4. CONDUCTED DISTURBANCE AT TELECOMMUNICATION
PORTS TEST
4.1. Test Equipments
Item
Equipment
Manufacturer
Model No.
Serial No.
Last Cal. Cal. Interval
9. Test Receiver Rohde & Schwarz
ESHS10
838693/001
Oct.31, 12
1 Year
10.
L.I.S.N.#1
Rohde & Schwarz ESH2-Z5
834066/011
Oct.31, 12
1 Year
11.
L.I.S.N.#3
Kyoritsu
KNW-242C
8-1920-1
May.08, 13
1 Year
12. Terminator Hubersuhner
50
Ω
No. 1
May.08, 13
1 Year
13. Terminator Hubersuhner
50
Ω
No. 2
May.08, 13
1 Year
14.
RF Cable
Fujikura
3D-2W
No.1
May.08, 13
1Year
15. Coaxial Switch
Anritsu
MP59B
M50564
May.08, 13
1 Year
16.
Pulse Limiter Rohde & Schwarz ESH3-Z2
100341
May.08, 13
1 Year
4.2. Block Diagram of Test Setup
4.3. Test Standard
EN 55022: 2010+AC: 2011
4.4. Conducted Disturbance at Telecommunication Ports Limit
Maximum RF Line Voltage
Frequency
Quasi-Peak Level
dB(
μV)
Average Level
dB(
μV)
150kHz ~ 500kHz
84~74
74~64
500kHz ~ 30MHz
74
64
Notes: 1. * Decreasing linearly with logarithm of frequency.
2. The lower limit shall apply at the transition frequencies.
4.5. EUT Configuration on Test
The configurations of EUT are listed in Section 3.5
4.6. Operating Condition of EUT
4.6.1. Setup the EUT and simulators as shown in Section 4.2.
4.6.2. Turn on the power of all equipments.
4.6.3. The EUT link to PC and which transmitted data via running “TFGEN.exe”
4.6.2. Turn on the power of all equipments.
4.6.3. The EUT link to PC and which transmitted data via running “TFGEN.exe”
software., In order to make reliable emission measurement representative of high
LAN utilization it is only necessary to create a condition of LAN utilization in excess
of 10% and sustain that level for a minimum of 250ms.
LAN utilization it is only necessary to create a condition of LAN utilization in excess
of 10% and sustain that level for a minimum of 250ms.
4.6.4. The other peripheral devices were driven and operated in turn during all testing.
EUT
LISN #1
PC System
LISN #3
0.8m
80cm
Receiver
ISN
AE
:50
Ω Terminator; a: Lan Line
a
a
R
AUDIX Technology (Shenzhen) Co., Ltd.
Audix Technology (Shenzhen) Co., Ltd. Report No. ACS-E13288 page 44 of 401
4.7. Test Procedure
The EUT was placed on a non-metallic table, 80cm above the ground plane. The EUT
Power connected to the power mains through a line impedance stabilization network
(L.I.S.N. #1). This provided a 50-ohm coupling impedance for the EUT (Please refer to
the block diagram of the test setup and photographs). The other peripheral devices power
cord connected to the power mains through a line impedance stabilization network
(L.I.S.N.#3). Both sides of power line were checked for maximum conducted interference.
In order to find the maximum emission, the relative positions of equipments and all of the
interface cables were changed according to EN 55022: 2010+AC:2011 on Conducted
Disturbance test.
And connected to the telecommunication ports through ISN. Both sides of
telecommunication line are investigated to find out the maximum conducted emission
according to EN 55022: 2010+AC:2011 regulations during conducted disturbance test.
The bandwidth of the test receiver (R&S Test Receiver ESHS 10) is set at 10kHz.
The frequency range from 150kHz to 30MHz is checked. The test result are reported on
Section 4.8.
Power connected to the power mains through a line impedance stabilization network
(L.I.S.N. #1). This provided a 50-ohm coupling impedance for the EUT (Please refer to
the block diagram of the test setup and photographs). The other peripheral devices power
cord connected to the power mains through a line impedance stabilization network
(L.I.S.N.#3). Both sides of power line were checked for maximum conducted interference.
In order to find the maximum emission, the relative positions of equipments and all of the
interface cables were changed according to EN 55022: 2010+AC:2011 on Conducted
Disturbance test.
And connected to the telecommunication ports through ISN. Both sides of
telecommunication line are investigated to find out the maximum conducted emission
according to EN 55022: 2010+AC:2011 regulations during conducted disturbance test.
The bandwidth of the test receiver (R&S Test Receiver ESHS 10) is set at 10kHz.
The frequency range from 150kHz to 30MHz is checked. The test result are reported on
Section 4.8.
4.8. Conducted Disturbance at Telecommunication Ports Test Results
PASS.
The EUT with the following test modes were tested to read Q.P values and average values,
all the test results are listed in next pages.
EUT: BLU-RAY DISC SYSTEM Model Number: BDS580
Test Date: Jun.06, 2013 Temperature: 26.1℃ Humidity: 65%
The details of test mode as follows:
all the test results are listed in next pages.
EUT: BLU-RAY DISC SYSTEM Model Number: BDS580
Test Date: Jun.06, 2013 Temperature: 26.1℃ Humidity: 65%
The details of test mode as follows:
No.
Test Port
Test Mode
Reference Test Data No.
1. 10Mbps
#30
2.
ISN
100Mbps #29
Click on the first or last page to see other BDS 280 (serv.man4) service manuals if exist.