Harman Kardon AVR 345 (serv.man2) EMC - CB Certificate ▷ View online
Reference No. : 54120703A Page 16
◀ Anam EMC Test Laboratory ▶
9. HARMONICS
9.1. Operating environment
Temperature
: 20℃
Relative humidity : 45%
9.2. Test set-up and procedure
Harmonics of the fundamental current were measured up to 2 ㎑ using a
universal power analyzer. The measurement was carried out under steady
conditions and using averaging.
The Class of this equipment is “Class A” by clause 5 of EN61000-3-2 : 2000.
The measurement was performed with the Test software for Windows
The input signal and load conditions were set as given in clause 4.2.4 of
IEC 60065.
The input signal and load conditions were set as given in clause 4.2.4 of
IEC 60065.
9.3. Test instrumentation
Equipment
Mfr.
Type No.
Serial No.
R. C. Oscillator
Kenwood
AG-203A
3090241
Universal power analyzer Voltech
PM 3300
AK19/7742
Programmable controller
Pacific
360AMXT/UPC32
151
Magnetics module
Pacific
134310
334
9.4. Test result
The equipment does comply with the requirements.
For the measurement data, see Annex C (3 Copies).
For the measurement data, see Annex C (3 Copies).
Reference No. : 54120703A Page 17
◀ Anam EMC Test Laboratory ▶
10. VOLTAGE FLUCTUATIONS-FLICKER
10.1. Operating environment
Temperature
: 25℃
Relative humidity : 60%
10.2. Test set-up and procedure
The open circuit test voltage was the rated voltage of the EUT.
The reference impedance was a conventional impedance being used to calculate
or measure the disturbance caused by an appliance.
or measure the disturbance caused by an appliance.
The measurement was performed with the Test software for Windows
10.3. Test instrumentation
Equipment
Mfr.
Type No.
Serial No.
R. C. Oscillator
Kenwood
AG-203A
3090241
Reference impedance
Voltech
IEC Standard 555
IB16/0725
Universal power analyzer Voltech
PM 3300
AK19/7742
Programmable controller
Pacific
360AMXT/UPC32
151
Magnetics module
Pacific
134310
334
10.4. Test result
The equipment does comply with the requirements.
For the measurement data, see Annex D (2 Copies).
Reference No. : 54120703A Page 18
◀ Anam EMC Test Laboratory ▶
11. Photograph of the EUT
11.1 Front of the EUT
11.2 Rear of the Product
Reference No. : 54120703A Page 19
◀ Anam EMC Test Laboratory ▶
11.3 Inside view 1 of Product
11.3 Inside view 2 of the Product
Click on the first or last page to see other AVR 345 (serv.man2) service manuals if exist.