page 11 of 35 
Ref.No.: 312941   
IEC 60065 
Clause 
Requirement - Test 
Result - Remark 
Verdict 
 
 
 
 
14.3.4.1 
Class 
ΙΙ transformers have adequate separation 
between hazardous live windings and accessible 
windings (double or reinforced insulation) 
TR1  
Prim. – Sec.= 6.1 mm  
Reinforced 
 
Coil formers and partition walls 
≥ 0.4 mm 
1mm P 
14.3.4.2 
Class 
Ι transformers, with basic insulation and 
protective screening only if all 7 conditions of 
14.3.4.2 are met 
 N 
14.3.4.3 
Separating transformers with at least basic 
insulation 
 N 
14.3.5.1 
Class 
ΙΙ transformers have adequate insulation 
between hazardous live windings and accessible 
parts (double or reinforced insulation) 
Iron core in TR1 not connected 
to acc. parts. 
 
Coil formers and partition walls 
≥ 0.4 mm 
 P 
14.3.5.2 
Class 
Ι transformers have adequate insulation 
between hazardous live parts and accessible 
conductive parts or those conductive parts or 
protective screens connected to a protective earth 
terminal 
 N 
 
Winding wires connected to protective earth have 
adequate current-carrying capacity 
 N 
14.4 
High voltage components 
 
High-voltage components and assemblies: 
U > 4 kV (peak) separately approved 
No high-voltage component 
 
Component meets category FV 1 of IEC 60707 
 
14.4.1 
High voltage transformers and multipliers tested as 
part of the submission 
 N 
14.5 
Protective devices 
 
Protective devices used within their ratings 
 
 
External clearance and creepage distances 
appropriate for the voltage across the device when 
opened 
 P 
 
 
page 12 of 35 
Ref.No.: 312941   
IEC 60065 
Clause 
Requirement - Test 
Result - Remark 
Verdict 
 
 
 
 
14.5.1.1 
a) Thermal cut-outs separately approved 
 
 
b) Thermal cut-outs tested as part of the 
submission 
 N 
14.5.1.2 
a) Thermal links separately approved 
 
 
b) Thermal links tested as part of the submission 
 
14.5.1.3 
Thermal devices resettable by soldering 
 
14.5.2.1 
Fuse-links in the mains circuit according to 
IEC 60127 
FU1 approved 
14.5.2.2 Correct 
marking of fuse-links adjacent to holder  ... : T1AL250V 
 
14.5.2.3 
Not possible to connect fuses in parallel  ............... : No 
14.5.2.4 
Not possible to touch hazardous live parts when 
replacing fuse-links without the use of a tool ......... :
 
Tools are required. 
14.5.3 
PTC-S thermistors comply with IEC 60738 
 
 
PTC-S devices (15 W) category FV 1 or better 
 
14.5.4 
Circuit protectors have adequate breaking capacity 
and their position is correctly marked 
 N 
 
 
 
page 13 of 35 
Ref.No.: 312941   
IEC 60065 
Clause 
Requirement - Test 
Result - Remark 
Verdict 
 
 
 
 
14.6 
Switches 
 
 
 
 
 
(See appended table) 
14.6.1 
Permanently connected equipment provided with 
an all-pole mains switch unless 5.4.2 is met 
 N 
14.6.2 
Manually operated mechanical switch (MOMS), 
required where power consumption > 15 W and/or 
peak voltage > 4 kV; MOMS required .................... :
No, measured 14.1W under 
normal condition. 
 
Switch readily accessible and not in mains cord 
 
 
Exception for automatic switching 
 
 
Exception for continuous operation 
 
14.6.3 
Manually operated mechanical switch (MOMS): 
switch indication On position clearly discernible 
. N 
 
Indication by marking meets Cl. 5 
 
 
Indication of the OFF position 
 
14.6.4 
Manually operated mechanical switch (MOMS) 
fitted, is there a Stand-by mode  ............................. :
 N 
 
Stand-by mode clearly discernible ......................... :  
 
Exception for low Stand-by current < 0.7 mA 
(peak) 
 N 
14.6.5 
Components bridging contacts of mains switches 
comply with 14.1 a) or 14.2.2 
 N 
14.6.6 
Manually operated mechanical switches (MOMS) 
separately approved to IEC 61058-1 
 N 
 
Manually operated mechanical switch (MOMS) 
tested as part of the equipment complies with 
14.6.7, 14.6.10 and 20.1.4 and meets 14.6.8 
and/or 14.6.9 and Annex G (G1.1) 
 N 
14.7 
Safety interlocks 
 
Safety interlocks to 2.8 of IEC 60950 
 
14.8 
Voltage setting devices 
 
Voltage setting device not likely to be changed 
accidentally 
 N 
 
 
page 14 of 35 
Ref.No.: 312941   
IEC 60065 
Clause 
Requirement - Test 
Result - Remark 
Verdict 
 
 
 
 
14.9 
Motors                                                                         (Low voltage DC-motor) 
14.9.1 
Endurance test on motors 
 
 Motor 
start 
test 
 
 Dielectric 
strength 
test 
 
14.9.2 
Not adversely affected by oil or grease etc. 
 
14.9.3 
Protection against moving parts 
 
14.9.4 
Motors with phase-shifting capacitors, three-phase 
motors and series motors meet Cl. B.8, B.9 and 
B.10 of IEC 60950, Annex B 
 N 
14.10 
Batteries 
14.10.1 
Batteries mounted with no risk of accumulation of 
flammable gases 
 N 
14.10.2 No 
possibility of recharging non-rechargeable 
batteries 
 N 
14.10.3 
Recharging currents and times within 
manufacturers limits 
 N 
 
Lithium batteries discharge and reverse currents 
within the manufacturers limits 
 N 
14.11 
Optocouplers 
 
Optocouplers comply with Cl. 8 
 
 
Internal and external dimensions to 13.1.1 
External: 8mm 
Internal: 6.5mm 
Distance through insulation: 
4.5mm 
 
15 TERMINALS 
 
15.1.1 
Mains plug, appliance inlet, interconnection 
couplers and mains socket-outlet meet the 
appropriate standard 
(See critical components.) 
15.1.2 
Connectors for antenna, earth, audio, video or data: 
 
No risk of insertion in mains socket-outlets 
 
 
No risk of insertion into audio or video: outlets 
marked with the symbol of 5.2 
 N 
15.1.3 
Output terminals of AC adaptors or similar devices 
not compatible with household mains socket-
outlets 
 N 
Page of 109