DOWNLOAD Harman Kardon DVD 22 (serv.man2) Service Manual ↓ Size: 2.1 MB | Pages: 41 in PDF or view online for FREE

Model
DVD 22 (serv.man2)
Pages
41
Size
2.1 MB
Type
PDF
Document
EMC - CB Certificate
Brand
Device
Audio
File
dvd-22-sm2.pdf
Date

Harman Kardon DVD 22 (serv.man2) EMC - CB Certificate ▷ View online

 
Test report no. JSH0311046-001 
Page 9 of 21
 
Recorded data for test of input immunity from unwanted signals inside the VHF band II range 
 
                  Limit  
n
f
[dB(uV)](75
ς) 1KHz 
FN dev, 40KHz 
Fn(MHz) Ff(MHz) 
mono stereo 
Result 
97.5 and 98.5 
85 
85 
 
97.6 and 98.4 
85 
85 
 
97.65 and 98.35 
80 
80 
 
97.7 and 98.3 
72 
72 
 
97.75 and 98.25 
63 
63 
 
97.8 and 98.2 
59 
58 
 
97.85 and 98.15 
57 
47 
 
97.9 and 98.1 
53 
32 
 
97.925 and 98.075 
49 
20 
 
97.95 and 98.05 
41 
14 
 
97.975 and 98.025 
34 
14 
 
 
 
 
98 
98 29 
20 
 
 
Test report no. JSH0311046-001 
Page 10 of 21
 
5.2 Requirements for immunity to RF voltages ( in common mode) 
 
5.2.1 Test result 
 
           Pass               Fail              Not Applicable 
 
5.2.2 Operating environment 
 
Temperature:                           22
°C  
Relative Humidity:                  55%  
 
5.2.3 Test set-up 
 
 
 
The requirements for receivers,(including car radios and AM receivers), multifunction 
equipment and video tape equipment concerning the immunity to RF voltages in common model are 
restricted to the antenna terminals and to the frequency range form 26MHz to 30MHz. 
 
 
5.2.4 Test protocol 
 
NA 
 
      Frequency (MHz) 
Level ([dB(uV)]) 
e.m.f. 
    Result 
             26-30 
126 
 
 
Test report no. JSH0311046-001 
Page 11 of 21
 
6. Immunity requirements at loudspeaker and headphone output connector 
 
6.1 Test result 
 
           Pass               Fail              Not Applicable 
 
6.2 Operating environment 
 
Temperature:                           22
°C  
Relative Humidity:                  55%  
 
6.3 Test set-up 
 
The wanted test signal is supplied by generators G1,G2,G3 and G4, via the respective connections A or 
V or S or T and the unwanted signal is supplied by generator G5. Network RCi matches the RF 
disturbance source to the input impedance of the relevant audio terminal and a similar network Rco is 
used to match the output terminals. Mains stop filter MSF is used to inject the unwanted signal at the 
mains terminal and acts as a stop filter for unwanted signals from the mains network. 
 The equipment under test is placed 0.1m above the centre of a metal ground plane of dimensions 2m by 
1m. The mains lead shall be bundled to a length less than 0.3m and connected in the shortest possible 
way to the mains stop filter MSF. The connection between the metal ground plane and the shield of the 
RF cable at the audio input and output terminals shall be as short as possible.  
The connecting cables are of the 50
Ω coaxial type. 
The unwanted signal was amplitude modulated with 1kHz at 80% depth, supplied by generator G5. 
 
6.4 Performance Criterion : A 
 
 
 
Test report no. JSH0311046-001 
Page 12 of 21
 
 
6.5 Figure for test set up 
 
 
Page of 41
Display