Harman Kardon AVR 760 (serv.man2) EMC - CB Certificate ▷ View online

 
Harman Kardon Inc.                                                Page 13 of 192 
                                                                            AVR760 (Harman Kardon)
 
EMC Test Report 
Reference No.: NK08E 683.EMS 
 
 
10.3  Test Log 
 
Point Voltage 
Coupling 
Result 
(Pass/Fail)
 HCP, VCP 
±
2, 4 kV 
Contact Discharge 
Pass 
  Top, Rear, Sides 
±
2, 4 kV 
Contact Discharge 
Pass 
 Screw 
±
2, 4 kV 
Contact Discharge 
Pass 
 RCA Jack 
±
2, 4 kV 
Contact Discharge 
Pass 
 The Bridge Port 
±
2, 4 kV 
Contact Discharge 
Pass 
 Headphone Jack 
±
2, 4 kV 
Contact Discharge 
Pass 
  S-Video, HDMI Jack 
±
4, 8 kV 
Air Discharge 
Pass 
 Front Panel 
±
4, 8 kV 
Air Discharge 
Pass 
  Front (Button & Volume) Knobs 
±
4, 8 kV 
Air Discharge 
Pass 
 Power Cord Bushing 
±
4, 8 kV 
Air Discharge 
Pass 
  Enclosure (Non Conductive surface)
±
4, 8 kV 
Air Discharge 
Pass 
 
 
Comment/Performance 
No operation errors were detected during or after the discharges 
 
Result 
Compliant 
 
Harman Kardon Inc.                                                Page 14 of 192 
                                                                            AVR760 (Harman Kardon)
 
EMC Test Report 
Reference No.: NK08E 683.EMS 
 
 
11. Radio-frequency, Electromagnetic Field Keyed Carrier Immunity test (EN61000-4-3) 
 
11.1 Test criteria and test procedure 
 
      Operating environment; 
 Temperature: 
23  ℃ 
 
Relative Humidity: 
40 % 
 
 
The tests were performed at 3m distance in an anechoic chamber.   
For floor-standing equipment, the EUT was mounted non-conducting support 0.1 m above the 
supporting plane. For tabletop equipment, the EUT was located on a wooden table 0.8 m above the floor. 
The EUT was exposed to the field from different angles, normally 0°, 90°, 180°, 270° 
and at both horizontal and vertical polarization(antenna height 1.75 m) 
A signal level of 3 V/m, duty cycle 1/8 pulse modulated with a 217 Hz sine wave was applied in the   
frequency range 900 MHz. During the test the 1 kHz unwanted noise level comes from the speaker was   
detected using microphone and selected level meter 
 
Instrumentation used during this session: 
 
Instruments 
Manufacturer
Model 
Serial number  Due to Calibration
Signal Generator 
R & S 
SMY01 
830766/032 
2009.03 
Function Generator 
H.P 
33120A 
US36042890 
2009.01 
Power Amplifier 
Noiseken 
NA25MF1G2010C 
A00518 
2009.10 
Power Amplifier 
Noiseken 
NA15K80M50C 
A00518 
2009.10 
Power Sensor 
HP 
8482A 
US37293322 
2009.03 
Power Sensor 
HP 
8482A 
US37293323 
2009.03 
Power Meter 
HP 
E4419B 
GB39511164 
2009.03 
Biconical log Antenna 
ARA 
LPB-2520/A 
1180 
2009.01 
Selective Level Meter 
Anritsu 
ML422B 
M18572 
2009.06 
 
 
11.2 Test Parameters 
 Port: 
Enclosure 
 
Test Engineer: 
J. Y. Yu 
 Basic Standard:  EN 61000-4-3:2002+A1: 2002 
Performance Criteria: 
 Dwell Time : 
120 sec 
 
Frequency Range : 
900 MHz 
Modulation : 
1/8 Duty PM @ 217 Hz 
Test Level 
3 Vrms 
 
 
 
 
 
 
Harman Kardon Inc.                                                Page 15 of 192 
                                                                            AVR760 (Harman Kardon)
 
EMC Test Report 
Reference No.: NK08E 683.EMS 
 
 
11.3  Test Log 
 
Frequency 
Range  
( MHz ) 
Position 
(Angle) 
Polarity 
(H or V) 
Field 
Strength 
( Vrms ) 
Modulation 
Result  
(Pass/Fail)
900
 
Front
 
H
 
3
 
Duty Cycle 1/8 PM@217 Hz
 
Pass 
900
 
Rear
 
H
 
3
 
Duty Cycle 1/8 PM@217 Hz
 
Pass 
900
 
Right
 
H
 
3
 
Duty Cycle 1/8 PM@217 Hz
 
Pass 
900
 
Left
 
H
 
3
 
Duty Cycle 1/8 PM@217 Hz
 
Pass 
900
 
Front
 
V
 
3
 
Duty Cycle 1/8 PM@217 Hz
 
Pass 
900
 
Rear
 
V
 
3
 
Duty Cycle 1/8 PM@217 Hz
 
Pass 
900
 
Right
 
V
 
3
 
Duty Cycle 1/8 PM@217 Hz
 
Pass 
900
 
Left
 
V
 
3
 
Duty Cycle 1/8 PM@217 Hz
 
Pass 
 
Comment/Performance 
The criterion of compliance with the requirement is satisfied with a wanted to unwanted audio signal ratio 
of ≥40 dB at a wanted audio signal level of 500mV. 
 
Result 
Compliant 
 
Harman Kardon Inc.                                                Page 16 of 192 
                                                                            AVR760 (Harman Kardon)
 
EMC Test Report 
Reference No.: NK08E 683.EMS 
 
 
12. Fast Transients/Burst (EN 61000-4-4) 
 
12.1 Test criteria and test procedure 
 
      Operating environment; 
 Temperature: 
20  ℃ 
 
Relative Humidity: 
40 % 
 
The minimum area of the ground reference plane is 1 m x 1 m, and connected to earth via a low impedance connection.   
The EFT/Burst generator was located on the ground reference plane. 
The EUT was located 0.1 m above the ground reference plane. The minimum distance between the EUT and all other 
conductive structures, except the ground reference plane is more than 0.5 m. 
The test voltage was applied simultaneously between each of the power supply conductors and the protective earth at the 
power supply. 
 
Instrumentation used during this session: 
Instruments 
Manufacturer
Model 
Serial Number  Due to Calibration
 EFT/Burst Simulator 
Noiseken 
FNS-AXⅡB50
0199B01147 
2008. 12 
 Clamp 
Noiseken 
FNS-AXⅡB50
N/A 
2008. 12 
 
12.2 Test Parameters 
    Port : 
AC Mains 
 
Test Engineer: 
J. Y. Yu 
  Basic Standard : EN 61000-4-4:2004 
Performance Criteria: 
    Duration : 
120 sec 
 
 
 
  Test Data : 
Tr/Th   5/50 ns      Fburst   5 kHz    Trep   300 ms 
 
12.3  Test Log 
 
Line Voltage 
Coupling 
Inject Time 
( Sec ) 
Result  
(Pass/Fail) 
L1 
0.5, 1 kV 
Direct 
120 
Pass 
L2 
0.5, 1 kV 
Direct 
120 
Pass 
L1+ L2 
0.5, 1 kV 
Direct 
120 
Pass 
 
Comment/Performance 
Degradation of sound qualities were detected during the testing, but any degradation of quality 
was not detected after the testing. 
 
Result 
Compliant 