DOWNLOAD Harman Kardon AVR 3550 (serv.man13) Service Manual ↓ Size: 1.97 MB | Pages: 50 in PDF or view online for FREE

Model
AVR 3550 (serv.man13)
Pages
50
Size
1.97 MB
Type
PDF
Document
EMC - CB Certificate
Brand
Device
Audio
File
avr-3550-sm13.pdf
Date

Harman Kardon AVR 3550 (serv.man13) EMC - CB Certificate ▷ View online

 
IEC 60065, 6th edition : 1998
 - 
- Page 37 of 40 - 
 
 
   
 
Order No. 
200219130
 
 
 
 
 
FAULT CONDITION TESTS (continued)   
Comp. 
No 
Fault 
Test V 
Position 
Test time  Fuse No 
Current 
through 
fuse 
Mains power/temperatures/results 
C922 
S-c 
254,4 
30 min 
F902 
 
1,59 A 
Output signal off immediately. 
Input current stabilised at 0,43A. 
No component damaged. 
No hazard. 
IC92 
S-c 
254,4 
Pin 2 - 3 
30 min 
F902 
 
1,65 A 
Normal operating. 
Input current stabilised at 1,63A. 
No component damaged. 
No hazard. 
C924 
S-c 
254,4 
30 min 
F902 
 
Protection circuit operated (pr. 
relay, RY94 off) after 5 sec. 
Input current stabilised at 0,01A. 
No hazard. 
C915 
S-c 
254,4 
30 min 
F902 
F903 
F904 
F903, F904 opened immediately. 
Input current stabilised at 0,18A. 
No hazard. 
C915 
S-c 
207 
30 min 
F902 
F903 
F904 
F903, F904 opened immediately. 
Input current stabilised at 0,16A. 
No hazard. 
Q657 
S-c 
254,4 
C - E 
30 min 
F902 
F903 
F904 
Protection circuit operated (pr. 
relay, RY94 off) after 4 sec. 
F903, F904 opened. 
Q601, Q611, Q626, Q657, Q661  
shorted. 
Input current stabilised at 0,01A. 
No hazard. 
Q657 
S-c 
207 
C - E 
30 min 
F902 
F903 
F904 
Protection circuit operated (pr. 
relay, RY94 off) after 4 sec. 
F903, F904 opened. 
Input current stabilised at 0,01A. 
No hazard. 
Q657 
S-c 
254,4 
B - C 
30 min 
F902 
F903 
F904 
2,18 A 
Protection circuit operated (pr. 
relay, RY94 off) after 4 sec. 
Input current stabilised at 0,01 A. 
No component damaged. 
No hazard. 
Q621 
S-c 
254,4 
C - E 
30 min 
F902 
F903 
F904 
2,38 A 
Protection circuit operated (pr. 
relay, RY94 off) after 4 sec. 
Input current stabilised at 0,01 A. 
No component damaged. 
No hazard. 
F No = Fault Number, S-c = Short-circuit, Dis = Disconnection
 
 
IEC 60065, 6th edition : 1998
 - 
- Page 38 of 40 - 
 
 
   
 
Order No. 
200219130
 
 
 
 
 
FAULT CONDITION TESTS (continued)   
Comp. 
No 
Fault 
Test V 
Position 
Test time  Fuse No 
Current 
through 
fuse 
Mains power/temperatures/results 
Q621 
S-c 
254,4 
B - E 
30 min 
F902 
F903 
F904 
1,58 A 
Front L channel output off 
immediately. 
Input current stabilised at 1,33 A. 
No component damaged. 
No hazard. 
Q611 
S-c 
254,4 
B - C 
30 min 
F902 
F903 
F904 
1,62 A 
Normal operating. 
Input current stabilised at 1,60A. 
No component damaged. 
No hazard. 
Q611 
S-c 
254,4 
C - E 
30 min 
F902 
F903 
F904 
1,61 A 
Normal operating. 
Input current stabilised at 1,60A. 
No component damaged. 
No hazard. 
Q611 
S-c 
254,4 
B - E 
30 min 
F902 
F903 
F904 
2,70 A 
Protection circuit operated (pr. 
relay, RY94 off) after 4 sec. 
Input current stabilised at 0,01 A. 
No component damaged. 
No hazard. 
Q661 
S-c 
254,4 
C - E 
30 min 
F902 
F903 
F904 
Protection circuit operated (pr. 
relay, RY94 off) immediately. 
R656 opened. 
Q611, Q657 shorted. 
R646, R651, R656 damaged. 
Input current stabilised at 0,01A. 
No hazard. 
Q661 
S-c 
254,4 
B - C 
30 min 
F902 
F903 
F904 
1,85 A 
Protection circuit operated (pr. 
relay, RY94 off) after 4 sec. 
Input current stabilised at 0,01 A. 
No component damaged. 
No hazard. 
Q626 
S-c 
254,4 
C - E 
30 min 
F902 
F903 
F904 
1,93 A 
Protection circuit operated (pr. 
relay, RY94 off) after 4 sec. 
Input current stabilised at 0,01 A. 
No component damaged. 
No hazard. 
Q626 
S-c 
254,4 
B - E 
30 min 
F902 
F903 
F904 
1,17 A 
Front L channel output off 
immediately. 
Input current stabilised at 1,33 A. 
No component damaged. 
No hazard. 
F No = Fault Number, S-c = Short-circuit, Dis = Disconnection
 
 
IEC 60065, 6th edition : 1998
 - 
- Page 39 of 40 - 
 
 
   
 
Order No. 
200219130
 
 
 
 
 
FAULT CONDITION TESTS (continued)   
Comp. 
No 
Fault 
Test V 
Position 
Test time  Fuse No 
Current 
through 
fuse 
Mains power/temperatures/results 
D901 
S-c 
254,4 
A - C 
14 min 
F902 
0,03 A 
Pr. relay RY94 off immediately. 
Input current stabilised at 0,03A. 
Sub-transformer pr. winding heated 
up to 121K and thermal fuse opened 
after 14 min. 
Dielectric strength test OK. 
No hazard. 
C906 
S-c 
254,4 
13 min 
F902 
0,03 A 
Pr. relay RY94 off immediately. 
Input current stabilised at 0,03A. 
Sub-transformer pr. winding heated 
up to 123K and thermal fuse opened 
after 13 min. 
Dielectric strength test OK. 
No hazard. 
IC94 
S-c 
254,4 
Pin 1 - 2 
2 hr 
F902 
1,64 A 
Normal operating. 
No component damaged. 
No hazard. 
C907 
S-c 
254,4 
1 hr 
F902 
0,02 A 
Pr. relay RY94 off immediately. 
Input current stabilised at 0,02A. 
No component damaged. 
No hazard. 
C911 
S-c 
254,4 
12 min 
F902 
0,03 A 
Pr. relay RY94 off immediately. 
Input current stabilised at 0,03A. 
D902 damaged. 
Sub-transformer pr. winding heated 
up to 125K and thermal fuse opened 
after 12 min. 
Dielectric strength test OK. 
No hazard. 
Top 
cover 
opening 
Blocked 
254,4 
10 min. 
F902 
F903 
F904 
1,62 A 
Components are heated up to; 
- Main transf. winding 
: 55K   
- Main transf. core 
: 50K 
- Sub transf. pr. winding  : 42K 
- Sub transf. core 
: 36K 
- PWB near D909 
: 68K 
- C917 body 
: 26K 
- TR, Q657 body 
: 50K 
and protection circuit operated (pr. 
relay, RY94 off) after 10 min. 
Dielectric strength test OK. 
No hazard. 
F No = Fault Number, S-c = Short-circuit, Dis = Disconnection
 
 
IEC 60065, 6th edition : 1998
 - 
- Page 40 of 40 - 
 
 
   
 
Order No. 
200219130
 
 
 
 
 
FAULT CONDITION TESTS (continued)   
Comp. 
No 
Fault 
Test V 
Position 
Test time  Fuse No 
Current 
through 
fuse 
Mains power/temperatures/results 
Speaker 
terminal 
(Front) 
S-c 
254,4 
L - G 
4 sec 
F902 
F903 
F904 
Protection circuit operated (pr. 
relay, RY94 off) after 4 sec. 
Input current stabilised at 0,01A. 
No component damaged. 
No hazard. 
Pmax 
operat. 
Maximu
m non -
clipped 
output 
signal 
254,4 
4 min. 
F902 
F903 
F904 
3,41 A 
F903, F904 opened after 4 min. 
Input current stabilised at 0,18A.   
No hazard. 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
F No = Fault Number, S-c = Short-circuit, Dis = Disconnection
 
 
Page of 50
Display