Harman Kardon DVD 29 (serv.man3) EMC - CB Certificate ▷ View online
- Page 10 of 40 -
Report
No.
89538
TRF No: IEC/EN 60065G
IEC/EN 60065
Clause
Requirement – Test
Result - Remark
Verdict
8
CONSTRUCTIONAL REQUIREMENTS WITH REGARD TO THE PROTECTION
AGAINST ELECTRIC SHOCK
AGAINST ELECTRIC SHOCK
8.1
Conductive parts covered by lacquer, paper,
untreated textile oxide films and beads etc.
considered to be bare
untreated textile oxide films and beads etc.
considered to be bare
Considered
P
8.2
No shock hazard when changing voltage setting
device, fuse-links or handling drawers etc.
device, fuse-links or handling drawers etc.
Operation “By hand”
not possible
not possible
N/A
8.3
Insulation of hazardous live parts not provided by
hygroscopic material
hygroscopic material
No hygroscopic materials
N/A
8.4
No risk of electric shock following the removal of a
cover which can be removed by hand
cover which can be removed by hand
No cover removable by
hand
hand
N/A
8.5
Class I equipment
Class II equipment
N/A
Basic insulation between hazardous live parts and
earthed accessible parts
earthed accessible parts
N/A
Resistors bridging basic insulation complying with
14.1 a)
14.1 a)
N/A
8.6
Class II equipment and Class II constructions within
Class I equipment
Class I equipment
Class II apparatus.
P
Reinforced or double insulation between hazardous
live parts and accessible parts
live parts and accessible parts
Double/Reinforced
insulation complies with
requirements specified in
clause 10 and 13.
insulation complies with
requirements specified in
clause 10 and 13.
P
Components bridging reinforced or double insulation
complying with 14.1 a) or 14.3
complying with 14.1 a) or 14.3
The apparatus has isolating
transformer.
transformer.
P
Basic and supplementary insulation each being
bridged by a capacitor complying with 14.1 a)
bridged by a capacitor complying with 14.1 a)
No such capacitors.
N/A
Reinforced or double insulation being bridged with 2
capacitors in series complying with 14.2.1 a)
capacitors in series complying with 14.2.1 a)
No such capacitors.
N/A
Reinforced or double insulation being bridged with a
single capacitor complying with 14.2.1 b)
single capacitor complying with 14.2.1 b)
C930, C932, and C933
capacitors; inside the
enclosure
capacitors; inside the
enclosure
P
Basic insulation bridged by components complying
with 14.3.4.3
with 14.3.4.3
No such components.
N/A
- Page 11 of 40 -
Report
No.
89538
TRF No: IEC/EN 60065G
IEC/EN 60065
Clause
Requirement – Test
Result - Remark
Verdict
8.7
This clause is void
—
8.8
Basic or supplementary insulation > 0,4 mm (mm) :
N/A
Reinforced insulation > 0,4 mm (mm) .................... :
a. Transformer bobbin
thick.: >0,4mm, ref. 14.3.
b. Sheet of insulation in
bottom side of the SMPS
between primary and
metal
thick.: >0,4mm, ref. 14.3.
b. Sheet of insulation in
bottom side of the SMPS
between primary and
metal
chassis.
Tested at 3KV, 1 min. acc.
to clause 10.3 - OK
c. Distance through insulation
in
to clause 10.3 - OK
c. Distance through insulation
in
optocoupler
≥0.4 mm.
ref.
14.11.
P
Thin sheet insulation (excluding non-separable thin
sheet insulation. See 8.22)
sheet insulation. See 8.22)
P
Basic or supplementary insulation, at least two
layers, each meeting 10.3
layers, each meeting 10.3
N/A
Basic or supplementary insulation, three layers any
two of which meet 10.3
two of which meet 10.3
N/A
Reinforced insulation, two layers each of which meet
10.3
10.3
N/A
Reinforced insulation, three layers any two which
meet 10.3
meet 10.3
Insulation in T901 transf.
between pri. and sec.
windings.
between pri. and sec.
windings.
P
8.9
Adequate insulation between internal hazardous live
conductors and accessible parts
conductors and accessible parts
External supply cord only,
double insulated.
double insulated.
P
Adequate insulation between internal hazardous live
parts and conductors connected to accessible parts
parts and conductors connected to accessible parts
Single insulation but
safely anchored
safely anchored
P
8.10
Double insulation between conductors connected to
the mains and accessible parts.
the mains and accessible parts.
Double insulation between internal hazardous live
parts and conductors connected to accessible parts.
parts and conductors connected to accessible parts.
Double insulated, tested
according to 8.9. and 10.3.
according to 8.9. and 10.3.
P
- Page 12 of 40 -
Report
No.
89538
TRF No: IEC/EN 60065G
IEC/EN 60065
Clause
Requirement – Test
Result - Remark
Verdict
8.11
Detaching of wires
P
No undue reduction of creepages or clearance
distances if wires become detached
distances if wires become detached
Primary wires in external
cords connected with
multi-contact-housing.
cords connected with
multi-contact-housing.
P
Vibration
test
carried out ........................................ :
See 12.1.2
N/A
8.12
This clause is void
—
8.13
Adequate fastening of windows, lenses, lamp covers
etc. (pull test 20 N for 10 s)
etc. (pull test 20 N for 10 s)
Adequately fastened.
P
8.14
Adequate fastening of covers (pull test 50 N for 10 s)
Covers adequately
fastened with screws.
fastened with screws.
P
8.15
No risk of damage to the insulation of internal wiring
due to hot parts or sharp edges
due to hot parts or sharp edges
Wires safely anchored
away from parts with high
temperature.
away from parts with high
temperature.
P
8.16
Only special supply equipment can be used
Not supplied by a special
supply apparatus.
supply apparatus.
N/A
8.17
Insulated winding wire without additional interleaved
insulation
insulation
No such winding wire.
N/A
8.18
Endurance test as required by 8.17
N/A
8.19
Disconnection from the mains
See below
P
8.19.1 Disconnect
device
Mains plug is used as
disconnect device
disconnect device
P
All-pole switch or circuit breaker with >3mm contact
separation
separation
No mains switch
N/A
8.19.2
Mains switch ON indication
No mains switch
N/A
8.20
Switch not fitted in the mains cord
P
8.21
Bridging components comply with clause 14
No bridging components for
switch
switch
N/A
8.22
Non-separable thin sheet material
No Non-separable thin
sheet material
sheet material
N/A
- Page 13 of 40 -
Report
No.
89538
TRF No: IEC/EN 60065G
IEC/EN 60065
Clause
Requirement – Test
Result - Remark
Verdict
9
ELECTRIC SHOCK HAZARD UNDER NORMAL OPERATING CONDITIONS
9.1
Testing on the outside
P
9.1.1
For voltages >1000 V ac or >1500 V dc complies
with clause 13.3.1 for basic insulation
with clause 13.3.1 for basic insulation
No voltages exceeding
1000V AC or 1500V DC.
1000V AC or 1500V DC.
N/A
9.1.1.1
a) Open circuit voltages
Mains input voltage > 35V,
see below.
see below.
—
b) Touch current measured from terminal devices
using the network in annex D ................................. :
using the network in annex D ................................. :
See attachment, Table to
EN/IEC 60065 7
EN/IEC 60065 7
th
Edition
P
c) Discharge not exceeding 45 μC
No part or contact of a
terminal with stored voltages
between 60V - 15 kV.
terminal with stored voltages
between 60V - 15 kV.
N/A
d) Energy of discharge not exceeding 350 mJ
No part or contact of
a terminal with stored
voltages exceeding 15kV
a terminal with stored
voltages exceeding 15kV
N/A
9.1.1.2
Test with test finger and test probe
No access to hazardous
live parts
live parts
P
9.1.2
No hazardous live shafts of knobs, handles or levers
No live shaft, handles or
levers
levers
N/A
9.1.3
Ventilation holes and other holes tested by means of
4 mm x 100 mm test pin
4 mm x 100 mm test pin
No ventilation holes in top
side of the cover.
side of the cover.
N/A
9.1.4
Terminal devices tested with 1 mm x 20 mm test pin
(10 N); test probe D of IEC 61032
(10 N); test probe D of IEC 61032
Does not reach hazardous
live parts
live parts
P
Terminal devices tested with 1 mm x 100 mm straight
wire (1 N); test probe D of IEC 61032
wire (1 N); test probe D of IEC 61032
Does not reach hazardous
live parts
live parts
P
9.1.5
Pre-set controls tested with 2.5 mm x 100 mm test
pin (10 N); test probe C of IEC 61032
pin (10 N); test probe C of IEC 61032
No preset controls
N/A
9.1.6
No shock hazard due to stored charge on withdrawal
of the mains plug; voltage (V) after 2 s .................. :
of the mains plug; voltage (V) after 2 s .................. :
Measured discharge voltage
after 2 sec.: <1V (peak)
Discharge resistor provided,
R901 (1M
after 2 sec.: <1V (peak)
Discharge resistor provided,
R901 (1M
Ω, 1/2W)
P
If C is not greater than 0,1 μF no test needed
N/A
9.1.7
a) Enclosure sufficiently resistant to external force
P
Test probe 11 of IEC 61032 for 10 s (50 N)
Test with test finger
result in no hazard
result in no hazard
P