Harman Kardon AVR 7300 EMC - CB Certificate ▷ View online

 - 
IEC 60065, 6th edition : 1998
 - 
- Page 21 of 40 - 
 
 
   
 Order 
No. 
24775
 
 
 
 
14.3.5.1 
Class II transformers have adequate 
insulation between hazardous live 
parts and accessible parts (double or 
reinforced insulation)   
Double or reinforced insulation between hazardous live 
windings and accessible conductive parts. 
 
Coil formers and partition walls 
 0,4 mm   
Sub transformer, type H01-TXPWMSD10A0; 
The bobbin fulfils the requirement of reinforced insulation,
thickness: > 0,4 mm. 
14.3.5.2 
Class I transformers have adequate 
insulation between hazardous live 
parts and accessible conductive 
parts or those conductive parts or 
protective screens connected to a 
protective earth terminal   
Windings of Class II construction used. 
 
Winding wires connected to 
protective earth have adequate 
current-carrying capacity   
 
14.4 
High voltage components 
 
 
 
High-voltage components and 
assemblies: U > 4 kV (peak) 
separately approved   
No high voltage components used 
 
Component meets category FV 1 of 
IEC 60 707   
 
14.4.1 
High voltage transformers and 
multipliers tested as part of the 
submission  
 
14.5 Protective 
devices 
 
 
 
Protective devices used within their 
ratings  
Thermal cut-out, thermal links and fuses 
 
External clearance and creepage 
distances appropriate for the voltage 
across the device when opened   
 
14.5.1.1 
a) Thermal cut-outs separately 
approved  
Automatic (built-in main transformer) : 
Manufacturer.  : Seki Controls Co., Ltd. 
Type : 
ST-22 
 
Certified by 
: VDE according to IEC60730 
 
b) Thermal cut-outs tested as part of 
the submission   
 
14.5.1.2 
a) Thermal links separately 
approved  
a) Built-in sub transformer: 
Manufacturer  : Uchihashi Estec Co., Ltd. 
Type : 
323 
Certified by 
: VDE according to IEC60691
 
 
b) Built-in reactor: 
Manufacturer  : Uchihashi Estec Co., Ltd. 
Type : 
225R 
Certified by 
: VDE according to IEC60691 
 - 
IEC 60065, 6th edition : 1998
 - 
- Page 22 of 40 - 
 
 
   
 Order 
No. 
24775
 
 
 
 
 
b) Thermal links tested as part of the 
apparatus  
 
14.5.1.3 
Thermal devices resettable by 
soldering  
No such thermal device 
14.5.2.1 
Fuse-links in the mains circuit 
according to IEC 60 127   
See list below 
Circuit M
anufacturer
Dimen- Approved
Marking 
of 
Marking Current 
diagram 
 
sions 
by 
rated current, 
close to 
through 
informa- 
 
 
 
pre-arcing time 
the com- 
the fuse   
tion 
 
 
 
and current 
ponent 
in normal 
Part No 
 
 
 
characteristic 
 
operation 
F451 (pr.) 
Littelfuse. 
5
××××
20mm, 218
xxx
VDE 
T1.6A L 250V 
T1.6A L 250V 
0,80 A*) 
F452 (pr.) 
Littelfuse. 
5
××××
20mm, 215
xxx
VDE 
T8A H 250V 
T8A H 250V 
3,51 A   
F453 (sec.) 
Littelfuse. 
5
××××
20mm, 218
xxx
VDE 
T800mA L 250V 
T800mA L 250V 
0,45 A 
F454, F455 (sec.) 
Littelfuse. 8.5
φφφφ
, 0663 
VDE 
T2A 250V 
T2A L 250V 
0,65 A 
F200, F201 (sec.) 
Littelfuse. 8.5
φφφφ
, 0663 
VDE 
T2A 250V 
T2A L 250V 
0,25 A 
F202, F203 (sec.) 
Littelfuse. 8.5
φφφφ
, 0663 
VDE 
T2A 250V 
T2A L 250V 
1,30 A 
F204, F205 (sec.) 
Littelfuse. 8.5
φφφφ
, 0663 
VDE 
T2A 250V 
T2A L 250V 
0,60 A 
F206, F207 (sec.) 
Littelfuse. 8.5
φφφφ
, 0663 
VDE 
T2A 250V 
T2A L 250V 
0,60 A 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
*) Calculated through current for mains socket-outlet: SWITCHD 100W + UNSWITCHD 100W (200W total). 
14.5.2.2 
Correct marking of fuse-links 
adjacent to holder      
Correct marking applied close to the fuse, see table 
above. 
14.5.2.3 
Not possible to connect fuses in 
parallel    
No fuse holder so designed that fuse-links can be 
connected in parallel 
14.5.2.4 
Not possible to touch hazardous live 
parts when replacing fuse-links 
without the use of a tool     
No replacement of fuse possible by hand. 
 
14.5.3 
PTC-S thermistors comply with 
IEC 60 738   
No PTC’s 
 
PTC-S devices (>15 W) category 
FV 1 or better   
 
14.5.4 
Other protective devises. 
Circuit protectors have adequate 
breaking capacity and their position 
is correctly marked   
No other protective devices 
14.6 Switches 
 
 
 
Manually operated mechanical 
switch (MOMS) conductively 
connected to the mains
 
 
 
 - 
IEC 60065, 6th edition : 1998
 - 
- Page 23 of 40 - 
 
 
   
 Order 
No. 
24775
 
 
 
 
Part No 
Function 
Manufacturer 
Type 
Rated Marking 
 
All- 
One 
Name 
Trademark 
 
V A Surge 
 
pole 
pole 
 
 
 
  current
 
 
 
 
 
 
 
 
 
 x 
Alps 
Elect.  - 
SDL1P-D  250 
80A 
SK1, SK2, SK41 
 
Tyco Electronic. 
OEG 
SDT-S-112DMR  250 
120A 
 
 
 
 
 
 
 
 
 
14.6.1 
Permanently connected equipment 
provided with an all-pole mains 
switch unless 5.4.2 is met   
Apparatus is not permanently connected 
 
14.6.2 
Manually operated mechanical 
switch (MOMS), required where 
power consumption > 15 W and/or 
peak voltage > 4 kV 
Yes. MOMS required. See table above. 
 
Switch readily accessible and not in 
mains cord   
Switch located on the front and readily accessible 
 
Exception for automatic switching   
 
 
Exception for continuous operation   
 
14.6.3 
Manually operated mechanical 
switch (MOMS): Switch indication / 
On position clearly discernible   
The display is illuminated. 
 
Indication by marking meets Cl. 5   
Yes 
 
Indication of the OFF position   
Off-position marked with “OFF” 
14.6.4 
Manually operated mechanical 
switch (MOMS) fitted. Is there a 
Stand-by mode      
Yes 
 
Stand-by mode clearly discernible    
LED indication 
 
Exception for low Stand-by current 
< 0,7 mA (peak)   
 
14.6.5 
Components bridging contacts of 
mains switches comply with 14.1 a) 
or 14.2.2   
Yes. See clause 14.2. 
14.6.6.a. 
Manually operated mechanical 
switches (MOMS) separately 
approved to IEC 61 058-1   
Yes, certified by VDE. 
14.6.6.b. 
Manually operated mechanical 
switch (MOMS) tested as part of the 
equipment complies with 14.6.7, 
14.6.10 and 20.1.4 and meets 14.6.8 
and/or 14.6.9 and Annex G (G1.1)   
 
 
Flame test for mains switches   
 
14.6.7 Endurance 
test 
 
14.6.8 
Temperature rise in mains switch 
 
 - 
IEC 60065, 6th edition : 1998
 - 
- Page 24 of 40 - 
 
 
   
 Order 
No. 
24775
 
 
 
 
14.6.9 
Dielectric strength test 
 
14.6.10 
Surge current for mains switches 
also controlling mains socket-outlets
Measured surge current through, 
- Mains switch 
: LT 1A, 
- Mains relay, SK1 and SK2  : 17A, 
- Mains relay, SK41 
: 50A *. 
 
The measured and surge current value is less than rated 
surge current rating of the mains switch and relays - OK. 
 
*) Surge current value for switched outlet, 100W = 50A. 
14.7 Safety 
interlocks 
 
 
 
Safety interlocks to 2.8 of 
IEC 60 950   
No safety interlock 
14.8 
Voltage setting devices 
 
 
 
Voltage setting device not likely to be 
changed accidentally   
No voltage selector 
 
14.9 Motors 
 
 
14.9.1 
Endurance test on motors   
No motors 
 
 
Motor start test   
 
 
Dielectric strength test   
 
14.9.2 
Not adversely affected by oil or 
grease etc.   
 
14.9.3 
Protection against moving parts   
No moving parts 
14.9.4 
Motors with phase-shifting 
capacitors, three-phase motors and 
series motors meet Cl. B.8, B.9 and 
B.10 of IEC 60 950, Annex B   
 
14.10 Batteries 
 
 
14.10.1 
Batteries mounted with no risk of 
accumulation of flammable gases   
No batteries 
 
14.10.2 
No possibility of recharging non-
rechargeable batteries   
 
14.10.3 
Recharging currents and times 
within manufacturers limits   
 
 
Lithium batteries discharge and 
reverse currents within the 
manufacturers limits   
 
14.11 Optocouplers 
 
 
 
Optocouplers comply with Cl. 8   
No optocouplers. 
 