14.3.4.1
Class
ΙΙ transformers have adequate separation
between hazardous live windings and accessible
windings (double or reinforced insulation)
windings (double or reinforced insulation)
TR1
Prim. – Sec.= 6.1 mm
Prim. – Sec.= 6.1 mm
Reinforced
P
Coil formers and partition walls
≥ 0.4 mm
1mm P
14.3.4.2
Class
Ι transformers, with basic insulation and
protective screening only if all 7 conditions of
14.3.4.2 are met
14.3.4.2 are met
N
14.3.4.3
Separating transformers with at least basic
insulation
insulation
N
14.3.5.1
Class
ΙΙ transformers have adequate insulation
between hazardous live windings and accessible
parts (double or reinforced insulation)
parts (double or reinforced insulation)
Iron core in TR1 not connected
to acc. parts.
to acc. parts.
P
Coil formers and partition walls
≥ 0.4 mm
P
14.3.5.2
Class
Ι transformers have adequate insulation
between hazardous live parts and accessible
conductive parts or those conductive parts or
protective screens connected to a protective earth
terminal
conductive parts or those conductive parts or
protective screens connected to a protective earth
terminal
N
Winding wires connected to protective earth have
adequate current-carrying capacity
adequate current-carrying capacity
N
14.4
High voltage components
High-voltage components and assemblies:
U > 4 kV (peak) separately approved
U > 4 kV (peak) separately approved
No high-voltage component
N
Component meets category FV 1 of IEC 60707
N
14.4.1
High voltage transformers and multipliers tested as
part of the submission
part of the submission
N
14.5
Protective devices
Protective devices used within their ratings
P
External clearance and creepage distances
appropriate for the voltage across the device when
opened
appropriate for the voltage across the device when
opened
P
page 12 of 35
Ref.No.: 312941
IEC 60065
Clause
Requirement - Test
Result - Remark
Verdict
14.5.1.1
a) Thermal cut-outs separately approved
N
b) Thermal cut-outs tested as part of the
submission
submission
N
14.5.1.2
a) Thermal links separately approved
N
b) Thermal links tested as part of the submission
N
14.5.1.3
Thermal devices resettable by soldering
N
14.5.2.1
Fuse-links in the mains circuit according to
IEC 60127
IEC 60127
FU1 approved
P
14.5.2.2 Correct
marking of fuse-links adjacent to holder ... : T1AL250V
P
14.5.2.3
Not possible to connect fuses in parallel ............... : No
P
14.5.2.4
Not possible to touch hazardous live parts when
replacing fuse-links without the use of a tool ......... :
replacing fuse-links without the use of a tool ......... :
Tools are required.
P
14.5.3
PTC-S thermistors comply with IEC 60738
N
PTC-S devices (15 W) category FV 1 or better
N
14.5.4
Circuit protectors have adequate breaking capacity
and their position is correctly marked
and their position is correctly marked
N
page 13 of 35
Ref.No.: 312941
IEC 60065
Clause
Requirement - Test
Result - Remark
Verdict
14.6
Switches
(See appended table)
14.6.1
Permanently connected equipment provided with
an all-pole mains switch unless 5.4.2 is met
an all-pole mains switch unless 5.4.2 is met
N
14.6.2
Manually operated mechanical switch (MOMS),
required where power consumption > 15 W and/or
peak voltage > 4 kV; MOMS required .................... :
required where power consumption > 15 W and/or
peak voltage > 4 kV; MOMS required .................... :
No, measured 14.1W under
normal condition.
normal condition.
N
Switch readily accessible and not in mains cord
N
Exception for automatic switching
N
Exception for continuous operation
N
14.6.3
Manually operated mechanical switch (MOMS):
switch indication On position clearly discernible
switch indication On position clearly discernible
. N
Indication by marking meets Cl. 5
N
Indication of the OFF position
N
14.6.4
Manually operated mechanical switch (MOMS)
fitted, is there a Stand-by mode ............................. :
fitted, is there a Stand-by mode ............................. :
N
Stand-by mode clearly discernible ......................... :
N
Exception for low Stand-by current < 0.7 mA
(peak)
(peak)
N
14.6.5
Components bridging contacts of mains switches
comply with 14.1 a) or 14.2.2
comply with 14.1 a) or 14.2.2
N
14.6.6
Manually operated mechanical switches (MOMS)
separately approved to IEC 61058-1
separately approved to IEC 61058-1
N
Manually operated mechanical switch (MOMS)
tested as part of the equipment complies with
14.6.7, 14.6.10 and 20.1.4 and meets 14.6.8
and/or 14.6.9 and Annex G (G1.1)
tested as part of the equipment complies with
14.6.7, 14.6.10 and 20.1.4 and meets 14.6.8
and/or 14.6.9 and Annex G (G1.1)
N
14.7
Safety interlocks
Safety interlocks to 2.8 of IEC 60950
N
14.8
Voltage setting devices
Voltage setting device not likely to be changed
accidentally
accidentally
N
page 14 of 35
Ref.No.: 312941
IEC 60065
Clause
Requirement - Test
Result - Remark
Verdict
14.9
Motors (Low voltage DC-motor)
14.9.1
Endurance test on motors
N
Motor
start
test
N
Dielectric
strength
test
N
14.9.2
Not adversely affected by oil or grease etc.
N
14.9.3
Protection against moving parts
N
14.9.4
Motors with phase-shifting capacitors, three-phase
motors and series motors meet Cl. B.8, B.9 and
B.10 of IEC 60950, Annex B
motors and series motors meet Cl. B.8, B.9 and
B.10 of IEC 60950, Annex B
N
14.10
Batteries
14.10.1
Batteries mounted with no risk of accumulation of
flammable gases
flammable gases
N
14.10.2 No
possibility of recharging non-rechargeable
batteries
N
14.10.3
Recharging currents and times within
manufacturers limits
manufacturers limits
N
Lithium batteries discharge and reverse currents
within the manufacturers limits
within the manufacturers limits
N
14.11
Optocouplers
Optocouplers comply with Cl. 8
P
Internal and external dimensions to 13.1.1
External: 8mm
Internal: 6.5mm
Distance through insulation:
4.5mm
4.5mm
P
15 TERMINALS
15.1.1
Mains plug, appliance inlet, interconnection
couplers and mains socket-outlet meet the
appropriate standard
couplers and mains socket-outlet meet the
appropriate standard
(See critical components.)
P
15.1.2
Connectors for antenna, earth, audio, video or data:
No risk of insertion in mains socket-outlets
P
No risk of insertion into audio or video: outlets
marked with the symbol of 5.2
marked with the symbol of 5.2
N
15.1.3
Output terminals of AC adaptors or similar devices
not compatible with household mains socket-
outlets
not compatible with household mains socket-
outlets
N