Harman Kardon DVD 31 (serv.man12) EMC - CB Certificate ▷ View online
Test report no. JSH0311243-001
Page 16 of 19
10.VOLTAGE FLUCTUATIONS-FLICKER
10.1 Test result
Pass Fail Not applicable
10.2 Operating environment
Temperature: °C
Relative Humidity: %
10.3 Test set-up and test procedure
The product no means to generate voltage fluctuation higher than the relevant limit, therefore, it is
deemed to fulfill the requirements according to EN61000-3-3 without test.
10.4 Test instrumentation
Equipment Manu. Type Serial no.
Harmonic & flicker test system California Instruments 500lix-CTS-400
Test report no. JSH0311243-001
Page 17 of 19
10.5 Test protocol
The tested object operated under the operating condition specified in EN 61000-3-3:1995.The
following limits apply according to EN 61000-3-3:1995.
--the relative steady-state voltage change ,dc, shall not exceed 3%;
--the maximum relative voltage change, dmax, shall not exceed 4%
--the value of d(t) during a voltage change shall not exceed 3% for more than 200ms;
-- for voltage changes caused by manual switching or occur less frequently than once per hour, The Pst
and Plt requirements shall not be applicable. three requirements related to voltages shall be applicable
with the previously mentioned voltage values, multiplied by a factor of 1.33.
The following tables (Table ) are those measured by an automatic measuring system.
dc
dmax d(t) Pst
Plt
Limits 3.00%/3.99%*
4.00%/5.32%*
3%/3.99*
200ms 1.000 0.650
Measured
* For voltage changes caused by manual switching the voltage values multiplied by a factor of
1.33
Test report no. JSH0311243-001
Page 18 of 19
Appendix I Photograph of EUT
Test report no. JSH0311243-001
Page 19 of 19
Click on the first or last page to see other DVD 31 (serv.man12) service manuals if exist.