R
 
AUDIX Technology (Shenzhen) Co., Ltd.
 
 
                                    Audix Technology (Shenzhen) Co., Ltd. Report No. ACS-E13288      page 49 of 401 
 
 
5.2.3.   In 3m Anechoic Chamber Test Setup Diagram for 1-6GHz 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
5.3. Test Standard 
EN55022: 2010+AC:2011 (Class B) and EN 55013: 2001+A1: 2003+A2:2006 
5.4. Radiated Emission Limit 
All emanations from a devices or system, including any network of conductors and 
apparatus connected thereto, shall not exceed the level of field strengths specified below: 
Test Standard: EN55013: 2001+A1: 2003+A2:2006 
DISTANCE 
Source 
(Meters) 
FREQUENCY 
(MHz) 
Limits(dB
μV/m)  
Quasi-Peak 
1000 
Fundamental 60 
30~300 
  Harmonics 52 
Local Oscillator 
300~1000 
  Harmonics 56 
3 30~230 
40 
Other 
3 230~1000 
47 
Note: 
(1) Emission level = Antenna Factor + Cable Loss + Reading 
              (2) The lower limit shall apply at the transition frequencies. 
(3) Distance refers to the distance in meters between the test instrument 
antenna and the closed point of any part of the E.U.T. 
 
AMP 
Spectrum Analyzer
ANTENNA ELEVATION VARIES FROM 1 TO 4 METERS 
3m
TURN TABLE 
(FIBRE GLASS) 
2.0m(L)*1.0m(W)*0.8m(H)
Semi-anechoic 3m Chamber 
EUT
ABSORBER
Combining Network 
PC System 
Receiver 
(2.4m*2.4m)
R
 
AUDIX Technology (Shenzhen) Co., Ltd.
 
 
                                    Audix Technology (Shenzhen) Co., Ltd. Report No. ACS-E13288      page 50 of 401 
 
 
Test Standard: EN55022: 2010+A1:2011 
FREQUENCY 
(MHz) 
DISTANCE 
(Meters) 
FIELD STRENGTHS LIMITS 
(dB
μV/m) 
30 ~ 230 
10 
30 
230 ~ 1000 
10 
37 
1000~3000 3  70(Peak) 
50(Average) 
3000~6000 3  74(Peak) 
54(Average) 
Note: 
(1) Emission level = Antenna Factor + Cable Loss + Reading 
          Emission level = Antenna Factor -Amp Factor +Cable Loss + Reading 
(above 1000MHz) 
(2) The lower limit shall apply at the transition frequencies. 
 
(3) Distance refers to the distance in meters between the test instrument 
antenna and the closed point of any part of the E.U.T. 
5.5. EUT Configuration on Test 
The configurations of EUT are listed in Section 3.5. 
5.6. Operating Condition of EUT 
5.6.1. Setup the EUT and simulators as shown in Section 5.2. 
5.6.2. Turn on the power of all equipments. 
5.6.3. Let the EUT work in test modes (BD Live / FM 88MHz/ FM 98MHz/ FM 108MHz) 
and test it. 
5.7. Test Procedure 
The EUT was placed on a non-metallic table, 80 cm above the ground plane inside a 
semi-anechoic chamber. An antenna was located 3m from the EUT on an adjustable mast. 
A pre-scan was first performed in order to find prominent radiated emissions. For final 
emissions measurements at each frequency of interest, the EUT were rotated and the 
antenna height was varied between 1m and 4m in order to maximize the emission. 
Measurements in both horizontal and vertical polarities were made and the data was 
recorded. In order to find the maximum emission, the relative positions of equipments and 
all the interface cables were changed according to EN55013 and EN 55022 Class B on 
Radiated Disturbance test. 
 
The bandwidth setting on the test receiver (R&S TEST RECEIVER ESVS10) is 120 kHz. 
The resolution bandwidth of the Agilent Spectrum Analyzer E4407B was set at 1MHz. (For 
above 1GHz) 
The frequency range from 30MHz to 1000MHz was pre-scanned with a peak detector and 
all final readings of measurement from Test Receiver are Quasi-Peak values. 
 
The frequency range from 1GHz to 6GHz was checked and all final readings of 
measurement were with Peak and Average detector, measurement distance was 3m at 
semi-anechoic chamber. The portion of the test volume that was obstructed by absorber 
placed on the floor (30cm maximum). 
 
Finally, selected operating situations at Anechoic Chamber measurement, all the test results 
are listed in section 5.8. 
R
 
AUDIX Technology (Shenzhen) Co., Ltd.
 
 
                                    Audix Technology (Shenzhen) Co., Ltd. Report No. ACS-E13288      page 51 of 401 
 
 
5.8. Radiated Emission Test Results 
PASS. (All emissions not reported below are too low against the prescribed limits.) 
 
For frequency range 30MHz~1000MHz 
The EUT with the following test modes were tested and selected (mode 1~5) to read Q.P 
values, all the test results listed in next pages. 
 
EUT: BLU-RAY DISC SYSTEM              Model No. : BDS580 
 
Test Date: May.25~Jun.02, 2013        Temperature: 24℃    Humidity: 59% 
 
The details of test mode as follows: 
Reference Test Data No. 
No. Test 
Mode 
Horizontal Vertical 
1.  
BD Live(LAN)
#2 #1 
2. 
BD Live(WiFi)
#3 #4 
3. FM 
88MHz 
#31 
#32 
4. FM 
98MHz 
#35 
#36 
5. FM 
108MHz 
#34 
#33 
(※Worst test mode) 
 
For frequency range 1GHz~6GHz 
The EUT with below test modes were measured within Anechoic Chamber and the test 
results listed in next pages 
 
Test Date: Jun.02, 2013         Temperature: 24℃    Humidity: 56% 
The details of test mode as follows: 
Reference Test Data No. 
No. Test 
Mode 
Horizontal Vertical 
1. 
BD Live 
#2 #1 
2. Wi-Fi 
Mode 
#3 #4 
(※Worst test mode) 
R
 
AUDIX Technology (Shenzhen) Co., Ltd.
 
 
                                    Audix Technology (Shenzhen) Co., Ltd. Report No. ACS-E13288      page 52 of 401 
 