Harman Kardon BDS 280 (serv.man4) EMC - CB Certificate ▷ View online
R
AUDIX Technology (Shenzhen) Co., Ltd.
Audix Technology (Shenzhen) Co., Ltd. Report No. ACS-E13288 page 49 of 401
5.2.3. In 3m Anechoic Chamber Test Setup Diagram for 1-6GHz
5.3. Test Standard
EN55022: 2010+AC:2011 (Class B) and EN 55013: 2001+A1: 2003+A2:2006
5.4. Radiated Emission Limit
All emanations from a devices or system, including any network of conductors and
apparatus connected thereto, shall not exceed the level of field strengths specified below:
Test Standard: EN55013: 2001+A1: 2003+A2:2006
Test Standard: EN55013: 2001+A1: 2003+A2:2006
DISTANCE
Source
(Meters)
FREQUENCY
(MHz)
Limits(dB
μV/m)
Quasi-Peak
3
≦
1000
Fundamental 60
3
30~300
Harmonics 52
Local Oscillator
3
300~1000
Harmonics 56
3 30~230
40
Other
3 230~1000
47
Note:
(1) Emission level = Antenna Factor + Cable Loss + Reading
(2) The lower limit shall apply at the transition frequencies.
(3) Distance refers to the distance in meters between the test instrument
antenna and the closed point of any part of the E.U.T.
AMP
Spectrum Analyzer
ANTENNA ELEVATION VARIES FROM 1 TO 4 METERS
3m
TURN TABLE
(FIBRE GLASS)
2.0m(L)*1.0m(W)*0.8m(H)
Semi-anechoic 3m Chamber
EUT
ABSORBER
Combining Network
PC System
Receiver
(2.4m*2.4m)
R
AUDIX Technology (Shenzhen) Co., Ltd.
Audix Technology (Shenzhen) Co., Ltd. Report No. ACS-E13288 page 50 of 401
Test Standard: EN55022: 2010+A1:2011
FREQUENCY
(MHz)
DISTANCE
(Meters)
FIELD STRENGTHS LIMITS
(dB
μV/m)
30 ~ 230
10
30
230 ~ 1000
10
37
1000~3000 3 70(Peak)
50(Average)
3000~6000 3 74(Peak)
54(Average)
Note:
(1) Emission level = Antenna Factor + Cable Loss + Reading
Emission level = Antenna Factor -Amp Factor +Cable Loss + Reading
(above 1000MHz)
(2) The lower limit shall apply at the transition frequencies.
(3) Distance refers to the distance in meters between the test instrument
antenna and the closed point of any part of the E.U.T.
5.5. EUT Configuration on Test
The configurations of EUT are listed in Section 3.5.
5.6. Operating Condition of EUT
5.6.1. Setup the EUT and simulators as shown in Section 5.2.
5.6.2. Turn on the power of all equipments.
5.6.3. Let the EUT work in test modes (BD Live / FM 88MHz/ FM 98MHz/ FM 108MHz)
5.6.2. Turn on the power of all equipments.
5.6.3. Let the EUT work in test modes (BD Live / FM 88MHz/ FM 98MHz/ FM 108MHz)
and test it.
5.7. Test Procedure
The EUT was placed on a non-metallic table, 80 cm above the ground plane inside a
semi-anechoic chamber. An antenna was located 3m from the EUT on an adjustable mast.
A pre-scan was first performed in order to find prominent radiated emissions. For final
emissions measurements at each frequency of interest, the EUT were rotated and the
antenna height was varied between 1m and 4m in order to maximize the emission.
Measurements in both horizontal and vertical polarities were made and the data was
recorded. In order to find the maximum emission, the relative positions of equipments and
all the interface cables were changed according to EN55013 and EN 55022 Class B on
Radiated Disturbance test.
semi-anechoic chamber. An antenna was located 3m from the EUT on an adjustable mast.
A pre-scan was first performed in order to find prominent radiated emissions. For final
emissions measurements at each frequency of interest, the EUT were rotated and the
antenna height was varied between 1m and 4m in order to maximize the emission.
Measurements in both horizontal and vertical polarities were made and the data was
recorded. In order to find the maximum emission, the relative positions of equipments and
all the interface cables were changed according to EN55013 and EN 55022 Class B on
Radiated Disturbance test.
The bandwidth setting on the test receiver (R&S TEST RECEIVER ESVS10) is 120 kHz.
The resolution bandwidth of the Agilent Spectrum Analyzer E4407B was set at 1MHz. (For
above 1GHz)
The frequency range from 30MHz to 1000MHz was pre-scanned with a peak detector and
all final readings of measurement from Test Receiver are Quasi-Peak values.
The frequency range from 1GHz to 6GHz was checked and all final readings of
measurement were with Peak and Average detector, measurement distance was 3m at
semi-anechoic chamber. The portion of the test volume that was obstructed by absorber
placed on the floor (30cm maximum).
Finally, selected operating situations at Anechoic Chamber measurement, all the test results
are listed in section 5.8.
above 1GHz)
The frequency range from 30MHz to 1000MHz was pre-scanned with a peak detector and
all final readings of measurement from Test Receiver are Quasi-Peak values.
The frequency range from 1GHz to 6GHz was checked and all final readings of
measurement were with Peak and Average detector, measurement distance was 3m at
semi-anechoic chamber. The portion of the test volume that was obstructed by absorber
placed on the floor (30cm maximum).
Finally, selected operating situations at Anechoic Chamber measurement, all the test results
are listed in section 5.8.
R
AUDIX Technology (Shenzhen) Co., Ltd.
Audix Technology (Shenzhen) Co., Ltd. Report No. ACS-E13288 page 51 of 401
5.8. Radiated Emission Test Results
PASS. (All emissions not reported below are too low against the prescribed limits.)
For frequency range 30MHz~1000MHz
The EUT with the following test modes were tested and selected (mode 1~5) to read Q.P
values, all the test results listed in next pages.
EUT: BLU-RAY DISC SYSTEM Model No. : BDS580
Test Date: May.25~Jun.02, 2013 Temperature: 24℃ Humidity: 59%
values, all the test results listed in next pages.
EUT: BLU-RAY DISC SYSTEM Model No. : BDS580
Test Date: May.25~Jun.02, 2013 Temperature: 24℃ Humidity: 59%
The details of test mode as follows:
Reference Test Data No.
No. Test
Mode
Horizontal Vertical
1.
BD Live(LAN)
#2 #1
2.※
BD Live(WiFi)
#3 #4
3. FM
88MHz
#31
#32
4. FM
98MHz
#35
#36
5. FM
108MHz
#34
#33
(※Worst test mode)
For frequency range 1GHz~6GHz
The EUT with below test modes were measured within Anechoic Chamber and the test
results listed in next pages
Test Date: Jun.02, 2013 Temperature: 24℃ Humidity: 56%
The details of test mode as follows:
results listed in next pages
Test Date: Jun.02, 2013 Temperature: 24℃ Humidity: 56%
The details of test mode as follows:
Reference Test Data No.
No. Test
Mode
Horizontal Vertical
1.※
BD Live
#2 #1
2. Wi-Fi
Mode
#3 #4
(※Worst test mode)
R
AUDIX Technology (Shenzhen) Co., Ltd.
Audix Technology (Shenzhen) Co., Ltd. Report No. ACS-E13288 page 52 of 401