Harman Kardon AVR 760 (serv.man2) EMC - CB Certificate ▷ View online
Harman Kardon Inc. Page 13 of 192
AVR760 (Harman Kardon)
EMC Test Report
Reference No.: NK08E 683.EMS
10.3 Test Log
Point Voltage
Coupling
Result
(Pass/Fail)
HCP, VCP
±
2, 4 kV
Contact Discharge
Pass
Top, Rear, Sides
±
2, 4 kV
Contact Discharge
Pass
Screw
±
2, 4 kV
Contact Discharge
Pass
RCA Jack
±
2, 4 kV
Contact Discharge
Pass
The Bridge Port
±
2, 4 kV
Contact Discharge
Pass
Headphone Jack
±
2, 4 kV
Contact Discharge
Pass
S-Video, HDMI Jack
±
4, 8 kV
Air Discharge
Pass
Front Panel
±
4, 8 kV
Air Discharge
Pass
Front (Button & Volume) Knobs
±
4, 8 kV
Air Discharge
Pass
Power Cord Bushing
±
4, 8 kV
Air Discharge
Pass
Enclosure (Non Conductive surface)
±
4, 8 kV
Air Discharge
Pass
Comment/Performance
No operation errors were detected during or after the discharges
Result
Compliant
Harman Kardon Inc. Page 14 of 192
AVR760 (Harman Kardon)
EMC Test Report
Reference No.: NK08E 683.EMS
11. Radio-frequency, Electromagnetic Field Keyed Carrier Immunity test (EN61000-4-3)
11.1 Test criteria and test procedure
Operating environment;
Temperature:
23 ℃
Relative Humidity:
40 %
The tests were performed at 3m distance in an anechoic chamber.
For floor-standing equipment, the EUT was mounted non-conducting support 0.1 m above the
supporting plane. For tabletop equipment, the EUT was located on a wooden table 0.8 m above the floor.
The EUT was exposed to the field from different angles, normally 0°, 90°, 180°, 270°
and at both horizontal and vertical polarization(antenna height 1.75 m)
A signal level of 3 V/m, duty cycle 1/8 pulse modulated with a 217 Hz sine wave was applied in the
frequency range 900 MHz. During the test the 1 kHz unwanted noise level comes from the speaker was
detected using microphone and selected level meter
For floor-standing equipment, the EUT was mounted non-conducting support 0.1 m above the
supporting plane. For tabletop equipment, the EUT was located on a wooden table 0.8 m above the floor.
The EUT was exposed to the field from different angles, normally 0°, 90°, 180°, 270°
and at both horizontal and vertical polarization(antenna height 1.75 m)
A signal level of 3 V/m, duty cycle 1/8 pulse modulated with a 217 Hz sine wave was applied in the
frequency range 900 MHz. During the test the 1 kHz unwanted noise level comes from the speaker was
detected using microphone and selected level meter
Instrumentation used during this session:
Instruments
Manufacturer
Model
Serial number Due to Calibration
Signal Generator
R & S
SMY01
830766/032
2009.03
Function Generator
H.P
33120A
US36042890
2009.01
Power Amplifier
Noiseken
NA25MF1G2010C
A00518
2009.10
Power Amplifier
Noiseken
NA15K80M50C
A00518
2009.10
Power Sensor
HP
8482A
US37293322
2009.03
Power Sensor
HP
8482A
US37293323
2009.03
Power Meter
HP
E4419B
GB39511164
2009.03
Biconical log Antenna
ARA
LPB-2520/A
1180
2009.01
Selective Level Meter
Anritsu
ML422B
M18572
2009.06
11.2 Test Parameters
Port:
Enclosure
Test Engineer:
J. Y. Yu
Basic Standard: EN 61000-4-3:2002+A1: 2002
Performance Criteria:
A
Dwell Time :
120 sec
Frequency Range :
900 MHz
Modulation :
1/8 Duty PM @ 217 Hz
Test Level
3 Vrms
Harman Kardon Inc. Page 15 of 192
AVR760 (Harman Kardon)
EMC Test Report
Reference No.: NK08E 683.EMS
11.3 Test Log
Frequency
Range
( MHz )
Position
(Angle)
Polarity
(H or V)
Field
Strength
( Vrms )
Modulation
Result
(Pass/Fail)
900
Front
H
3
Duty Cycle 1/8 PM@217 Hz
Pass
900
Rear
H
3
Duty Cycle 1/8 PM@217 Hz
Pass
900
Right
H
3
Duty Cycle 1/8 PM@217 Hz
Pass
900
Left
H
3
Duty Cycle 1/8 PM@217 Hz
Pass
900
Front
V
3
Duty Cycle 1/8 PM@217 Hz
Pass
900
Rear
V
3
Duty Cycle 1/8 PM@217 Hz
Pass
900
Right
V
3
Duty Cycle 1/8 PM@217 Hz
Pass
900
Left
V
3
Duty Cycle 1/8 PM@217 Hz
Pass
Comment/Performance
The criterion of compliance with the requirement is satisfied with a wanted to unwanted audio signal ratio
of ≥40 dB at a wanted audio signal level of 500mV.
of ≥40 dB at a wanted audio signal level of 500mV.
Result
Compliant
Harman Kardon Inc. Page 16 of 192
AVR760 (Harman Kardon)
EMC Test Report
Reference No.: NK08E 683.EMS
12. Fast Transients/Burst (EN 61000-4-4)
12.1 Test criteria and test procedure
Operating environment;
Temperature:
20 ℃
Relative Humidity:
40 %
The minimum area of the ground reference plane is 1 m x 1 m, and connected to earth via a low impedance connection.
The EFT/Burst generator was located on the ground reference plane.
The EUT was located 0.1 m above the ground reference plane. The minimum distance between the EUT and all other
conductive structures, except the ground reference plane is more than 0.5 m.
The test voltage was applied simultaneously between each of the power supply conductors and the protective earth at the
power supply.
The EFT/Burst generator was located on the ground reference plane.
The EUT was located 0.1 m above the ground reference plane. The minimum distance between the EUT and all other
conductive structures, except the ground reference plane is more than 0.5 m.
The test voltage was applied simultaneously between each of the power supply conductors and the protective earth at the
power supply.
Instrumentation used during this session:
.
Instruments
Manufacturer
Model
Serial Number Due to Calibration
EFT/Burst Simulator
Noiseken
FNS-AXⅡB50
0199B01147
2008. 12
Clamp
Noiseken
FNS-AXⅡB50
N/A
2008. 12
12.2 Test Parameters
Port :
AC Mains
Test Engineer:
J. Y. Yu
Basic Standard : EN 61000-4-4:2004
Performance Criteria:
B
Duration :
120 sec
Test Data :
Tr/Th 5/50 ns Fburst 5 kHz Trep 300 ms
12.3 Test Log
Line Voltage
Coupling
Inject Time
( Sec )
Result
(Pass/Fail)
L1
0.5, 1 kV
Direct
120
Pass
L2
0.5, 1 kV
Direct
120
Pass
L1+ L2
0.5, 1 kV
Direct
120
Pass
Comment/Performance
Degradation of sound qualities were detected during the testing, but any degradation of quality
was not detected after the testing.
was not detected after the testing.
Result
Compliant