DOWNLOAD Harman Kardon AVR 7500 (serv.man9) Service Manual ↓ Size: 1.98 MB | Pages: 54 in PDF or view online for FREE

Model
AVR 7500 (serv.man9)
Pages
54
Size
1.98 MB
Type
PDF
Document
EMC - CB Certificate
Brand
Device
Audio
File
avr-7500-sm9.pdf
Date

Harman Kardon AVR 7500 (serv.man9) EMC - CB Certificate ▷ View online

 
IEC 60065, 6th edition : 1998
 - 
- Page 33 of 43 - 
 
 
   
 
Order No. 
200211175
 
 
 
 
B.10.1 
Insulation between TNV terminals 
and antenna terminals (including 
interconnection terminals which may 
be connected to equipment with 
antenna terminals) withstands the 
50 discharges of 10.1   
 
B.14.12 
Surge suppressors between TNV 
circuits and other parts of the 
equipment have breakdown voltage 
at least 1,8 times the mains voltage   
 
 
IEC 60065, 6th edition : 1998
 - 
- Page 34 of 43 - 
 
 
   
 
Order No. 
200211175
 
 
 
 
 
LIST OF CRITICAL COMPONENTS 
 
Part No 
Component/ 
Object 
Manufacturer 
Type / Model 
Ratings / 
Technical Data 
Complies 
with the 
following 
standard 
Marks of 
conformity 
granted ** 
 
Main 
transformer 
 
Cross-over 
tubing Mtl. 
 
Thermal   
cut-out 
Power Technics Co. 
 
 
Daikin Industries Co. 
 
 
Seki Controls Co. Ltd. 
5541185A 
 
 
PTFE tube 
 
 
ST-22 
230V, Class B 
 
 
180C, 94V-0 
Min 0,5mm thick 
 
5A/250V
, 145C
 
IEC60065 
clause 14.3 
 
UL94 
 
 
IEC60730 
1.) 
 
 
UL 
 
 
VDE 
T451 
Sub 
transformer 
 
Bobbin Mtl. 
Power Technics Co. 
   
 
Toray Industries Inc. 
55288770NR 
 
 
Various 
230V, Class E 
 
 
Min. 94V-0 
IEC60065 
clause 14.3 
 
UL94 
1.) 
 
 
UL 
Sec. 
componen
Line filter 
Power Technics Co. 
55411860NR 
500uH x 2, 
Class E 
IEC60065 
clause 14.3 
1.) 
R452, 
R476 
 
Bridging 
resistor for 
mains relay 
D. I. Electronics Co. 
RQD 
10 
 / 30W, 
IEC60065 
clause 14.1 
1.) 
For 
CENELEC 
c
ountries  
Mains plug 
with cord 
TA HSING 
TA-17 
H05VV-F 
10/16A 250V 
1.5mm
2
 (cord) 
IEC60884-1 
S, VDE 
For UK 
Mains plug   
with cord 
Not evaluated, ref. 
Summary of testing 
   
   
   
   
F451, 
F507, 
F508 
Fuse 
alt. 
alt. 
alt. 
Littelfuse Triad Inc. 
Schurter AG. 
Samjoo Enterprise. 
Sun Electric Co. Ltd. 
50T, 5x20mm 
FST, 5x20mm 
50T, 5x20mm 
5T, 5x20mm 
T1.25A L 250V 
IEC60127 
S, VDE 
F452 
Mains fuse 
alt. 
alt. 
alt. 
Littelfuse Triad Inc. 
Schurter AG. 
Samjoo Enterprise. 
Sun Electric Co. Ltd. 
50T, 5x20mm 
FST, 5x20mm 
50T, 5x20mm 
5T, 5x20mm 
T6.3A L 250V 
IEC60127 
S, VDE 
F453 
Fuse 
alt. 
alt. 
alt. 
Littelfuse Triad Inc. 
Schurter AG. 
Samjoo Enterprise. 
Sun Electric Co. Ltd. 
50T, 5x20mm 
FST, 5x20mm 
50T, 5x20mm 
5T, 5x20mm 
T500mA L 250V 
IEC60127 
S, VDE 
F501, 
F502 
Fuse 
alt. 
alt. 
alt. 
Littelfuse Triad Inc. 
Schurter AG. 
Samjoo Enterprise. 
Sun Electric Co. Ltd. 
50T, 5x20mm 
FST, 5x20mm 
50T, 5x20mm 
5T, 5x20mm 
T1.6A L 250V 
IEC60127 
S, VDE 
**) Marks listed under “Marks of conformity granted” indicates that Nemko has verified certifications respectively 
1.) Tested as part of the Apparatus according to EN 60 065 / IEC 60065, 6.Edition : 1998 
 
IEC 60065, 6th edition : 1998
 - 
- Page 35 of 43 - 
 
 
   
 
Order No. 
200211175
 
 
 
 
 
LIST OF CRITICAL COMPONENTS (continued) 
 
Part No 
Component/ 
Object 
Manufacturer 
Type / Model 
Ratings / 
Technical Data 
Complies 
with the 
following 
standard 
Marks of 
conformity 
granted ** 
F503, 
F504, 
F505, 
F506 
Mains fuse 
alt. 
alt. 
alt. 
Littelfuse Triad Inc. 
Schurter AG. 
Samjoo Enterprise. 
Sun Electric Co. Ltd. 
50T, 5x20mm 
FST, 5x20mm 
50T, 5x20mm 
5T, 5x20mm 
T3.15A L 250V 
IEC60127 
S, VDE 
SW719 
Mains switch 
Matsushita Electronic. 
Y1 
(ESB91511A) 
8A/128A 250V 
IEC60065 
IEC61058-1 
N, VED 
RLY451 
RLY452 
RLY453 
Mains relay 
alt. 
Original Electromecha. 
Original Electromecha. 
SDT-S-112DMR
 
SDT-S-112DMR 
8A/120A 250V 
IEC61058-1 
IEC 60065 

C461 
X-capacitor 
alt. 
alt. 
alt. 
alt. 
Pilkor Electronics. 
Pilkor Electronics. 
ISKRA Elect. 
Okaya Electric Inc. 
Yuchang Electronics. 
Ultra Tech Xiphi. 
PCX2 335M 
PCX2 335 
KNB1530 
RE104 
WBU1942 
HXQ 
0.10uF 275V 
X2 
IEC60384-
14, 2
nd
 ed. 
S, VDE 
 
C451, 
C459, 
C460, 
C469, 
C470 
X-capacitor 
alt. 
alt.   
alt. 
alt. 
Korea Electronics 
Netron Tech. 
Sam Wha Capacitor. 
JYH CHUNG 
Murata Mfg. 
NU 
AA 
SC 
JY 
KH 
0.0047uF/250V 
X1/Y2 
IEC60384-
14, 2
nd
 ed. 
S, VDE 
 
Mains 
socket-outlet 
Dae Ryung Electronic 
A3-02-D006 
2.5A/250V 
IEC 60884-1 
 
PCB 
Various 
Various 
Min 94V-1 
UL 796 
UL 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
Comments 
 
 
**) Marks listed under “Marks of conformity granted” indicates that Nemko has verified certifications respectively 
1.) Tested as part of the Apparatus according to EN 60 065 / IEC 60065, 6.Edition : 1998 
 
IEC 60065, 6th edition : 1998
 - 
- Page 36 of 43 - 
 
 
   
 
Order No. 
200211175
 
 
 
 
 
FAULT CONDITION TESTS   
Ambient temperature   
  24,0 °C 
Rated voltage   
230V~ 50Hz   
Remarks   
Comp. 
No 
Fault 
Test V 
Position 
Test time  Fuse No 
Current 
through 
fuse 
Mains power/temperatures/results 
D452 
 
S-c 
254,4 
~ - + 
1 sec 
F452 
F452 opened immediately. 
No hazard.   
D452 
 
S-c 
207 
~ - + 
1 sec 
F452 
F452 opened immediately. 
No hazard.   
C457 
 
S-c 
254,4 
1 sec 
F452 
F452 opened immediately. 
No hazard.   
C457 
 
S-c 
207 
1 sec 
F452 
F452 opened immediately. 
No hazard.   
D455 
S-c 
254,4 
A - C 
30 min 
F453 
Protection circuit operated 
immediately (
RLY451, RLY452
 
off
). 
F453 opened.   
Input current stabilised at 0,02A. 
No hazard.   
D455 
S-c 
207 
A - C 
30 min 
F453 
Protection circuit operated after   
3 sec. (RLY451, RLY452 off). 
F453 opened.   
Input current stabilised at 0,01A. 
No hazard.   
D453 
 
S-c 
254,4 
A - C 
30 min 
F453 
2.36 A 
Normal operating. 
Input current stabilised at 2,35A. 
No component damaged. 
No hazard.   
D453 
 
S-c 
207 
A - C 
30 min 
F453 
2,22 A 
Normal operating. 
Input current stabilised at 2,20A. 
No component damaged. 
No hazard.   
C466 
S-c 
254,4 
30 min 
F453 
Protection circuit operated 
immediately (
RLY451, RLY452 off
). 
F453 opened.   
Input current stabilised at 0,02A. 
No hazard.   
C466 
S-c 
207 
30 min 
F453 
Protection circuit operated 
immediately (
RLY451, RLY452 off
). 
F453 opened.   
Input current stabilised at 0,01A. 
No hazard.   
F No = Fault Number, S-c = Short-circuit, Dis = Disconnection
 
Page of 54
Display