Harman Kardon DVD 29 (serv.man3) EMC - CB Certificate ▷ View online
- Page 14 of 40 -
Report
No.
89538
TRF No: IEC/EN 60065G
IEC/EN 60065
Clause
Requirement – Test
Result - Remark
Verdict
b) Test hook of fig. 4 for 10 s (20 N)
Test with test hook results
in no hazard.
in no hazard.
P
c) 30 mm diameter test tool for 5 s (100 or 250 N) :
Tested with 100N results in
no damage.
no damage.
P
9.2
No hazard after removing a cover by hand
No cover removable by
hand
hand
N/A
10 INSULATION
REQUIREMENTS
10.1
I
nsulation resistance (MΩ) at least 2 MΩ min. after
surge test for basic and 4 MΩ min. for reinforced
insulation ................................................................. :
insulation ................................................................. :
> 100 M
Ω, after surge test P
10.2
Humidity treatment 48 h or 120 h ........................... :
120 h (40
°C).
No impairment
P
10.3
Insulation resistance and dielectric strength between
mains teminals
mains teminals
(see appended table)
P
Insulation Resistance and dielectric strength across
BASIC or SUPPLEMENTARY insulation (Class 1)
BASIC or SUPPLEMENTARY insulation (Class 1)
(see appended table)
P
Insulation resistance and dielectric strength across
REINFORCED insulation (Class II)
REINFORCED insulation (Class II)
(see appended table)
P
- Page 15 of 40 -
Report
No.
89538
TRF No: IEC/EN 60065G
IEC/EN 60065
Clause
Requirement – Test
Result - Remark
Verdict
11 FAULT
CONDITIONS
P
11.1
No shock hazard under fault condition
No electric shock hazard.
P
11.2
Heating under fault condition
See attachment, Tables to
EN/IEC 60065 7
EN/IEC 60065 7
th
edition
P
No hazard from softening solder
No softening of solder
P
Flames extinguish within 10 seconds
No flames
P
Soldered terminations not used as protective
mechanism
mechanism
No protective mechanism
P
11.2.1
Measurement of temperature rises
See attachment, Tables to
EN/IEC 60065 7
EN/IEC 60065 7
th
edition
P
11.2.2
Temperature rise of accessible parts
See attachment, Tables to
EN/IEC 60065 7
EN/IEC 60065 7
th
edition
P
11.2.3
Temperature rise of parts, other than windings,
providing electrical insulation
providing electrical insulation
See attachment, Tables to
EN/IEC 60065 7
EN/IEC 60065 7
th
edition
P
Temperature rise of printed circuit boards (PCB)
exceeding the limits of table 3 by max. 100 K for max.
5 min
exceeding the limits of table 3 by max. 100 K for max.
5 min
No exceeding the limits of
Table 3.
Table 3.
P
a) Temperature rise of printed circuit boards (PCB) to
20.1.3, exceeding the limits of table 3 by not more
than 100 K for an area not greater than 2 cm²
20.1.3, exceeding the limits of table 3 by not more
than 100 K for an area not greater than 2 cm²
No area where temperature
exceeds 100K above limits
exceeds 100K above limits
N/A
b) Temperature rise of printed circuit boards (PCB) to
20.1.3 up to 300 K for an area not greater than 2 cm²
for a maximum of 5 min
20.1.3 up to 300 K for an area not greater than 2 cm²
for a maximum of 5 min
No area where temperature
exceeds 300K above limits
exceeds 300K above limits
N/A
Meets all the special conditions if conductors on
printed circuit boards are interrupted
printed circuit boards are interrupted
No conductors are
interrupted/peeled/loosened
during fault conditions
N/A
Class I protective earthing maintained
Class II equipment
N/A
11.2.4
Temperature rise of parts acting as a support or
mechanical barrier
mechanical barrier
Temperature rises are
within the limits.
within the limits.
P
11.2.5
Temperature rise of windings
See attachment, Tables to
EN/IEC 60065 7
EN/IEC 60065 7
th
edition
P
11.2.6
Temperature rise of parts not subject to the limits of
11.2.1 to 11.2.5
11.2.1 to 11.2.5
No excessive temperature
observed/measured on
other parts.
See attachment, Tables to
EN/IEC 60065 7th edition
observed/measured on
other parts.
See attachment, Tables to
EN/IEC 60065 7th edition
P
- Page 16 of 40 -
Report
No.
89538
TRF No: IEC/EN 60065G
IEC/EN 60065
Clause
Requirement – Test
Result - Remark
Verdict
12 MECHANICAL
STRENGTH
12.1.1
Bump test where mass >7 kg
Mass: 3,3kg
N/A
12.1.2 Vibration
test
Assessed to be satisfactory
constructed
constructed
P
12.1.3
Impact hammer test
No damage in the sense of
this standard
this standard
P
Steel ball test
No damage in the sense of
this standard
this standard
P
12.1.4
Drop test for portable apparatus where mass < 7 kg
Not portable apparatus
N/A
12.1.5
Thermoplastic enclosures strain relief test
Tested, 70ºC, 7h
P
12.2
Fixing of knobs, push buttons, keys and levers
Normal use will not impair
the protection against
electric shock.
the protection against
electric shock.
P
12.3
Remote controls with hazardous live parts
No cable connected
remote control devices.
remote control devices.
N/A
12.4
Drawers (pull test 50 N, 10 s)
No drawers
N/A
12.5
Antenna coaxial sockets providing isolation
No antenna.
N/A
12.6
Telescoping or rod antennas construction
No telescoping or rod
antennas
antennas
N/A
12.6.1
Telescoping or rod antennas securement
N/A
13
CLEARANCE AND CREEPAGE DISTANCES
13.1
Clearances in accordance with 13.3
See attachment, Table to
EN/IEC 60065 7
EN/IEC 60065 7
th
edition.
P
Creepage distances in accordance with 13.4
See attachment, Table to
EN/IEC 60065 7
EN/IEC 60065 7
th
edition.
P
13.2
Determination of operating voltage
Conventional switching
transformer used.
Upper rated supply voltage
applied in determining the
operating voltage
transformer used.
Upper rated supply voltage
applied in determining the
operating voltage
P
13.3 Clearances
2N for internal parts and
30N for enclosures are
considered when
determining clearances.
30N for enclosures are
considered when
determining clearances.
P
- Page 17 of 40 -
Report
No.
89538
TRF No: IEC/EN 60065G
IEC/EN 60065
Clause
Requirement – Test
Result - Remark
Verdict
13.3.1 General
P
13.3.2
Circuits conductively connected to the mains comply
with table 8 and, where applicable, table 9
with table 8 and, where applicable, table 9
See attachment, Tables to
EN/IEC 60065 7
EN/IEC 60065 7
th
edition
P
13.3.3
Circuits not conductively connected to the mains
comply with table 10
comply with table 10
No hazardous secondary
voltages
voltages
N/A
13.3.4
Measurement of transient voltages
No measurement of
transient voltages
transient voltages
N/A
13.4 Creepage
distances
CTI > 100
See attachment, Tables to
EN/IEC 60065 7
See attachment, Tables to
EN/IEC 60065 7
th
edition
P
Creepage distances greater than table 11 minima
Not applicable
N/A
13.5 Printed
boards
N/A
13.5.1
Clearances and creepage distances between
conductors on printed circuit boards, one of which
may be conductively connected to the mains, as in
fig. 10
conductors on printed circuit boards, one of which
may be conductively connected to the mains, as in
fig. 10
No such PCB used
N/A
13.5.2
Type B coated printed circuit boards complying with
IEC 60664-3 (basic insulation only)
IEC 60664-3 (basic insulation only)
No type B coated printed
circuit boards
circuit boards
N/A
13.6
Conductive parts along uncemented joints
clearances and creepage distances comply with 13.3
and 13.4
clearances and creepage distances comply with 13.3
and 13.4
Jointed insulation not applied
N/A
Conductive parts along reliably cemented joints
comply with 8.8
comply with 8.8
N/A
Temperature cycle test and dielectric strength test
N/A
13.7
Enclosed, enveloped or hermetically sealed parts:
not conductively connected to the mains: clearances
and creepage distances as in table 12
not conductively connected to the mains: clearances
and creepage distances as in table 12
No enclosed, enveloped or
hermetically sealed parts
hermetically sealed parts
N/A
13.8
Parts filled with insulating compound, meeting the
requirements of 8.8
requirements of 8.8
Approved optocouplers,
see list of critical components.
see list of critical components.
P
Click on the first or last page to see other DVD 29 (serv.man3) service manuals if exist.