- Page 10 of 43 - 
 
 
 
 
 Report 
No. 
98389 
 
 
 
 Reinforced 
insulation > 0,4 mm (mm)  ............... : 
Bobbins of main and sub  
 transformer, ref. 14.3.
 
 
Thin sheet insulation (excluding non-separable 
thin sheet insulation. See 8.22) 
No thin sheet insulation
 
N/A 
 
Basic or supplementary insulation, at least two 
layers, each meeting 10.3 
 
N/A 
 
Basic or supplementary insulation, three layers 
any two of which meet 10.3 
 
N/A 
 
Reinforced insulation, two layers each of which 
meet 10.3 
 
N/A 
 
Reinforced insulation, three layers any two which 
meet 10.3 
 
N/A 
8.9 
Adequate insulation between internal hazardous 
live conductors and accessible parts 
Double insulated. 
 
Adequate insulation between internal hazardous 
live parts and conductors connected to accessible 
parts 
Single insulation but  
safely anchored. 
8.10 
Double insulation between conductors connected 
to the mains and accessible parts. 
Double insulation between internal hazardous live 
parts and conductors connected to accessible 
parts. 
Double insulated,  
tested according to 8.9  
and 10.3.
 
8.11 
Detaching of wires 
 
 
No undue reduction of creepages or clearance 
distances if wires become detached 
One end of switch 
connected wires are 
hooked-in before soldered. 
Other primary wires are 
connected with multi-contact 
housing. 
 Vibration 
test 
carried out  ..................................... : 
See 12,1,2
 
N/A 
8.12 
This clause is void 
 
— 
8.13 
Adequate fastening of windows, lenses, lamp 
covers etc. (pull test 20 N for 10 s) 
Adequately fastened.
 
8.14 
Adequate fastening of covers (pull test 50 N for 
10 s) 
Covers adequately  
fastened with screws.
 
8.15 
No risk of damage to the insulation of internal 
wiring due to hot parts or sharp edges 
Wires safely anchored  
away from parts with high  
temperature.
 
 
 
- Page 11 of 43 - 
 
 
 
 
 Report 
No. 
98389 
 
 
 
8.16 
Only special supply equipment can be used 
Not supplied by a special  
supply apparatus.
 
N/A 
8.17 
Insulated winding wire without additional 
interleaved insulation 
No such winding wire.
 
N/A 
8.18 
Endurance test as required by 8.17 
 
N/A 
8.19 
Disconnection from the mains 
See below
 
8.19.1 Disconnect 
device 
Mains plug is used as 
disconnect devices. 
 
All-pole switch or circuit breaker with >3mm 
contact separation 
No all-pole mains switch 
or circuit breaker.
 
N/A 
8.19.2 
Mains switch ON indication 
Indicator lamp or  
FL display lit-on
 
8.20 
Switch not fitted in the mains cord 
 
8.21 
Bridging components comply with clause 14 
Yes, relay across the 
capacitor is certified comp.  
See appended table, list of 
critical components.
 
8.22 
Non-separable thin sheet material 
No non-separable thin  
sheet material. 
N/A 
 
 
 
ELECTRIC SHOCK HAZARD UNDER NORMAL OPERATING CONDITIONS 
 
9.1 
Testing on the outside 
9.1.1 
For voltages >1000 V ac or >1500 V dc complies 
with clause 13.3.1 for basic insulation  
No voltages exceeding 
1000V AC or 1500V DC.
 
N/A 
9.1.1.1 
a) Open circuit voltages 
Mains input voltage > 35V,  
see below. 
— 
 
b) Touch current measured from terminal devices 
using the network in annex D  ............................. : 
See attachment, Table to 
EN/IEC 60065 7
th
 edition.
 
 
c) Discharge not exceeding 45 μC 
No part or contact of a 
terminal with stored voltage
s between 60V - 15 kV.
 
N/A 
 
d) Energy of discharge not exceeding 350 mJ 
No part or contact of  
a terminal with stored  
voltages exceeding 15kV
 
N/A 
 
 
- Page 12 of 43 - 
 
 
 
 
 Report 
No. 
98389 
 
 
 
9.1.1.2 
Test with test finger and test probe 
No access to hazardous  
live parts
 
9.1.2 
No hazardous live shafts of knobs, handles or 
levers 
No live shaft, handles or 
levers
 
N/A 
9.1.3 
Ventilation holes and other holes tested by means 
of 4 mm x 100 mm test pin 
No access for the test pin
 
9.1.4 
Terminal devices tested with 1 mm x 20 mm test 
pin (10 N); test probe D of IEC 61032 
Does not reach hazardous 
live parts
 
 
Terminal devices tested with 1 mm x 100 mm 
straight wire (1 N); test probe D of IEC 61032 
Does not reach hazardous  
live parts
 
9.1.5 
Pre-set controls tested with 2.5 mm x 100 mm test 
pin (10 N); test probe C of IEC 61032 
No preset controls
 
N/A 
9.1.6 
No shock hazard due to stored charge on 
withdrawal of the mains plug; voltage (V) after 2 s 
 ................................................................................. : 
See below
 
N/A 
 
If C is not greater than 0,1 μF no test needed 
< 0,1 uF
 
9.1.7 
a) Enclosure sufficiently resistant to external force  
 
 Test probe 11 of IEC 61032 for 10 s (50 N) 
Test with test finger result 
in no hazard
 
 
b) Test hook of fig. 4 for 10 s (20 N) 
Test with test hook results 
in no hazard.
 
 
c) 30 mm diameter test tool for 5 s (100 or 250 N) :
Tested with 100N results  
in no damage.
 
9.2 
No hazard after removing a cover by hand 
No cover removable by 
hand
 
N/A 
 
 
- Page 13 of 43 - 
 
 
 
 
 Report 
No. 
98389 
 
 
 
10 INSULATION 
REQUIREMENTS 
 
10.1 
Insulation resistance (MΩ) at least 2 MΩ min. after 
surge test for basic and 4 MΩ min. for reinforced 
insulation  ............................................................... : 
> 100 M
Ω, after surge test 
 
10.2 Humidity 
treatment 48 h or 120 h  ....................... : 
120 h (40
°C).  
No impairment
 
10.3 
Insulation resistance and dielectric strength 
between mains teminals 
See appended table 
 
Insulation Resistance and dielectric strength 
across BASIC or SUPPLEMENTARY insulation 
(Class 1) 
Class II apparatus.
 
N/A 
 
Insulation resistance and dielectric strength 
across REINFORCED insulation (Class II) 
See appended table
 
 
 
 
 
11 FAULT 
CONDITIONS 
 
11.1 
No shock hazard under fault condition 
No electric shock hazard 
under fault conditions.
 
11.2 
Heating under fault condition 
See appended table
 
 
No hazard from softening solder 
No softening of solder
 
 
Flames extinguish within 10 seconds 
No flames 
 
Soldered terminations not used  as protective 
mechanism 
No protective mechanism 
11.2.1 
Measurement of temperature rises 
See appended table
 
11.2.2 
Temperature rise of accessible parts 
See appended table
 
11.2.3 
Temperature rise of parts, other than windings, 
providing electrical insulation 
See appended table
 
 
Temperature rise of printed circuit boards (PCB) 
exceeding the limits of table 3 by max. 100 K for 
max. 5 min 
No exceeding the limits of  
Table 3.
 
 
a) Temperature rise of printed circuit boards 
(PCB) to 20.1.3, exceeding the limits of table 3 by 
not more than 100 K for an area not greater than 
2 cm² 
No area where temperature  
exceeds 100K above limits
 
N/A 
 
b) Temperature rise of printed circuit boards 
(PCB) to 20.1.3 up to 300 K for an area not greater 
than 2 cm² for a maximum of 5 min 
No area where temperature  
exceeds 300K above limits
 
N/A 