 Report 
No. 
89538 
 
TRF No:  IEC/EN 60065G 
 
IEC/EN 60065 
Clause 
Requirement – Test 
Result - Remark 
Verdict 
 
 
b) Test hook of fig. 4 for 10 s (20 N) 
Test with test hook results 
in no hazard. 
 
c) 30 mm diameter test tool for 5 s (100 or 250 N)  : 
Tested with 100N results in  
no damage. 
9.2 
No hazard after removing a cover by hand 
No cover removable by  
hand 
N/A 
 
10 INSULATION 
REQUIREMENTS 
 
10.1 
I
nsulation resistance (MΩ) at least 2 MΩ min. after 
surge test for basic and 4 MΩ min. for reinforced 
insulation  ................................................................. : 
> 100 M
Ω, after surge test P 
10.2 
Humidity treatment 48 h or 120 h  ........................... : 
120 h (40
°C).  
No impairment 
10.3 
Insulation resistance and dielectric strength between 
mains teminals 
(see appended table) 
 
Insulation Resistance and dielectric strength across 
BASIC or SUPPLEMENTARY insulation (Class 1) 
(see appended table) 
 
Insulation resistance and dielectric strength across 
REINFORCED insulation (Class II) 
(see appended table) 
 
 
- Page 15 of 40 - 
 
 
 
 
 Report 
No. 
89538 
 
TRF No:  IEC/EN 60065G 
 
IEC/EN 60065 
Clause 
Requirement – Test 
Result - Remark 
Verdict 
 
11 FAULT 
CONDITIONS 
11.1 
No shock hazard under fault condition 
No electric shock hazard.
 
11.2 
Heating under fault condition 
See attachment, Tables to  
EN/IEC 60065 7
th
 edition 
 
No hazard from softening solder 
No softening of solder 
 
Flames extinguish within 10 seconds 
No flames 
 
Soldered terminations not used  as protective 
mechanism 
No protective mechanism 
11.2.1 
Measurement of temperature rises 
See attachment, Tables to  
EN/IEC 60065 7
th
 edition 
11.2.2 
Temperature rise of accessible parts 
See attachment, Tables to  
EN/IEC 60065 7
th
 edition 
11.2.3 
Temperature rise of parts, other than windings, 
providing electrical insulation 
See attachment, Tables to  
EN/IEC 60065 7
th
 edition 
 
Temperature rise of printed circuit boards (PCB) 
exceeding the limits of table 3 by max. 100 K for max. 
5 min 
No exceeding the limits of  
Table 3. 
 
a) Temperature rise of printed circuit boards (PCB) to 
20.1.3, exceeding the limits of table 3 by not more 
than 100 K for an area not greater than 2 cm² 
No area where temperature  
exceeds 100K above limits 
N/A 
 
b) Temperature rise of printed circuit boards (PCB) to 
20.1.3 up to 300 K for an area not greater than 2 cm² 
for a maximum of 5 min 
No area where temperature  
exceeds 300K above limits 
N/A 
 
Meets all the special conditions if conductors on 
printed circuit boards are interrupted 
No conductors are 
interrupted/peeled/loosened
 
during fault conditions 
N/A 
 
Class I protective earthing maintained 
Class II equipment 
N/A 
11.2.4 
Temperature rise of parts acting as a support or 
mechanical barrier 
Temperature rises are 
 within the limits. 
11.2.5 
Temperature rise of windings 
See attachment, Tables to  
EN/IEC 60065 7
th
 edition 
11.2.6 
Temperature rise of parts not subject to the limits of 
11.2.1 to 11.2.5 
No excessive temperature  
observed/measured on  
other parts. 
See attachment, Tables to  
EN/IEC 60065 7th edition 
 
 
- Page 16 of 40 - 
 
 
 
 
 Report 
No. 
89538 
 
TRF No:  IEC/EN 60065G 
 
IEC/EN 60065 
Clause 
Requirement – Test 
Result - Remark 
Verdict 
 
12 MECHANICAL 
STRENGTH 
 
12.1.1 
Bump test where mass >7 kg 
Mass: 3,3kg 
N/A 
12.1.2 Vibration 
test 
Assessed to be satisfactory 
constructed 
12.1.3 
Impact hammer test 
No damage in the sense of 
this standard 
 
Steel ball test 
No damage in the sense of  
this standard 
12.1.4 
Drop test for portable apparatus where mass < 7 kg 
Not portable apparatus 
N/A 
12.1.5 
Thermoplastic enclosures strain relief test 
Tested, 70ºC, 7h
 
12.2 
Fixing of knobs, push buttons, keys and levers 
Normal use will not impair 
the protection against 
electric shock. 
12.3 
Remote controls with hazardous live parts 
No cable connected  
remote control devices. 
N/A 
12.4 
Drawers (pull test 50 N, 10 s) 
No drawers 
N/A 
12.5 
Antenna coaxial sockets providing isolation 
No antenna. 
N/A 
12.6 
Telescoping or rod antennas construction 
No telescoping or rod 
antennas 
N/A 
12.6.1 
Telescoping or rod antennas securement 
 N/A 
 
13 
CLEARANCE AND CREEPAGE DISTANCES 
 
13.1 
Clearances in accordance with 13.3 
See attachment, Table to 
EN/IEC 60065 7
th
 edition. 
 
Creepage distances in accordance with 13.4 
See attachment, Table to 
EN/IEC 60065 7
th
 edition. 
13.2 
Determination of operating voltage 
Conventional switching  
transformer used.  
Upper rated supply voltage  
applied in determining the  
operating voltage 
13.3 Clearances 
2N for internal parts and 
30N for enclosures are 
considered when 
determining clearances. 
 
 
- Page 17 of 40 - 
 
 
 
 
 Report 
No. 
89538 
 
TRF No:  IEC/EN 60065G 
 
IEC/EN 60065 
Clause 
Requirement – Test 
Result - Remark 
Verdict 
 
13.3.1 General 
 P 
13.3.2 
Circuits conductively connected to the mains comply 
with table 8 and, where applicable, table 9 
See attachment, Tables to  
EN/IEC 60065 7
th
 edition 
13.3.3 
Circuits not conductively connected to the mains 
comply with table 10 
No hazardous secondary 
voltages 
N/A 
13.3.4 
Measurement of transient voltages 
No measurement of 
transient voltages 
N/A 
13.4 Creepage 
distances 
CTI > 100 
See attachment, Tables to  
EN/IEC 60065 7
th
 edition 
 
Creepage distances greater than table 11 minima 
Not applicable 
N/A 
13.5 Printed 
boards 
 N/A 
13.5.1 
Clearances and creepage distances between 
conductors on printed circuit boards, one of which 
may be conductively connected to the mains, as in 
fig. 10 
No such PCB used 
N/A 
13.5.2 
Type B coated printed circuit boards complying with 
IEC 60664-3 (basic insulation only) 
No type B coated printed  
circuit boards 
N/A 
13.6 
Conductive parts along uncemented joints 
clearances and creepage distances comply with 13.3 
and 13.4 
Jointed insulation not applied 
N/A 
 
Conductive parts along reliably cemented joints 
comply with 8.8 
 N/A 
 
Temperature cycle test and dielectric strength test 
 N/A 
13.7 
Enclosed, enveloped or hermetically sealed parts: 
not conductively connected to the mains: clearances 
and creepage distances as in table 12 
No enclosed, enveloped or 
hermetically sealed parts 
N/A 
13.8 
Parts filled with insulating compound, meeting the 
requirements of 8.8 
Approved optocouplers,  
see list of critical components. 
 