4.  CONDUCTED DISTURBANCE AT TELECOMMUNICATION 
PORTS TEST 
4.1.  Test Equipments 
Item 
Equipment 
Manufacturer 
Model No.
Serial No. 
Last Cal.  Cal. Interval
9.    Test Receiver  Rohde & Schwarz
ESHS10 
838693/001 
Oct.31, 12 
1 Year 
10.   
L.I.S.N.#1 
Rohde & Schwarz ESH2-Z5 
834066/011 
Oct.31, 12 
1 Year 
11.   
L.I.S.N.#3 
Kyoritsu 
KNW-242C
8-1920-1 
May.08, 13 
1 Year 
12.   Terminator  Hubersuhner 
50
Ω 
No. 1 
May.08, 13 
1 Year 
13.   Terminator  Hubersuhner 
50
Ω 
No. 2 
May.08, 13 
1 Year 
14.   
RF Cable 
Fujikura 
3D-2W 
No.1 
May.08, 13 
1Year 
15.    Coaxial Switch 
Anritsu 
MP59B 
M50564 
May.08, 13 
1 Year 
16.   
Pulse Limiter  Rohde & Schwarz ESH3-Z2 
100341 
May.08, 13 
1 Year 
4.2.  Block Diagram of Test Setup 
 
4.3.  Test Standard 
EN 55022: 2010+AC: 2011 
4.4.  Conducted Disturbance at Telecommunication Ports Limit 
Maximum RF Line Voltage 
Frequency 
Quasi-Peak Level 
dB(
μV) 
Average Level 
dB(
μV) 
150kHz ~ 500kHz 
84~74 
74~64 
500kHz ~ 30MHz 
74 
64 
Notes: 1. * Decreasing linearly with logarithm of frequency. 
2. The lower limit shall apply at the transition frequencies. 
4.5.  EUT Configuration on Test 
The configurations of EUT are listed in Section 3.5 
4.6.  Operating Condition of EUT 
4.6.1. Setup the EUT and simulators as shown in Section 4.2. 
4.6.2. Turn on the power of all equipments. 
4.6.3. The EUT link to PC and which transmitted data via running “TFGEN.exe”           
software., In order to make reliable emission measurement representative of high 
LAN utilization it is only necessary to create a condition of LAN utilization in excess 
of 10% and sustain that level for a minimum of 250ms.   
4.6.4. The other peripheral devices were driven and operated in turn during all testing. 
EUT
LISN #1
PC System
LISN #3
0.8m
80cm
Receiver
ISN 
AE 
:50
Ω Terminator;    a: Lan Line 
a
a
R
 
AUDIX Technology (Shenzhen) Co., Ltd.
 
 
                                    Audix Technology (Shenzhen) Co., Ltd. Report No. ACS-E13288      page 44 of 401 
 
 
4.7.  Test Procedure 
The EUT was placed on a non-metallic table, 80cm above the ground plane. The EUT 
Power connected to the power mains through a line impedance stabilization network 
(L.I.S.N. #1). This provided a 50-ohm coupling impedance for the EUT (Please refer to 
the block diagram of the test setup and photographs). The other peripheral devices power 
cord connected to the power mains through a line impedance stabilization network 
(L.I.S.N.#3). Both sides of power line were checked for maximum conducted interference. 
In order to find the maximum emission, the relative positions of equipments and all of the 
interface cables were changed according to EN 55022: 2010+AC:2011 on Conducted 
Disturbance test. 
And connected to the telecommunication ports through ISN. Both sides of 
telecommunication line are investigated to find out the maximum conducted emission 
according to EN 55022: 2010+AC:2011 regulations during conducted disturbance test. 
 
The bandwidth of the test receiver (R&S Test Receiver ESHS 10) is set at 10kHz. 
 
The frequency range from 150kHz to 30MHz is checked. The test result are reported on 
Section 4.8. 
4.8.  Conducted Disturbance at Telecommunication Ports Test Results 
PASS. 
 
The EUT with the following test modes were tested to read Q.P values and average values, 
all the test results are listed in next pages. 
 
EUT: BLU-RAY DISC SYSTEM            Model Number: BDS580 
 
Test Date: Jun.06, 2013    Temperature: 26.1℃    Humidity: 65% 
 
The details of test mode as follows: 
No. 
Test Port 
Test Mode 
Reference Test Data No.
1. 10Mbps 
#30 
2. 
ISN 
100Mbps #29 
 
Page of 127