Harman Kardon AVR 345 (serv.man2) EMC - CB Certificate ▷ View online
Reference No. : 54120703A Page 4
◀ Anam EMC Test Laboratory ▶
1.CLIENT INFORMATION
The EUT has been tested by request of:
* Company
: Harman Consumer Group
8500 Balboa Blvd., Northridge, CA 91329, USA
* Contact Person
: Mr. Patrick Zarrabi
* Tel.
: +1-818-895-8161
2.EQUIPMENT UNDER TEST (EUT)
2.1. Identification of the EUT
*Equipment
: AV Receiver
*Model No.
: AVR345/230
*Brand Name
: Harman/Kardon
*Serial No.
: N/A
*Manufacturer
(China)
(China)
: DongGuan LiaoBu Anam Electronics.
Xin Cheng Management Area, LiaoBu Town,
DongGuan City, Guang Dong province, China
Fax: +86-769-321 6338, Tel: +86-769-332 6888
Xin Cheng Management Area, LiaoBu Town,
DongGuan City, Guang Dong province, China
Fax: +86-769-321 6338, Tel: +86-769-332 6888
*Power Rating
: AC 230V, 50Hz 400W,
*Tuner Section
: FM 87.5 ㎒ ~ 108 ㎒ (50 ㎑ Steps)
: AM 522 ㎑ ~ 1,620 ㎑ (9 ㎑ Steps)
: AM 522 ㎑ ~ 1,620 ㎑ (9 ㎑ Steps)
*External signal
In/Out terminal
In/Out terminal
: Audio IN/OUT(CD, TAPE IN/OUT, VID3, VID2, VID1
IN/OUT, DVD, 6CH, 8CH, MULTI OUT)
: VIDEO(VID3, VID2, VID1 IN/OUT, DVD,
MONITOR OUT)
: S-VIDEO(VID3, VID2, VID1 IN/OUT, DVD,
MONITOR OUT)
: Component(INPUT 1,2,3, MONITOR OUT)
: Coaxial 1,2,3,OUT
: OPTICAL 1,2,3,OUT,
: RS232C, DMP, A-BUS
: HDMI OUT, IN1, IN2
: AC OUTLET
: CARR OUT, MULTI IN, REMOTE IN/OUT
: PREOUT(FL/FR/SL/SR/C/SW/SBL/SBR)
: VIDEO4 AUDIO L/R, VIDEO, S-VIDEO
: SPEAKER(FL/FR/SR/SL/C/SBL/SBR) ALL 8ohm
: Coaxial 1,2,3,OUT
: OPTICAL 1,2,3,OUT,
: RS232C, DMP, A-BUS
: HDMI OUT, IN1, IN2
: AC OUTLET
: CARR OUT, MULTI IN, REMOTE IN/OUT
: PREOUT(FL/FR/SL/SR/C/SW/SBL/SBR)
: VIDEO4 AUDIO L/R, VIDEO, S-VIDEO
: SPEAKER(FL/FR/SR/SL/C/SBL/SBR) ALL 8ohm
2.2. Additional Information about the EUT
The EUT consists of the following Subsystems/Modules/Parts: N/A
The test have been performed on the EUT provided with the following
modifications: None.
modifications: None.
Reference No. : 54120703A Page 5
◀ Anam EMC Test Laboratory ▶
3.TEST SPECIFICATIONS
3.1. Standards
*EN55013 (2001)&+A1(2003) :
Sound and Television broadcast receivers and Associated equipment
-Radio Disturbance characteristics - Limits and methods of measurement.
-Radio Disturbance characteristics - Limits and methods of measurement.
*EN61000-3-2
(2000):
Part 3-2: Limits- Limits for harmonic current emissions
(Equipment input current ≤16A per phase)
*EN61000-3-3 (1995 +Amd.1;2001):
Part 3-3: Limits- Limitation of voltage changes, voltage fluctuations and
flicker in public low-voltage supply systems for equipment with rated
current ≤16A.
flicker in public low-voltage supply systems for equipment with rated
current ≤16A.
3.2. Additions, deviations and exclusions from standard
No additions, deviations or exclusions have been made from standard.
3.3. Purpose of the test:
To determine whether the EUT fulfils the EMC-emission requirements of the
Standards stated in section 3.1.
3.4. Mode of operation during the test
The EUT was operated in such a way as to deliver one-eighth on the non-clipped
output power to the rated load impedance using the sinusoidal of 1 ㎑ & color-
bar.
The EUT was set to the mode of Tuner.
4.TEST SUMMARY
The results in this report apply only to sample(s) tested:
Test item
Passed
the test
Note
Mains terminal disturbance voltage
Yes
Disturbance Radiation
Yes
Disturbance Power
Yes
Harmonics Yes
Voltage Fluctuations-Flicker
Yes
The equipment does comply with the requirements.
For the measurement data, see Annex.
Reference No. : 54120703A Page 6
◀ Anam EMC Test Laboratory ▶
5. MAINS TERMINAL DISTURBANCE VOLTAGE IN THE FREQUENCY
RANGE 0.15MHz TO 30MHz
5.1. Operating environment
Temperature
: 20℃
Relative humidity : 40 %
5.2. Test set-up and procedure
The mains terminal disturbance voltage was measured with the EUT in a
Screened room. The EUT was placed on a non-metallic table by 0.8m above
the metallic grounded floor and 0.4m from the reference ground panel (RGP)
wall. The distance to other metallic surfaces was at least 0.8m.
The EUT was tested with the outer conductor of the antenna input connected
as well as not connected to the ground terminal of the AMN.
The level of the test signal was 500mV (1kHz) at coaxial RF input connector.
Amplitude measurements were performed with a quasi-peak detector and,
If required, with an average detector.
Screened room. The EUT was placed on a non-metallic table by 0.8m above
the metallic grounded floor and 0.4m from the reference ground panel (RGP)
wall. The distance to other metallic surfaces was at least 0.8m.
The EUT was tested with the outer conductor of the antenna input connected
as well as not connected to the ground terminal of the AMN.
The level of the test signal was 500mV (1kHz) at coaxial RF input connector.
Amplitude measurements were performed with a quasi-peak detector and,
If required, with an average detector.
5.3. Measurement uncertainty
Mains terminal disturbance voltage, quasi-peak detection: ±2.0dB
Mains terminal disturbance voltage, average detection : ±2.0dB
The measurement uncertainty describes the overall uncertainty of the given
measured value during the operation of the EUT in the above-mentioned way.
Reference No. : 54120703A Page 7
◀ Anam EMC Test Laboratory ▶
5.4. Test instrument
Equipment
Manufacturer
Type No.
Serial No.
Test site
Shielded room
-
-
Measurement
Receiver
Receiver
R & S
ESCI
100348
R & S
ESH3-Z5
844249/020
Artificial mains
Network EMCO 3825/2 90101718
R. C. Oscillator
Network EMCO 3825/2 90101718
R. C. Oscillator
Kenwood
AG-203A
3090241
Signal Generator
Anritsu
MG3632A
MT79870
* R & S: Rohde & Schwarz
5.5. Test protocol
Date: February 27, 2007
Grounded at the Signal GND Terminal on the Rear Enclosure.
An overview sweep performed with peak detector is included in the test
report as Annex A.
report as Annex A.
Quasi-peak (㏈㎶) Average
(㏈㎶)
Disturbance value
Disturbance value
Mode
Freq.
(㎒)
Limit
Line 1
Line 2
Limit
Line 1
Line 2
Tuner .162 65.7 44.4 44.5 55.7 16.5 15.9
12.288 60.0 23.8 28.6 50.0 23.7 28.6
24.577 60.0 26.3 27.8 50.0 26.5 28.0
24.577 60.0 26.3 27.8 50.0 26.5 28.0
Ungrounded at the Signal GND Terminal on the Rear Enclosure.
An overview sweep performed with peak detector is included in the test
report as Annex A
report as Annex A
Quasi-peak (㏈㎶) Average
(㏈㎶)
Disturbance value
Disturbance value
Mode
Freq.
(㎒)
Limit
Line 1
Line 2
Limit
Line 1
Line 2
Tuner .162 65.7 45.2 44.2 55.7 17.2 17.0
12.288 60.0 22.6 27.5 50.0 22.4 27.4
24.577 60.0 20.2 27.6 50.0 19.8 27.7
24.577 60.0 20.2 27.6 50.0 19.8 27.7
VID4 .150 66.0 49.6 49.7 56.0 23.5 25.6
24.577 60.0 25.5 30.6 50.0 25.6 30.8
The equipment does comply with the requirements.
For the measurement data, see Annex A (6 Copies).
Click on the first or last page to see other AVR 345 (serv.man2) service manuals if exist.