Harman Kardon AVR 3550 (serv.man13) EMC - CB Certificate ▷ View online
-
IEC 60065, 6th edition : 1998
-
- Page 33 of 40 -
Order No.
200219130
LIST OF CRITICAL COMPONENTS
P
Part No
Component/
Object
Object
Manufacturer
Type / Model
Ratings /
Technical Data
Technical Data
Complies
with the
following
standard
with the
following
standard
Marks of
conformity
granted **
conformity
granted **
Main
transformer
Bobbin
material
Thermal fuse
transformer
Bobbin
material
Thermal fuse
Seoul Electronics &
Telecom Co., Ltd.
Various
Therm-O-Disc Europe.
Telecom Co., Ltd.
Various
Therm-O-Disc Europe.
KLT5W006ZE/
CLT5W006ZE
PETP or
CLT5W006ZE
PETP or
equiv
.
G4A51167C
230V, Class B
94V-0
94V-0
10A/250V, 167℃
IEC60065
clause 14.3
UL94
IEC60691
clause 14.3
UL94
IEC60691
1.)
UL
VDE
UL
VDE
T902
Sub
transformer
Bobbin
material
Thermal fuse
transformer
Bobbin
material
Thermal fuse
Seoul Electronics &
Telecom Co., Ltd.
Various
Uchihashi Estec Co.
Telecom Co., Ltd.
Various
Uchihashi Estec Co.
KLT5J033ZE /
CLT5J033ZE
PETP or
CLT5J033ZE
PETP or
equiv.
423
230V, Class E
94V-0
94V-0
0.5A/250V 130
°
C
IEC60065
clause 14.3
UL94
IEC60691
clause 14.3
UL94
IEC60691
1.)
UL
VDE
UL
VDE
For
CENELEC
c
CENELEC
c
ountries
Mains plug
with cord
with cord
Phino Electrical
Wire & Cable
Wire & Cable
PHP-211
H03VVH2-F
H03VVH2-F
10/16A/250V
6A/250V
6A/250V
IEC60884-1
S, VDE
alt.
H.R. Silvine Electronics
Inc.
Inc.
202
H03VVH2-F
H03VVH2-F
10/16A/250V
6A/250V
6A/250V
IEC60884-1
S, VDE
alt.
Volex (Asia) Pte Ltd.
M3204
H03VVH2-F
H03VVH2-F
10/16A/250V
6A/250V
6A/250V
IEC60884-1
S, VDE
alt.
Harvest Electronic
Wire.
Wire.
HE-102
H03VVH2-F
H03VVH2-F
10/16A/250V
6A/250V
6A/250V
IEC60884-1
S, VDE
For UK
Mains plug
with cord
with cord
PHINO Electronics
Co., Ltd
Co., Ltd
PHP-307F
H03VVH2-F
H03VVH2-F
13A/250V
6A/250V
6A/250V
BS1363
BS6500
BS6500
BSI
alt.
Winbo Industries
MS 323N
H03VVH2-F
H03VVH2-F
13A/250V
6A/250V
6A/250V
BS1363
BS6500
BS6500
BSI
F900,
F901
F901
Outlet fuse
alt.
alt.
alt.
alt.
Littelfuse Triad Inc.
Schurter AG.
Samjoo Enterprise.
Schurter AG.
Samjoo Enterprise.
50T, 5x20mm
FST, 5x20mm
50T, 5x20mm
FST, 5x20mm
50T, 5x20mm
T2.5A L 250V
IEC60127
S, VDE
F902
Mains fuse
alt.
alt.
alt.
alt.
Littelfuse Triad Inc.
Schurter AG.
Samjoo Enterprise.
Schurter AG.
Samjoo Enterprise.
50T, 5x20mm
FST, 5x20mm
50T, 5x20mm
FST, 5x20mm
50T, 5x20mm
T4A L 250V
IEC60127
S, VDE
F903,
F904
F904
Sec. fuse
alt.
alt.
Littelfuse Triad Inc.
Samjoo Enterprise
Samjoo Enterprise
51S, 5x20mm
51S, 5x20mm
51S, 5x20mm
SB 8A 250V
UL198G
UL
**) Marks listed under “Marks of conformity granted” indicates that Nemko has verified certifications respectively
1.) Tested as part of the Apparatus according to EN 60 065 / IEC 60065, 6.Edition : 1998
-
IEC 60065, 6th edition : 1998
-
- Page 34 of 40 -
Order No.
200219130
LIST OF CRITICAL COMPONENTS (continued)
P
Part No
Component/
Object
Object
Manufacturer
Type / Model
Ratings /
Technical Data
Technical Data
Complies
with the
following
standard
with the
following
standard
Marks of
conformity
granted **
conformity
granted **
SW1
Mains switch
POSTEC Electric Co.
SDL1P-B
5A/80A 250V
IEC 61058-1
S, VDE
RY94
Mains relay
Original Electromecha.
SDT-S-112DMR
8A/120A 250V
IEC 61058-1
IEC 60065
S
C903
X-capacitor
alt.
alt.
alt.
alt.
alt.
alt.
alt.
alt.
Pilkor Electronics.
Pilkor Electronics.
ISKRA Elect.
Okaya Electric Inc.
Yuchang Electronics.
Pilkor Electronics.
ISKRA Elect.
Okaya Electric Inc.
Yuchang Electronics.
PCX2 335M
PCX2 335
KNB1530
RE104
WBU1942
PCX2 335
KNB1530
RE104
WBU1942
0.10uF 275V
X2
X2
IEC60384-
14, 2
14, 2
nd
ed.
S, VDE
C853,
C904
C904
X-capacitor
alt.
alt.
alt.
alt.
alt.
alt.
Korea Electronics
Netron Tech.
Sam Wha Capacitor.
Murata Mfg.
Netron Tech.
Sam Wha Capacitor.
Murata Mfg.
NU
AA
SC
KH
AA
SC
KH
0.0047uF/250V
X1/Y2
X1/Y2
IEC384-14
2
2
nd
ed.
S, VDE
Mains
Socket-Outlet
Socket-Outlet
Dae Ryung Electronic
A3-04-D007
2.5A/250V
IEC 60884-1
N
PCB
Various
Various
Min 94V-1
UL 796
UL
Comments
**) Marks listed under “Marks of conformity granted” indicates that Nemko has verified certifications respectively
1.) Tested as part of the Apparatus according to EN 60 065 / IEC 60065, 6.Edition : 1998
-
IEC 60065, 6th edition : 1998
-
- Page 35 of 40 -
Order No.
200219130
FAULT CONDITION TESTS
P
Ambient temperature
26 °C
Rated voltage
230V~ 50Hz
Remarks
-
Comp.
No
No
Fault
Test V
Position
Test time Fuse No
Current
through
fuse
through
fuse
Mains power/temperatures/results
D909
S-c
254,4
AC - +
30 min
F902
F903
F904
F903
F904
-
F904 opened immediately.
Input current stabilised at 1,55A.
No hazard.
Input current stabilised at 1,55A.
No hazard.
D909
S-c
207
AC - +
30 min
F902
F903
F904
F903
F904
-
F904 opened immediately.
Input current stabilised at 1,49A.
No hazard.
Input current stabilised at 1,49A.
No hazard.
D909
S-c
254,4
AC - -
30 min
F902
F903
F904
F903
F904
-
F903 opened immediately.
Input current stabilised at 1,51A.
No hazard.
Input current stabilised at 1,51A.
No hazard.
D901
S-c
254,4
A - C
30 min
F902
1,78 A
R903 opened.
Input current stabilised at 1,61A.
No hazard.
Input current stabilised at 1,61A.
No hazard.
D904
S-c
254,4
A - C
30 min
F902
1,80 A
FL display off immediately.
R903, R904 opened.
Input current stabilised at 1,57A.
No hazard.
R903, R904 opened.
Input current stabilised at 1,57A.
No hazard.
C923
S-c
254,4
-
30 min
F902
1,86 A
FL display off immediately.
Signal output off.
R903, R904 opened.
Input current stabilised at 1,12A.
No hazard.
Signal output off.
R903, R904 opened.
Input current stabilised at 1,12A.
No hazard.
C911
S-c
254,4
-
30 min
F902
1,62 A
Normal operating.
Input current stabilised at 1,62A.
No component damaged.
No hazard.
Input current stabilised at 1,62A.
No component damaged.
No hazard.
Q901
S-c
254,4
B - E
30 min
F902
1,62 A
Normal operating.
Input current stabilised at 1,62A.
No component damaged.
No hazard.
Input current stabilised at 1,62A.
No component damaged.
No hazard.
Q901
S-c
254,4
C - E
30 min
F902
1,62 A
Normal operating.
Input current stabilised at 1,61A.
No component damaged.
No hazard.
Input current stabilised at 1,61A.
No component damaged.
No hazard.
C907
S-c
254,4
-
30 min
F902
1,79 A
FL display off immediately.
Input current stabilised at 1,63A.
R901 damaged. No hazard.
Input current stabilised at 1,63A.
R901 damaged. No hazard.
F No = Fault Number, S-c = Short-circuit, Dis = Disconnection
-
IEC 60065, 6th edition : 1998
-
- Page 36 of 40 -
Order No.
200219130
FAULT CONDITION TESTS (continued)
P
Comp.
No
No
Fault
Test V
Position
Test time Fuse No
Current
through
fuse
through
fuse
Mains power/temperatures/results
D906
S-c
254,4
A - C
30 min
F902
1,74 A
FL display off immediately.
Input current stabilised at 1,63A.
No component damaged.
No hazard.
Input current stabilised at 1,63A.
No component damaged.
No hazard.
C961
(1
(1
st
)
S-c
254,4
-
30 min
F902
1,80 A
FL display off immediately.
PWB pattern (10V dc line) opened
after 30sec, but all the special
conditions of Cl. 11.2.3 are met.
Input current stabilised at 1,58A.
No hazard.
PWB pattern (10V dc line) opened
after 30sec, but all the special
conditions of Cl. 11.2.3 are met.
Input current stabilised at 1,58A.
No hazard.
C961
(2
(2
nd
)
S-c
254,4
-
30 min
F902
1,84 A
(After repair of opened PWB pattern)
FL display off immediately.
R903, R904 opened.
Input current stabilised at 1,58A.
No hazard.
R903, R904 opened.
Input current stabilised at 1,58A.
No hazard.
IC93
S-c
254,4
Pin 1 - 3
30 min
F902
1,66 A
FL display off immediately.
Input current stabilised at 1,65A
No component damaged.
No hazard.
Input current stabilised at 1,65A
No component damaged.
No hazard.
C962
S-c
254,4
-
30 min
F902
1,64 A
FL display off immediately.
Input current stabilised at 1,62A
No component damaged.
No hazard.
Input current stabilised at 1,62A
No component damaged.
No hazard.
D903
S-c
254,4
A - C
30 min
F902
1,62 A
Normal operating.
R901 opened.
Input current stabilised at 1,62A.
No hazard.
R901 opened.
Input current stabilised at 1,62A.
No hazard.
C917
S-c
254,4
-
30 min
F902
-
FL display off immediately.
Output signal off.
R901, R902 opened.
Input current stabilised at 0,54A.
No hazard.
Output signal off.
R901, R902 opened.
Input current stabilised at 0,54A.
No hazard.
C918
S-c
254,4
-
30 min
F902
2,07 A
Protection circuit operated (pr.
relay, RY94 off) after 5 sec.
R901, R902 opened.
No hazard.
relay, RY94 off) after 5 sec.
R901, R902 opened.
No hazard.
IC91
S-c
254,4
Pin 1 - 3
30 min
F902
1,69 A
Normal operating.
Input current stabilised at 1,64A.
No component damaged.
No hazard.
Input current stabilised at 1,64A.
No component damaged.
No hazard.
F No = Fault Number, S-c = Short-circuit, Dis = Disconnection
Click on the first or last page to see other AVR 3550 (serv.man13) service manuals if exist.