Harman Kardon DVD 22 (serv.man2) EMC - CB Certificate ▷ View online
Test report no. JSH0311046-001
Page 17 of 21
9. Measurement of screening effectiveness
9.1 Test result
Pass Fail Not Applicable
9.2 Operating environment
Temperature: 22
°C
Relative Humidity: 55%
9.3 Test set up
9.3 Test set up
The measuring set up is shown in the following figure.
Test report no. JSH0311046-001
Page 18 of 21
9.4 Test protocol
PASS
Test report no. JSH0311046-001
Page 19 of 21
10. Measurement of electrical transient
10.1 Test result
Pass Fail Not Applicable
10.2 Operating environment
Temperature: 22°C
Relative Humidity: 51%
10.3 Test set-up
The EUT was placed on a non-metallic table 0,8m above a reference ground plane (RGP) and was put
into operation according to the specified operating mode.
10.4 Test conditions
Test level: 1kV AC mains
Performance criterion: B
Repetition rate; 5kHz
Application method: AC mains
Duration of each test: 2 min
Lines for test: AC mains
EUT-position: Table top
/floor standing
10.5 Measurement uncertainty
The uncertainty of the applied fast transient/burst is within the tolerance specified by the standard.
10.6 Test protocol
Test No.
#
Level
[kV]
Polarity
+/-
Line for test
Pass/
Fail
Comment
1 1 +
AC
mains P
2 1 -
AC
mains P
Test report no. JSH0311046-001
Page 20 of 21
11. Measurement of electrostatic discharge
11.1 Test result
Pass Fail Not Applicable
11.2 Operating environment
Temperature: 22
°C
Relative Humidity: 55%
11.3 Test set-up
<Floor standing>The EUT was placed on a non-metallic support 0,1m above a reference ground plane
(RGP) and was put into operation according to the specified operating mode.
<Table top>A horizontal coupling plane (HCP) was placed on a 0.8m high non-metallic table above a
2.6m by 1.8m reference ground plane (RGP) and connected to it through a cable with two 470k
11.3 Test set-up
<Floor standing>The EUT was placed on a non-metallic support 0,1m above a reference ground plane
(RGP) and was put into operation according to the specified operating mode.
<Table top>A horizontal coupling plane (HCP) was placed on a 0.8m high non-metallic table above a
2.6m by 1.8m reference ground plane (RGP) and connected to it through a cable with two 470k
Ω
resistors at each end. The EUT was placed on an insulation sheet on the HCP and was put into operation
according to the specified operating mode.
A vertical coupling plane (VCP) was connected to the RGP through a cable with two 470k
according to the specified operating mode.
A vertical coupling plane (VCP) was connected to the RGP through a cable with two 470k
Ω resistors at
each end.
11.4 Test conditions
Test level: 4kV Contact discharge
8kV Air discharge
Number of discharges
at each point: 10 of each polarity
Performance criterion: B
ETU position: Table top standing
Indirect contact discharges were applied to the VCP and the HCP The selected test points of the EUT are
listed in this table..
11.4 Test conditions
Test level: 4kV Contact discharge
8kV Air discharge
Number of discharges
at each point: 10 of each polarity
Performance criterion: B
ETU position: Table top standing
Indirect contact discharges were applied to the VCP and the HCP The selected test points of the EUT are
listed in this table..
Point Description
Point Description
HCP f 0,1m from the front of the EUT
Edge of centre,coner on HCP
HCP b 0,1m from the back of the EUT
Edge of centre,coner on HCP
HCP r 0,1m from the right side of the EUT
Edge of centre,coner on HCP
HCP l
0,1m from the left side of the EUT
Edge of centre,coner on HCP
VCP f 0,1m from the front of the EUT
Edge of centre,coner on VCP
VCP b 0,1m from the back of the EUT
Edge of centre,coner on VCP
VCP r 0,1m from the right of the EUT
Edge of centre,coner on VCP
VCP l
0,1m from the left of the EUT
Edge of centre,coner on VCP
.