EN55013:2001: Limits and methods of measurement of radio disturbance characteristics of broadcast
receivers and associated equipment.
EN 61000-3-2 (2000): Limits for harmonic current emissions (equipment input current up to and
including 16A per phase.)
EN 61000-3-3 (1995)+A1: 2001: limitation of voltage fluctuation and flicker in low voltage supply
systems for equipment with rated current up to and including 16A
3.2 Additions, deviations and exclusions from standards
No additions, deviations or exclusions have been made from standard.
3.3 Purpose of the test
Purpose of test: To determine whether the equipment under test fulfils the EMC-emission requirement
of the standards stated section 3.1
3.4 Mode of operation during the test
The EUT was set to achieve maximum emission.
4.TEST SUMMARY
The results in this report apply only to sample tested:
TEST ITEM
PASSED THE TEST
NOTE
Mains terminal continuous disturbance voltage
Pass
Continuous disturbance power
Pass
Antenna Terminal disturbance voltage
NA
Radiated emission test
NA
Harmonics Pass
Voltage fluctuation-Flicker
Pass
Notes: 1: NA =Not Applicable
2: Margin to the limit is within the uncertainty interval of the measured value.
3: Limit is exceeded with a margin less than the uncertainty interval of the measured value.
Test report no. JSH0311243-001
Page 6 of 19
5.MAINS TERMINAL CONTINUOUS DISTURBANCE VOLTAGE
5.1 Test result
Pass Fail Not applicable
5.2 Operating environment
Temperature: 22 °C
Relative Humidity: 48 %
5.3 Test set-up and test procedure
5.1 Test result
Pass Fail Not applicable
5.2 Operating environment
Temperature: 22 °C
Relative Humidity: 48 %
5.3 Test set-up and test procedure
The mains terminal disturbance voltage was measured with the equipment under test(EUT) in a
screened room.
The EUT was placed on a 0.4m high non-metallic table above a 2m by 2m in size ground reference
plane(GRP),and keeps a distance of at least 0.8m from any of the other metallic surface.
The EUT was connected to an artificial mains network and at a distance of 0.8m from it. The mains
lead excess 0.8m was bundled to 0.3m or 0.4m parallel to the lead.
Amplitude measurements were performed with a quasi-peak detector and, if required, with an average
detector.
5.4 Measurement uncertainty
Mains terminal disturbance voltage, quasi-peak detection: + 2,0 dB
Mains terminal disturbance voltage, average detection: + 2,0 dB
The measurement uncertainty describes the overall uncertainty of the given measured value during the
operation of the EUT in the above mentioned way.
Measurement uncertainty is calculated in accordance with WECC 19-1990.
The measurement uncertainty is given with a confidence of 95%
AC
POWER
SOURCE
POWER
SOURCE
TRANSFORMER
AMN
TEST RECEIVER
EUT
Test report no. JSH0311243-001
Page 7 of 19
5.5 Test instrumentation
Equipment Manu. Type Serial no.
Test site: Shielded room
Measurement receiver R&S ESCS 30
Artificial mains network R&S ESH3-Z5
R&S= Rohde & Schwarz
5.6 Test protocol
DVD Mode
DVD Mode
Frequency
/MHz
Quasi-Peak
Disturbance Permitted
Level limit
/dB(uV) /dB(uV)
Level limit
/dB(uV) /dB(uV)
Average
Disturbance Permitted
level limit
/dB(uV) /dB(uV)
level limit
/dB(uV) /dB(uV)
0,16 * 65.46 * 55.46
0,24 * 62.10 * 52.10
0,55 * 56.00 * 46.00
1,00 * 56.00 * 46.00
1,40 * 56.00 * 46.00
0,24 * 62.10 * 52.10
0,55 * 56.00 * 46.00
1,00 * 56.00 * 46.00
1,40 * 56.00 * 46.00
2.0 * 56.00 * 46.00
3,50 * 56.00 * 46.00
6,00 * 60.00 * 50.00
6,00 * 60.00 * 50.00
10,00
* 60.00 * 50.00
22,00
* 60.00 * 50.00
30,00
* 60.00 * 50.00
Notes: * means the disturbance voltage level 10dB lower than the limit.