Report No.: 215445
ATTACHMENT 4
Clause
Requirement + Test
Result - Remark
Verdict
TRF No. IEC60065K
Cont.
Zx.4 Requirements for listening devices (headphones and earphones)
Zx.4.1 Wired listening devices with analogue
input
With 94 dBA sound pressure output L
input
With 94 dBA sound pressure output L
Aeq,T
, the input
voltage of the fixed “programme simulation noise”
described in EN 50332-2 shall be ≥ 75 mV.
described in EN 50332-2 shall be ≥ 75 mV.
This requirement is applicable in any mode where
the headphones can operate (active or
passive), including any available setting (for
example built-in volume level control).
the headphones can operate (active or
passive), including any available setting (for
example built-in volume level control).
NOTE The values of 94 dBA – 75 mV correspond with 85dBA –
27 mV and 100 dBA – 150 mV.
27 mV and 100 dBA – 150 mV.
No portable sound system.
N/A
Zx.4.2 Wired listening devices with digital input
With any playing device playing the fixed “
programme simulation noise” described in
EN 50332-1 (and respecting the digital interface
standards, where a digital interface standard exists
that specifies the equivalent acoustic level), the
acoustic output L
With any playing device playing the fixed “
programme simulation noise” described in
EN 50332-1 (and respecting the digital interface
standards, where a digital interface standard exists
that specifies the equivalent acoustic level), the
acoustic output L
Aeq,T
of the listening device shall
be ≤ 100 dBA.
This requirement is applicable in any mode where the
headphones can operate, including any available
setting (for example built-in volume level control,
additional sound feature like equalization, etc.).
headphones can operate, including any available
setting (for example built-in volume level control,
additional sound feature like equalization, etc.).
NOTE An example of a wired listening device with digital input is
a USB headphone.
a USB headphone.
No portable sound system.
N/A
Zx.4.3 Wireless listening devices
In wireless mode:
In wireless mode:
with any playing and transmitting device playing
the fixed programme simulation noise described in
EN 50332-1; and
the fixed programme simulation noise described in
EN 50332-1; and
respect
ing the wireless transmission standards,
where an air interface standard exists that specifies
the equivalent acoustic level; and with volume and
sound settings in the listening device (for example
built-in volume level control, additional sound
feature like equalization, etc.) set to the
combination of positions that maximize the
measured acoustic output for the above-mentioned
programme simulation noise, the acoustic output
L
the equivalent acoustic level; and with volume and
sound settings in the listening device (for example
built-in volume level control, additional sound
feature like equalization, etc.) set to the
combination of positions that maximize the
measured acoustic output for the above-mentioned
programme simulation noise, the acoustic output
L
Aeq,T
of the listening device shall be ≤ 100 dBA.
NOTE An example of a wireless listening device is a Bluetooth
headphone.
headphone.
No portable sound system.
N/A
Zx.5 Measurement methods
Measurements shall be made in accordance with
EN 50332-1 or EN 50332-2 as applicable.
Unless stated otherwise, the time interval T shall be
30 s.
Measurements shall be made in accordance with
EN 50332-1 or EN 50332-2 as applicable.
Unless stated otherwise, the time interval T shall be
30 s.
NOTE Test method for wireless equipment provided without
listening device should be defined.
listening device should be defined.
No portable sound system.
N/A
Page 8 of 15
Report No.: 215445
ATTACHMENT 4
Clause
Requirement + Test
Result - Remark
Verdict
TRF No. IEC60065K
6.1
(
(
A11:2008)
Replace the entire subclause in EN 60065:2002
and EN 60065:2002/A1:2006 by:
Ionizing radiation
Apparatus including a potential source of ionizing
radiation shall be so constructed that personal
protection against ionizing radiation is provided
under normal operating conditions and under fault
conditions.
Compliance is checked by measurement under the
following conditions:
In addition to the normal operating conditions, all
controls adjustable from the outside BY HAND, by
any object such as a tool or a coin, and those
internal adjustments or pre-sets which are not
locked in a reliable manner, are adjusted so as to
give maximum radiation whilst maintaining an
intelligible picture for 1 h, at the end of which the
measurement is made.
NOTE 1 Soldered joints and paint lockings are
examples of adequate locking.
The dose-rate is determined by means of a
radiation monitor with an effective area of 10 cm²,
at any point 10 cm from the outer surface of the
apparatus.
Moreover, the measurement shall be made under
fault conditions causing an increase of the high-
voltage, provided an intelligible picture is
maintained for 1 h, at the end of which the
measurement is made.
The dose-rate shall not exceed 1μSv/h (0,1 mR/h)
taking account of the background level.
NOTE 2 These values appear in Directive
96/29/Euratom of 13th May 1996.
A picture is considered to be intelligible if the
following conditions are met:
and EN 60065:2002/A1:2006 by:
Ionizing radiation
Apparatus including a potential source of ionizing
radiation shall be so constructed that personal
protection against ionizing radiation is provided
under normal operating conditions and under fault
conditions.
Compliance is checked by measurement under the
following conditions:
In addition to the normal operating conditions, all
controls adjustable from the outside BY HAND, by
any object such as a tool or a coin, and those
internal adjustments or pre-sets which are not
locked in a reliable manner, are adjusted so as to
give maximum radiation whilst maintaining an
intelligible picture for 1 h, at the end of which the
measurement is made.
NOTE 1 Soldered joints and paint lockings are
examples of adequate locking.
The dose-rate is determined by means of a
radiation monitor with an effective area of 10 cm²,
at any point 10 cm from the outer surface of the
apparatus.
Moreover, the measurement shall be made under
fault conditions causing an increase of the high-
voltage, provided an intelligible picture is
maintained for 1 h, at the end of which the
measurement is made.
The dose-rate shall not exceed 1μSv/h (0,1 mR/h)
taking account of the background level.
NOTE 2 These values appear in Directive
96/29/Euratom of 13th May 1996.
A picture is considered to be intelligible if the
following conditions are met:
- a scanning amplitude of at least 70 % of the
usable screen width;
- a minimum luminance of 50 cd/m² with locked
blank raster provided by a test generator;
- a horizontal resolution corresponding to at least
1,5 MHz in the centre, with a similar vertical
degradation;
degradation;
- not more than one flashover per 5 min.
No CRT
N/A
Page 9 of 15
Report No.: 215445
ATTACHMENT 4
Clause
Requirement + Test
Result - Remark
Verdict
TRF No. IEC60065K
Z1
(A11:2008)
(A11:2008)
Add the following new clause after Clause 20:
Z1 Resistance to candle flame ignition
A television set shall be so designed that the
likelihood of ignition and the spread of fire caused
by a candle flame is reduced.
NOTE 1 An apparatus with a viewing screen is not
regarded to be a television set if it is declared not to
be so by the manufacturer.
This requirement does not apply to the display
screen of rear projection TV’s.
NOTE 2 This exemption has been allowed because
this technology is falling out of use and it is
expected that within a few years it will no longer
exist. This exemption will not be extended to other
technologies.
NOTE 3 The frame around the screen is not
exempted from the requirements.
Wood and WOOD-BASED MATERIAL with a
thickness of at least 6 mm is considered to fulfil the
V-1 requirement when applying CLC/TS 62441.
Compliance is checked according to CLC/TS
62441.
NOTE 4 The term vertical, as used in the first dash
of clause 5.2 of CLC/TS 62441, does not mean a
perfectly vertical position. It should be interpreted
as any surface that can be touched by the flame of
a candle of 150 mm height and 20mm diameter
while the candle is still touching the supporting
surface. A typical candle used in the home is
assumed to be 20 mm diameter.
NOTE 5 It is expected that CLC/TS 62441 will in
the future be replaced by a standard, at which time
that standard will become applicable, subject to a
vote by National Committees at the time.
Z1 Resistance to candle flame ignition
A television set shall be so designed that the
likelihood of ignition and the spread of fire caused
by a candle flame is reduced.
NOTE 1 An apparatus with a viewing screen is not
regarded to be a television set if it is declared not to
be so by the manufacturer.
This requirement does not apply to the display
screen of rear projection TV’s.
NOTE 2 This exemption has been allowed because
this technology is falling out of use and it is
expected that within a few years it will no longer
exist. This exemption will not be extended to other
technologies.
NOTE 3 The frame around the screen is not
exempted from the requirements.
Wood and WOOD-BASED MATERIAL with a
thickness of at least 6 mm is considered to fulfil the
V-1 requirement when applying CLC/TS 62441.
Compliance is checked according to CLC/TS
62441.
NOTE 4 The term vertical, as used in the first dash
of clause 5.2 of CLC/TS 62441, does not mean a
perfectly vertical position. It should be interpreted
as any surface that can be touched by the flame of
a candle of 150 mm height and 20mm diameter
while the candle is still touching the supporting
surface. A typical candle used in the home is
assumed to be 20 mm diameter.
NOTE 5 It is expected that CLC/TS 62441 will in
the future be replaced by a standard, at which time
that standard will become applicable, subject to a
vote by National Committees at the time.
No television set
N/A
General 13.3.1
Delete note 4.
14
Delete note 4 and note 5.
15.1.1
Delete notes 1 and 2.
15.2
Delete note 2.
16.1
Delete note 1.
16.2
Delete the note.
20
Delete note 2.
Annex B
Replace note 1 by: In the CENELEC countries listed in IEC 62151,
special national conditions apply.
Annex G
Delete the note.
Annex J.2
Delete the notes of Table J.1.
Annex N
Add after the introduction: For ROUTINE TEST reference is made to
EN 50333. (Replaced by EN 50514)
—
Page 10 of 15
Report No.: 215445
ATTACHMENT 4
Clause
Requirement + Test
Result - Remark
Verdict
TRF No. IEC60065K
General
(A2:2010)
(A2:2010)
In IEC 60065:2001/A2
Delete all the “country” notes according to the following list:
5.3
Delete all the “country” notes according to the following list:
5.3
Note
5.4.1 Note
20
20
Note
For special national conditions, see Annex ZB.
—
Bibliograph
y
y
Additional EN standards.
—
ZA
Normative references to international publications
with their corresponding European publications
—
ZB
ANNEX ZB TO EN 60065, SPECIAL NATIONAL CONDITIONS (EN)
2.6.1
DK: The following is added:
Certain types of CLASS I apparatus, see 15.1.1,
may be provided with a plug not establishing
earthing continuity when inserted in Danish socket-
outlets
Justification: Heavy Current Regulations, Section
107.
Certain types of CLASS I apparatus, see 15.1.1,
may be provided with a plug not establishing
earthing continuity when inserted in Danish socket-
outlets
Justification: Heavy Current Regulations, Section
107.
Class II apparatus.
N/A
3.Z1
(A2:2010)
(A2:2010)
Denmark
Add to the end of the subclause
Due to many existing installations where the
socket-outlets can be protected with
fuses with higher rating than the rating of the
socket-outlets the protection for
pluggable equipment type A shall be an integral
part of the equipment.
Justification:
In Denmark an existing 13 A socket outlet can be
protected by a 20 A fuse.
Add to the end of the subclause
Due to many existing installations where the
socket-outlets can be protected with
fuses with higher rating than the rating of the
socket-outlets the protection for
pluggable equipment type A shall be an integral
part of the equipment.
Justification:
In Denmark an existing 13 A socket outlet can be
protected by a 20 A fuse.
No socket-outlets.
N/A