DOWNLOAD Harman Kardon DVD 22 Service Manual ↓ Size: 4.61 MB | Pages: 109 in PDF or view online for FREE

Model
DVD 22
Pages
109
Size
4.61 MB
Type
PDF
Document
EMC - CB Certificate
Brand
Device
Audio
File
dvd-22.pdf
Date

Harman Kardon DVD 22 EMC - CB Certificate ▷ View online

 
 
page 19 of 35 
Ref.No.: 312941   
IEC 60065 
Clause 
Requirement - Test 
Result - Remark 
Verdict 
 
 
 
 
20 
RESISTANCE TO FIRE 
 
20.1 
Electrical components and mechanical parts 
 
 
a) Exemption for components contained in an 
enclosure of material FV 0 to IEC 60707 with 
openings not exceeding 1 mm in width 
 N 
 
b) Exemption for small components as defined in 
20.1 
 P 
20.1.1 Electrical 
components meet the requirements of 
14.2.5, 14.4, 14.5.3, 14.6.6 or 20.1.4 
(See list of critical components) 
20.1.2 
Insulation of internal wiring working at voltages 
> 4 kV or leaving an internal fire enclosure, not 
contributing to the spread of fire 
 N 
20.1.3 
Material of printed circuit boards on which the 
available power exceeds 15 W at a voltage 
between 50 V and 400 V (peak) a.c. or d.c. meets 
FV 1 or better to IEC 60707, unless used in a fire 
enclosure 
(See list of critical components) 
 
Material of printed circuit boards on which the 
available power exceeds 15 W at a voltage 
exceeding 400 V (peak) a.c. or d.c. meets FV 0 to 
IEC 60707 
 N 
20.1.4 
Components and parts not covered by 20.1.1, 
20.1.2 and 20.1.3 (other than fire enclosures) 
mounted nearer to a potential ignition source than 
the distances in Table 13 comply with the relevant 
flammability category in Table 13 
(See list of critical components) 
 
Components and parts as above but shielded from 
a potential ignition source, with the barrier area in 
accordance with Table 13 and fig. 13 
 N 
20.2 
Fire enclosure 
20.2.1 
Potential ignition sources with open circuit voltage 
> 4 kV (peak) a.c. or d.c. contained in a fire 
enclosure to FV 1 
 N 
20.2.2 Internal 
fire enclosures with openings not 
exceeding 1 mm in width and with openings for 
wires completely filled 
 N 
20.2.3 
Requirements of 20.2.1 and 20.2.2 met by an 
internal fire enclosure 
 N 
 
 
 
page 20 of 35 
Ref.No.: 312941   
IEC 60065 
Clause 
Requirement - Test 
Result - Remark 
Verdict 
 
 
 
 
APPENDIX A, ADDITIONAL REQUIREMENTS FOR APPARATUS WITH 
PROTECTION AGAINST SPLASHING WATER 
 
A.5.1 
j) Marked with IPX4 (IEC 60529), 5.4.1 a) does not 
apply 
 N 
A.10.2.1 
Enclosure provides protection against splashing 
water 
 N 
A.10.2.2 
Humidity treatment carried out for 7 days 
 
 
APPENDIX B, APPARATUS TO BE CONNECTED TO THE 
TELECOMMUNICATION NETWORKS 
 
B.5.4.1 
e) Where the separation of TNV circuits from other 
circuits relies on protective earthing the 
instructions make it clear that protective earthing is 
essential 
 N 
B.8.1 
TNV circuits separated from the mains circuit and from hazardous live parts by 
either: 
 
 
a) double or reinforced insulation 
 
 
b) basic insulation with earthed protective 
screening 
 N 
B.8.2 
TNV circuits separated from circuits other than 
those in B.8.1 and from accessible conductive 
parts by basic insulation meeting the requirements 
for clearances and creepage distances for the 
voltages concerned 
 N 
B.9.1.1 
TNV circuit terminals contacts which cannot be 
touched by probe B.1, exempt from the 
requirements inaccessible terminal contacts in 
9.1.1 
 N 
B.10.1 
Insulation between TNV terminals and antenna 
terminals (including interconnection terminals 
which may be connected to equipment with 
antenna terminals) withstands the 50 discharges of 
10.1 
 N 
B.14.12 
Surge suppressors between TNV circuits and 
other parts of the equipment have breakdown 
voltage at least 1.8 times the mains voltage 
 N 
 
 
 
page 21 of 35 
Ref.No.: 312941   
IEC 60065 
Clause 
Requirement - Test 
Result - Remark 
Verdict 
 
 
 
 
7.1 
TABLE: temperature rise measurements 
 
Power consumption in the OFF/Stand-by 
position of the functional switch (W)  ...................... :
0 W / 1W 
 
 
Operating conditions 
DVD play mode. 
Un (V) 
In (A) 
Pn (W) 
Pout (W) 
265 0.114 14.1  -- 
90 0.245 13.3  -- 
 
 
Loudspeaker impedance (
Ω) ................................. : -- 
 
 Several 
loudspeaker 
systems 
-- 
-- 
 
Marking of loudspeaker terminals 
-- 
-- 
monitored point: 
dT (K) 
90/265 
Permitted dT (K) 
Winding of transformer - TR1 
21/25 
75* 
Winding of line filter - LF1 
16/10 
75* 
Iron core TR1 
19/24 
— 
Supply wiring insulation (Not under mechanical stress.) 
8/7 
60 
PCB (near D10) 
27/27 
85 
Buttons (plastic) 
2/1 
50 
Enclosure (metal) 
6/5 
40 
 
Winding temperature rise measurements 
 
 
Ambient temperature t1 (ºC)  .................................. :  
 
 
Ambient temperature t2 (
°C) .................................. :  
 
temperature rise dT of winding: 
R
1
 (
Ω) 
R
2
 (
Ω) 
dT (K) 
permitted 
dT (K) 
insulation 
class 
 
 
 
 
 
 
 
 
 
 
 
 
 
* The limit value reduced by 10K due to the  thermal coupler method used.
 
 
page 22 of 35 
Ref.No.: 312941   
IEC 60065 
Clause 
Requirement - Test 
Result - Remark 
Verdict 
 
 
 
 
7.2 
TABLE: softening temperature of thermoplastics 
temperature T of part 
T - normal  
conditions (ºC) 
T - fault  
conditions (ºC) 
T softening 
(ºC) 
 
 
 
 
 
 
 
 
10.3 
TABLE: insulation resistance measurements 
insulation resistance R between: 
R (M
Ω) 
required R (M
Ω) 
Between the poles of the circuit directly connected to the 
supply mains. 
>100 2 
Reinforced insulation. 
>100 
 
10.3 
TABLE: electric strength measurements 
test voltage applied between: 
test voltage (V) 
Breakdown 
Between the poles of the circuit directly connected to the 
supply mains. 
2120V peak 
No 
Reinforced insulation. 
4240V peak 
No 
 
 
Page of 109