3.
Test Summary
3.1 Summary of tests
Parameter
Applied Standard
Status
I. Emission
Disturbance Voltage at the mains terminals
EN55013:2001+A1:2003+A2:2006
NA
Disturbance Voltage of ANT. terminal
EN55013:2001+A1:2003+A2:2006
NA
Wanted Signal & Disturbance Voltage at RF Output Terminal
EN55013:2001+A1:2003+A2:2006
NA
Disturbance power
EN55013:2001+A1:2003+A2:2006
NA
Radiated disturbances
EN55013:2001+A1:2003+A2:2006
NA
Harmonic Current emission
EN61000-3-2:2006
NA
Voltage fluctuations and flicker
EN61000-3-3:1995+A1:2001+A2:2005
NA
II. Immunity
RF Voltages(in differential mode):S1
EN55020:2007
NA
RF Voltages (in common mode):S2b
EN55020:2007
NA
RF Voltages( input interference):S2a
EN55020:2007
NA
Ambient Electromagnetic Fields:S3
EN55020:2007
NA
Screening Effectiveness: S4
EN55020:2007
NA
Electrostatic discharge
EN 61000-4-2:1995+A1:1998+A2:2001
C
RF e.m. Field Keyed carrier(900MHz)
EN 61000-4-3:2006+A1:2008
C
Electrical fast transients
EN 61000-4-4:2004
C
Note 1: C=Complies NC=Not Complies NT=Not Tested NA=Not Applicable
Note 2: The data in this test report are traceable to the national or international standards.
Ref. No.:
LR500120906Q
Copyright
○
c
2009, LTA
CO., LTD
Page 6 of 17
3.2 IMMUNITY
3.2.1 Electrostatic Discharge
Definition:
The test assesses the ability of the EUT to operate as intended in the event of an electrostatic discharge.
We were performed the test according to LTA procedure QP-014.
Test method
: EN 61000-4-2
Discharge Impedance
: 330
Ω ±10% / 150pF ±10%
Type of Discharge (air discharge)
:
± 2kV, ± 4kV, ± 8KV
Type of Discharge (contact discharge)
:
± 2kV, ± 4KV
Number of discharges at each point
: 10 of each polarity
Discharge Repetition on Rate
: 1 / sec
Test mode
: PLAY mode
Performance Criteria
: B (Refer to the appendix 1)
Result
:
Complies
Measurement Data:
- Uncertainty(ESD) = +/- 5% (with a 95% confidence level, k=2)
“It has been demonstrated that the ESD generator meets the specified requirements in the standard with at least 95%
confidence.”
- refer to the Next page
TEST EQUIPMENT USED: 12, 45
Ref. No.:
LR500120906Q
Copyright
○
c
2009, LTA
CO., LTD
Page 7 of 17
1. Indirect Discharge
No.
Position
Kind of Discharge
Results
Remarks
①
HCP Contact
Complies
No
reaction
recognized
②
VCP Contact
Complies
No
reaction
recognized
2. Direct Discharge
No.
Position
Kind of
Discharge
Results
Remarks
1 ENCLOSURE Contact
Complies No
reaction
recognized
2
SCREW
Contact Complies
No
reaction
recognized
3 PHONES Contact
Complies No reaction recognized
4 USB
Air
Complies
No
reaction
recognized
5 VIDEO Contact
Complies No reaction recognized
6
AUDOI (R/L)
Contact
Complies
No reaction recognized
7 RADIO
ANTENNAS Contact Complies No
reaction
recognized
8
RADIO (AM / GND)
Air
Complies
No reaction recognized
9 COMPONENT
VIDEO
Air
Complies No
reaction
recognized
10
A-BUS IR OUT
Air
Complies
No reaction recognized
11 CARRIER,
Air
Complies No
reaction
recognized
12
ZONE 2
Air
Complies
No reaction recognized
13 REMOTE
Air
Complies No
reaction
recognized
14
THE BRIDGE III
Contact
Complies No
reaction
recognized
15 HDMI
Air
Complies No
reaction
recognized
16 COMPONENT
OUT
Air Complies No
reaction
recognized
17 A-BUS
Air
Complies No
reaction
recognized
18
ZONE 2 OUT
Contact
Complies No
reaction
recognized
19 ANALOG
AUDIO Contact Complies
No
reaction
recognized
20
6/8 CHANNEL INPUT
Contact
Complies
No reaction recognized
21 DIGITAL
AUDIO Contact Complies No
reaction
recognized
22
DIGITAL AUDIO
(OPTICAL)
Air Complies
No
reaction
recognized
23 SPEAKERS
Air
Complies No
reaction
recognized
24
AC OUTLET
Air
Complies
No reaction recognized
25
ON / OFF SWITCH
Air
Complies
No reaction recognized
26
AC INPUT
Air
Complies
No reaction recognized
27
FRONT BUTTON
Air
Complies
No reaction recognized
TEST EQUIPMENT USED: 12, 45
Ref. No.:
LR500120906Q
Copyright
○
c
2009, LTA
CO., LTD
Page 8 of 17
3.2.2 RF e.m. field keyed carrier
Definition:
The test assesses the ability of the EUT to operate as intended in the presence of a radio frequency electromagnetic
field disturbance.
We were performed the test according to LTA procedure QP-014.
Test method
: EN 61000-4-3
Frequency range
: 900㎒ ±5㎒
Test level
: 3 V/m (measured unmodulated)
Duty cycle
: 1/8
Rep. frequency
: 217Hz
Test mode
: PLAY mode
Performance Criteria
: A (Refer to the appendix 1)
Result
:
Complies
Measurement Data:
- Uncertainty = +/- 1.6dB (with a 95% confidence level, k=2.28)
“It has been demonstrated that the RS generator meets the specified requirements in the standard with at least 95%
confidence.”
Result
Port
Test mode
Horizontal
Vertical
Remark
Enclosure PLAY
mode Complies
Complies
No reaction recognized
TEST EQUIPMENT USED: 22, 30, 31, 32, 33, 34, 35