DOWNLOAD Harman Kardon AVR 370 (serv.man4) Service Manual ↓ Size: 7.49 MB | Pages: 107 in PDF or view online for FREE

Model
AVR 370 (serv.man4)
Pages
107
Size
7.49 MB
Type
PDF
Document
EMC - CB Certificate
Brand
Device
Audio
File
avr-370-sm4.pdf
Date

Harman Kardon AVR 370 (serv.man4) EMC - CB Certificate ▷ View online

 
Page 15 of 15 
Report No.: 215445 
 
 
ATTACHMENT 4 
Clause 
Requirement + Test 
Result - Remark 
Verdict 
       
TRF No. IEC60065K 
J.2 
NO: After Table J.1 the following is added: 
In Norway, due to the IT power distribution system 
used, the a.c. MAINS supply voltage is considered 
to be equal to the line-to-line voltage, and will 
remain 230 V in case of a single earth fault. 
Justification: Based on a use in Norway of an IT 
power distribution system where the neutral is not 
provided. 
Noted. 
 
 
ZC 
ANNEX ZC TO EN 60065, A-DEVIATIONS (EN) 
 
5.1 
 
IT: Additional markings on the outside of the TV 
receiver in Italian language 
Not TV set. 
N/A 
 
IT:User instructions in Italian language including a 
conformity declaration 
 
N/A 
 
IT: Certification number on the back cover 
 
N/A 
6.1 
 
DE: The following requirement applies: 
For the operation of any cathode ray tube intended 
for the display of visual images operating at an 
acceleration voltage exceeding 40 kV, authorization 
is required, or application of type approval 
(Bauartzulassung) and marking. 
Justification: German ministerial decree against 
ionizing radiation (Röntgenverordnung), in force 
since 2002-07-01, implementing the European 
Directive 96/29/EURATOM.  
NOTE Contact address: 
Physikalisch-Technische Bundesanstalt, 
Bundesallee 100, D-38116 Braunschweig, Tel.: 
Int+49-531-592-6320, Internet: http://www.ptb.de 
No CRT 
N/A 
14 
 
SE: Switches containing mercury such as 
thermostats, relays and level controllers are not 
allowed. 
Justification: Ordinance (1990:944) on Prohibition 
in Connection with handling. Importation and 
exportation of Chemical Products (Certain Cases) 
No such switches 
P 
 
 
 
Page 1 of 5 
Report No.: 215445 
 
 
ATTACHMENT 5 
Clause 
Requirement + Test 
Result - Remark 
Verdict 
       
TRF No. IEC60065K 
ANNEX TO TEST REPORTS 
REGULATORY REQUIREMENTS FOR SINGAPORE 
 
Annex Form No. .............................. :  SG_RR_A 
Annex Form Originator ..................... :  TÜV SÜD PSB Pte Ltd 
Master Annex Form .......................... :  2008-03 
Copyright © 2008 IEC System for Conformity Testing and Certification of Electrical Equipment 
(IECEE), Geneva, Switzerland. All rights reserved. 
 
No 
Items 
Requirements 
Result - Remark 
Verdict 
The following is the national differences in accordance with safety authority website 
www.spring.gov.sg/safety, ref. Singapore Consumer Protection (Safety Requirements) – Information 
Booklet – Chapter 7. 
7 SAFETY AUTHORITY’S REQUIREMENTS 
The Safety Authority monitors the safety of the controlled goods sold in Singapore by 
investigating all complaints, incidents and accidents reported to the authority. Experiences gained 
are translated into the Safety Authority’s Requirements. These requirements are to be fulfilled in 
addition to the applicable safety standards. 
 
No 
Items 
Requirements 
Result - Remark 
Verdict 
Applicable to all products 
Test certificate 
/ Test report 
Test certificate / Test report more  
than three (3) years old shall be  
rejected. 
Noted — 
Controlled  
Goods 
incorporated  
with additional 
function 
The additional function must be  
tested to its applicable safety 
standard. 
 
N/A 
Applicable to all electrical products 
3 All 
appliances 
All appliances must be tested to 230 
VAC. 
Covered 
Voltage 
selector 
(voltage mis-
match test) 
Appliance fitted with voltage 
selector shall be tested as follows: 
Connect appliance to 230 VAC 
mains with voltage selector switch 
to settings not suitable for operation 
at 230 VAC. 
No voltage selector. 
N/A 
Tropical 
condition test 
All appliances (with tropical test 
requirements in applicable 
Standards) shall comply with the 
tropical condition test as stated in 
the relevant IEC Standards. 
Comply 
 
Page 2 of 5 
Report No.: 215445 
 
 
ATTACHMENT 5 
Clause 
Requirement + Test 
Result - Remark 
Verdict 
       
TRF No. IEC60065K 
Class I 
appliances 
(3-pin mains 
plug) 
All Class I appliances must be fitted 
with 3-pin mains plugs complied 
with SS 145/SS 472 that are 
registered with the Safety Authority.
Class II apparatus 
N/A 
Class II 
appliances 
(mains plug) 
a) All Class II appliances must be 
fitted with 2-pin mains plug 
(Appendix T) complied with EN 
50075. 
b) Class II appliances that are fitted 
with 3-pin mains plugs must use 
plugs that are complied with SS 145 
and registered with the Safety 
Authority. 
See appended table, list of  
critical components, and  
comments in Summary 
of Testing. 
Appliances 
rated ≥ 3 kW 
or connected 
to fixed wiring 
Electric appliance ≥ 3 kW must be 
connected to fixed wiring. All 
connection to fixed wiring must be 
in accordance with Code of Practice 
CP5. 
Not exceed 3kW 
N/A 
Detachable 
power cord 
set (consists 
of mains plug, 
mains cord 
and appliance 
connector 
Detachable power cord set must be 
listed in the test report critical 
component list. 
See appended table, list of  
critical components, and  
comments in Summary 
of Testing. 
10 
Circuit 
diagrams 
Circuit diagrams must be indicated 
with component’s values for 
products tested to IEC 60065 and 
IEC 60950. 
Comply 
11 
Circuit 
diagrams of 
electronic 
modules in 
electrical 
appliances 
Circuit diagrams of the electronic 
modules in the electrical appliances 
must be provided. 
No such module in the 
apparatus 
N/A 
12 
Controlled 
goods likely to 
be treated as 
toy by children 
Controlled goods, having an 
enclosure, which is shaped and 
decorated so that it is likely to be 
treated as a toy by children, shall 
not be accepted for certification and 
registration. 
Apparatus is not likely to be  
treated as a toy by children. 
N/A 
 
Page 3 of 5 
Report No.: 215445 
 
 
ATTACHMENT 5 
Clause 
Requirement + Test 
Result - Remark 
Verdict 
       
TRF No. IEC60065K 
No 
Items 
Requirements 
Result - Remark 
Verdict 
Applicable to electric airport 
13 Reboil 
Switch 
No part of the reboil switch is  
allowed to protrude into the water 
pot, even if it is located above the 
maximum water level mark. 
No electric airport 
N/A 
Applicable to AC adaptor 
14 
3-pin AC 
adaptor 
(Appendix V) 
Test report showing that the 3-pin 
complied with sub-clauses 12.1 & 
12.3 of SS 246 must be submitted. 
No AC adaptor 
N/A 
15 
2-pin AC 
adaptor 
(Appendix V) 
The 2-pin (Appendix T) shall comply 
with EN 50075. 
 N/A 
16 
Detachable 
power supply 
cord set not 
supplied by 
Registered 
Supplier 
Registered Supplier who is not 
supplying the detachable power 
supply cord set together with the 
AC Adaptor must provide written 
instruction to its customer on the 
type of approved detachable power 
cord set to use. 
 N/A 
Applicable to computer products 
17 
CD/DVD ROM 
(used in 
personal 
computer) 
Test certificate showing that 
CD/DVD ROM has complied with 
IEC 825 must be provided. 
No CD/DVD ROM. 
N/A 
18 
Modem Card 
(used in 
personal 
computer) 
Modem card incorporated in the 
personal computer must be tested 
at set level (sub-clauses 5.1 & 6 of 
IEC 60950) or at component level. 
No modem. 
N/A 
Applicable to ceiling fan and cycle fan 
19 
Ceiling fan 
and cycle fan 
a) These appliances must be tested 
to sub-clauses 5.7 and 5.8 of SS 
360: 1992. 
b) Installation instruction must 
mention the 3 expansion bolts for 
fastening the main suspension, 
safety cord, expansion bolt with 
hook for fastening safety cord and 
mounting plate. (Appendix Q) 
c) Drawing (Appendix P) to show 
that the wires within the motor shaft 
are not stressed must be provided. 
No ceiling fan and cycle fan. 
N/A 
Page of 107
Display