Harman Kardon AVR 7300 EMC - CB Certificate ▷ View online

 - 
IEC 60065, 6th edition : 1998
 - 
- Page 33 of 40 - 
 
 
   
 Order 
No. 
24775
 
 
 
 
 
LIST OF CRITICAL COMPONENTS 
 
Part No 
Component/ 
Object 
Manufacturer 
Type / Model 
Ratings / 
Technical Data 
Complies 
with the 
following 
standard 
Marks of 
conformity 
granted **
- Main 
transf. 
 
 
Tubing 
 
Insulation 
 
T
hermal cut-out
 
Power Technics. 
 
 
Daikin Ind. Co., Ltd 
 
SKC Co., Ltd. 
 
Seki Controls Co. 
H01
-
TXPWMMD10B0
 
 
F-201 
 
SR-55 
 
ST-22 
230V, Class E 
 
 
V-0, 180
°
C, 
PTFE 
 
VTM-2, 130
°
 
5A/250V
145
°
IEC60065 
clause 14.3
 
UL94 
 
UL94 
 
IEC60730 
1.) 
 
 
UL, 
E52460
 
UL, 
E74359
 
VDE 
T451 Sub 
transf. 
 
 
Bobbin Mtl. 
alt. 
 
Bobbin Cap 
 
Thermal fuse 
Orientech Co., Ltd 
 
 
LG Chemical Ltd. 
Sam Yang Co., Ltd.
 
EI Dupont. 
 
Uchihashi Estec. 
H01
-
TXPWMSD10A0
 
 
GP-2306F 
1551GN-30 
 
101F 
 
323 
230V, Class B 
 
 
V-0, 140
°
C, PBT 
V-0, 140
°
C, PBT 
 
V-2, 130
°
C, 
PA66
 
 
130
°
C, 1A/250V 
IEC60065 
clause 14.3
 
UL94 
UL94 
 
UL94 
 
IEC60691 
1.) 
 
 
UL, 
E67171
UL, 
E121254
 
UL, 
E41938
 
VDE 
T452 Reactor 
 
Bobbin 
 
Bobbin Cap 
 
Thermal fuse 
alt. 
Power Technics. 
 
Toray Industries. 
 
Toray Industries. 
 
Uchihashi Estec. 
Anzen Dengu Co. 
RE-7300 
 
1104G-30 
 
3004G-30 
 
225R 
L7 
230V, Class E 
 
V-0, 130
°
C, PBT 
 
V-0, 120
°
C, 
PA66
 
 
150
°
C, 250V, 5A 
150
°
C, 250V, 5A 
IEC60065 
 
UL94 
 
UL94 
 
IEC60691 
IEC60691 
1.) 
 
UL, 
E41797
 
UL, 
E41797
 
VDE 
VDE 
NJ81 A
ppliance inlet
 Zhangjiagang 
 
Huajie Electronics 
SA-4S 10A/250V~ 
IEC60320 
VDE 
NJ82 Mains 
Socket outlet 
Dae Ryung Elect. 
A3-04-D007 
2.5A / 250V~ 
IEC60884-1
NEMKO 
Mains switch 
Alps Electric Co. 
SDL1P-D 
5A/80A250V 
IEC61058-1
VDE 
SK1, 
SK2, 
SK41 
Mains relay 
Tyco Electronic. 
SDT-S-112DMR 
8A/120A 250V 
IEC61058-1
IEC60065 
SEMKO 
F451 
(outlet) 
Mains fuse 
alt. 
alt. 
alt. 
Littelfuse. 
Orisel Co., Ltd. 
Schurter AG. 
Sun Electronics. 
218 
50T 
SFT 
5T 
T1.6A L 250V 
IEC60127 
VDE 
VDE 
VDE 
VDE 
F452 Mains 
fuse 
alt. 
alt. 
Littelfuse. 
Orisel Co., Ltd. 
Suzhou Littelfuse. 
215 
55T 
215 
T8A H 250V 
IEC60127 
VDE 
VDE 
VDE 
**) Marks listed under “Marks of conformity granted” indicates that Nemko has verified certifications respectively 
1.) Tested as part of the Apparatus according to EN 60 065 / IEC 60065, 6.Edition : 1998 
 - 
IEC 60065, 6th edition : 1998
 - 
- Page 34 of 40 - 
 
 
   
 Order 
No. 
24775
 
 
 
 
 
LIST OF CRITICAL COMPONENTS (continued)
 
Part No 
Component/ 
Object 
Manufacturer 
Type / Model 
Ratings / 
Technical Data 
Complies 
with the 
following 
standard 
Marks of 
conformity 
granted ** 
F453 Sec. 
fuse 
 
alt. 
alt. 
alt. 
Littelfuse. 
Orisel Co., Ltd. 
Schurter AG. 
Sun Electronics. 
218 
50T 
SFT 
5T 
T800mA L 250V 
IEC60127 VDE 
VDE 
VDE 
VDE 
F200 - 
F207 
 
F454, 
F455 
Sec. fuse 
Littelfuse. 
Save Fusetech. 
Save Fusetech. 
BEL Fuse Ltd. 
Schurter AG 
0663 
SR-5 
SS-5 
MRT 
MST 
T2A L 250V 
IEC60127 
VDE 
VDE 
VDE 
VDE 
VDE 
C461 X-capacitor 
alt. 
alt. 
alt. 
alt. 
alt. 
Pilkor Electronics. 
Pilkor Electronics. 
ISKRA Elect. 
Okaya Electric Inc. 
Yuchang Electronics. 
Ultra Tech Xiphi. 
PCX2 335M 
PCX2 335 
KNB1530 
RE104 
WBU1942 
HQX 
0.10uF 275V 
X2 
IEC60384-14, 
2
nd
 ed. 
VDE 
VDE 
VDE 
VDE 
VDE 
VDE 
C451, 
C459, 
C460, 
C469, 
C470 
X-capacitor 
alt. 
alt.  
alt. 
alt. 
Du San Industrial. 
Netron Tech. 
Sam Wha Capacitor. 
JYH CHUNG 
Murata Mfg. 
NU 
AA 
SC 
JY 
KH 
0.0047uF/250V 
X1/Y2 
IEC60384-14, 
2
nd
 ed. 
VDE 
VDE 
VDE 
VDE 
VDE 
PCB 
Various 
Various 
Min 94V-1 
UL 796 
UL 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 Comments 
**) Marks listed under “Marks of conformity granted” indicates that Nemko has verified certifications respectively 
1.) Tested as part of the Apparatus according to EN 60 065 / IEC 60065, 6.Edition : 1998 
 - 
IEC 60065, 6th edition : 1998
 - 
- Page 35 of 40 - 
 
 
   
 Order 
No. 
24775
 
 
 
 
 
FAULT CONDITION TESTS   
Ambient temperature   
 25,4 °C 
Rated voltage   
230V~ 50Hz   
Remarks  
Comp. 
No 
Fault 
Test V 
Position 
Test time
Fuse No
Current 
through 
fuse 
Mains power/temperatures/results 
D204 
S-c 
253,0 
AC – + 
20 min 
F452, 
F200, 
F201 
3,51 A 
Normal operated. 
Input current stabilised at 3,51A. 
F200 opened. 
No hazard.   
C244 S-c  253,0 - 
10 
min 
F452, 
F200, 
F201 
5,10 A 
Output signal off immediately. 
Input current stabilised at 1,47A. 
F200, F201 opened. 
No hazard.   
C244 S-c  207,0 - 
10 
min 
F452, 
F200, 
F201 
3,90 A 
Output signal off immediately. 
Input current stabilised at 1,20A. 
F200, F201 opened. 
No hazard.   
C213 S-c  253,0 - 
30 
min 
F452, 
F200, 
F201 
2,80 A 
L channel output (Front, Surr, S/B) 
off immediately. 
Input current stabilised at 2,70A. 
R201 opened. 
No hazard.   
C213 S-c  207,0 - 
10 
min 
F452, 
F200, 
F201 
2,78 A 
L channel output (Front, Surr, S/B) 
off immediately. 
Input current stabilised at 2,60A. 
R201 opened. 
No hazard.   
C214 S-c  253,0 - 
10 
min 
F452, 
F200, 
F201 
3,00 A 
L channel output (Front, Surr, S/B) 
off immediately. 
Input current stabilised at 2,70A. 
R201 opened. 
No hazard.   
D203 
S-c 
253,0 
AC – + 
10 min 
F452, 
F202, 
F203 
4,60 A 
Normal operated. 
Input current stabilised at 3,50A. 
F202 opened. 
No hazard. 
C242 S-c  253,0 - 
10 
min 
F452, 
F202, 
F203 
3,80 A 
Normal operated. 
Input current stabilised at 3,50A. 
F202, F203 opened. 
No hazard. 
F No = Fault Number, S-c = Short-circuit, Dis = Disconnection
 
 - 
IEC 60065, 6th edition : 1998
 - 
- Page 36 of 40 - 
 
 
   
 Order 
No. 
24775
 
 
 
 
 
FAULT CONDITION TESTS (continued)   
Comp. 
No 
Fault 
Test V 
Position 
Test time
Fuse No
Current 
through 
fuse 
Mains power/temperatures/results 
C219 S-c  253,0 - 
10 
min 
F452, 
F202, 
F203 
3,90 A 
Normal operated. 
Input current stabilised at 3,50A. 
R203 opened. 
No hazard. 
C219 S-c  207,0 - 
10 
min 
F452, 
F202, 
F203 
3,74 A 
Normal operated. 
Input current stabilised at 3,43A. 
R203 opened. 
No hazard. 
C220 S-c  253,0 - 
10 
min 
F452, 
F202, 
F203 
2,49 A 
Normal operated. 
Input current stabilised at 3,49A. 
No component damaged. 
No hazard. 
C228 S-c  253,0 - 
10 
min 
F452, 
F202, 
F203 
3,59 A 
Normal operated. 
Input current stabilised at 3,52A. 
R207 opened. 
No hazard. 
C229 S-c  253,0 - 
10 
min 
F452, 
F202, 
F203 
3,59 A 
Normal operated. 
Input current stabilised at 3,51A. 
R207 opened. 
No hazard. 
D202 
S-c 
253,0 
AC – + 
10 min 
F452, 
F204, 
F205 
3,54 A 
Normal operated. 
Input current stabilised at 3,52A. 
F204 opened. 
No hazard. 
C241 S-c  253,0 - 
10 
min 
F452, 
F204, 
F205, 
1,50 A 
Output signal off immediately. 
Input current stabilised at 1,40A. 
F204, F205 opened. 
No hazard. 
C231 S-c  253,0 - 
10 
min 
F452, 
F204, 
F205, 
3,60 A 
Output signal off immediately. 
Input current stabilised at 1,30A.   
F204, F205 opened. 
No hazard. 
C231 S-c  207,0 - 
40 
min 
F452, 
F204, 
F205, 
3,60 A 
Output signal off immediately. 
Input current stabilised at 1,07A.   
F204, F205, R208 opened. 
No hazard. 
C233 S-c  253,0 - 
20 
min 
F452, 
F204, 
F205, 
3,55 A 
Normal operated. 
Input current stabilised at 3,52A. 
No component damaged. 
No hazard. 
F No = Fault Number, S-c = Short-circuit, Dis = Disconnection
 
Page of 52
Display