PDF
Document
EMC - CB Certificate
Brand
Device
Audio
File
avr-360-sm2.pdf
Date

Harman Kardon AVR 360 (serv.man2) EMC - CB Certificate ▷ View online

Ref. No.:
 
LR500120906Q
 
 Copyright 
c
 2009, LTA
 CO., LTD
 
Page 9 of 17 
 
 
  3.2.3 Fast Transients common mode 
     
Definition: 
    The test assesses the ability of the EUT to operate as intended in the event of fast transients presence on one of the 
input/output ports. 
We were performed the test according to LTA procedure QP-014. 
 
Test method 
:  EN 61000-4-4 
Cable length 
:  < 3 m 
Test level   
:    0,5 kV (Signal /control ports) 
1,0 kV (AC Power input port) 
Polarity : 
 
Negative/ 
positive 
Repetition frequency 
:    5  ㎑ 
Test mode 
:  PLAY mode 
Performance Criteria 
:    B (Refer to the appendix 1) 
Result 
:  
Complies
 
 
Measurement Data: 
- Uncertainty = +/- 10% (with a 95% confidence level, k=2) 
“It has been demonstrated that the EFT/Burst generator meets the specified requirements in the standard with at least 
95% confidence.” 
AC power Line 
Test level 
Result 
Remarks 
+ 1kV 
Complies 
No reaction recognized 
- 1kV 
Complies 
No reaction recognized 
+ 1kV 
Complies 
No reaction recognized 
- 1kV 
Complies 
No reaction recognized 
+ 1kV 
- 1kV 
+ 1kV 
Complies 
No reaction recognized 
L - N 
- 1kV 
Complies 
No reaction recognized 
+ 1kV 
L – PE 
- 1kV 
+ 1kV 
N-PE 
- 1kV 
+ 1kV 
L-N-PE 
- 1kV 
 
TEST EQUIPMENT USED:    13, 14, 15, 45 
Ref. No.:
 
LR500120906Q
 
 Copyright 
c
 2009, LTA
 CO., LTD
 
Page 10 of 17 
 
 
 
 
 
 
APPENDIX 1
     
 
PERFORMANCE CRITERIA 
     
 
Ref. No.:
 
LR500120906Q
 
 Copyright 
c
 2009, LTA
 CO., LTD
 
Page 11 of 17 
 
 
Performance criterion A:   
The equipment shall continue to operate as intended without operator intervention. No degradation 
of performance or loss of function is allowed below a performance level specified by the 
manufacturer when the equipment is used as intended. The performance level may be replaced by a 
permissible loss of performance. If the minimum performance level or the permissible performance 
loss is not specified by the manufacturer, then either of these may be derived from the product 
description and documentation, and by what the user may reasonably expect from the equipment if 
used as intended. 
 
Performance criterion B:   
After the test, the equipment shall continue to operate as intended without operator intervention. No 
degradation of performance or loss of function is allowed, after the application of the phenomena 
below a performance level specified by the manufacturer, when the apparatus is used as intended. 
The performance level may be replaced by a permissible loss of performance. During the test, 
degradation of performance is allowed. However, no change of operating state or stored data is 
allowed to persist after the test. If the minimum performance level (or the permissible performance 
loss) is not specified by the manufacturer, then either of these may be derived from the product 
description and documentation, and by what the user may reasonably expect from the equipment if 
used as untended. 
 
Performance criterion C:   
Loss of function is allowed, provided the function is self-recoverable or can be restored by the 
operating of the controls by the user In accordance with the manufacturer’s instructions. Functions, 
and/or information stored in non-volatile memory, or protected by a battery backup, shall not be lost. 
 
 
 
 
 
 
Ref. No.:
 
LR500120906Q
 
 Copyright 
c
 2009, LTA
 CO., LTD
 
Page 12 of 17 
 
 
 
 
 
 
APPENDIX 2
     
 
TEST EQUIPMENT AND ANCILLARIES USED FOR TESTS 
     