Harman Kardon AVR 260 (serv.man3) EMC - CB Certificate ▷ View online
- Page 6 of 43 -
Report
No.
98389
3 GENERAL
REQUIREMENTS
Safety class of the apparatus ............................. :
Class II apparatus
—
4
GENERAL CONDITIONS OF TESTS
4.1.4
Ventilation instructions require the use of the test
box
box
No test box required.
Tested according to
manufacturer’s instructions
Tested according to
manufacturer’s instructions
N/A
5 MARKING
Comprehensible and easily discernible
On front and rear side of
the enclosure.
the enclosure.
P
Permanent durability against water and petroleum
spirit
spirit
Tested with water / spirit
P
5.1 Identification,
maker, model ............................... :
Maker: “Harman / Kardon”
Model: “AVR 255/230.”
See copy of marking plate
Model: “AVR 255/230.”
See copy of marking plate
P
Class II symbol if applicable
Class II symbol is applied
in according to IEC 60417-
5172
in according to IEC 60417-
5172
P
Rated supply voltage and symbol ...................... :
“220V-230V” or “220V”
and AC-symbol (
~
) used.
P
Frequency if safety dependant
“50/60 Hz” or “60Hz”
P
Rated current or power consumption ............... :
390W
P
5.2 Earth
terminal
Class II apparatus.
N/A
Hazardous live terminals
No hazardous live terminals.
The output signal will rise to
37Vpeak at maximum out
power if the speaker output
load is disconnected.
No hazard.
37Vpeak at maximum out
power if the speaker output
load is disconnected.
No hazard.
P
- Page 7 of 43 -
Report
No.
98389
Supply output terminals (other than mains)
“W” and “A”
with rated
supply voltage/frequency
marked close to the
socket outlet;
socket outlet;
”SWITCHED
, 50W 0.5A
MAX”
P
5.3
Use of triangle with exclamation mark
Correct symbol applied;
printed on rear side in
connection with CAUTION
of opening. Further,
no incorrect use of this
symbol found.
printed on rear side in
connection with CAUTION
of opening. Further,
no incorrect use of this
symbol found.
P
5.4
Instructions for use
User information in the
following language: English.
See comments in
Summary of Testing.
following language: English.
See comments in
Summary of Testing.
P
5.4.1
Mains powered equipment not exposed to
dripping or splashing. Warning concerning
objects filled with liquid, etc.
dripping or splashing. Warning concerning
objects filled with liquid, etc.
The user manual includes
information about danger
concerning dripping or
splashing and objects filled
with liquids.
information about danger
concerning dripping or
splashing and objects filled
with liquids.
P
Hazardous live terminals, instructions for wiring
No hazardous live terminals
N/A
Instructions for replacing lithium battery
No lithium battery in the
equipment
equipment
N/A
Instructions for modem if fitted
No modem.
N/A
Class I earth connection warning
Class II apparatus.
N/A
Instructions for multimedia system connection
N/A
Special stability warning for fixed installation
Not for fixed installation.
N/A
Warning: battery exposure to heat
No battery.
N/A
Warning: protective film on CRT face
No CRT
N/A
5.4.2
Disconnect device: plug/coupler or all-pole mains
switch location, accessibility and markings
switch location, accessibility and markings
Plug is regarded as
disconnect device and is
readily operable.
disconnect device and is
readily operable.
P
Instructions for permanently connected
equipment
equipment
Not permanently
connected equipment
connected equipment
N/A
- Page 8 of 43 -
Report
No.
98389
6 HAZARDOUS
RADIATION
6.1
Ionizing radiation < 36 pA/kg (0,5 mR/h)
No lionizing radiation.
N/A
6.1
EN 60065
European Council Directive 96/29/Euratom of 13
May 1996 10cm from outer surface of apparatus
<1µSv/h (0,1mR/h)
May 1996 10cm from outer surface of apparatus
<1µSv/h (0,1mR/h)
N/A
6.2
Laser radiation, emission limits to IEC 60825-1 :
No laser
N/A
Emission limits under fault conditions ............. :
N/A
7
HEATING UNDER NORMAL OPERATING CONDITIONS
7.1
Temperature rises not exceeding specified values,
no operation of fuse links
no operation of fuse links
No fuse links operate during
normal operating operation.
See appended table
normal operating operation.
See appended table
P
7.1.1
Temperature rise of accessible parts
See appended table
P
7.1.2
Temperature rise of parts providing electrical
insulation
insulation
See appended table
P
7.1.3
Temperature rise of parts acting as a support or
as a mechanical barrier
as a mechanical barrier
See appended table
P
7.1.4
Temperature rise of windings
See appended table
P
7.1.5
Parts not subject to a limit under 7.1.1 to 7.1.4
See appended table
P
7.2
Softening temperature of insulating material
supporting parts conductively connected to the
mains carrying a current > 0,2 A at least 150
supporting parts conductively connected to the
mains carrying a current > 0,2 A at least 150
o
C
Approved components
according to relevant IEC
standards.
according to relevant IEC
standards.
N/A
- Page 9 of 43 -
Report
No.
98389
8
CONSTRUCTIONAL REQUIREMENTS WITH REGARD TO THE PROTECTION
AGAINST ELECTRIC SHOCK
AGAINST ELECTRIC SHOCK
8.1
Conductive parts covered by lacquer, paper,
untreated textile oxide films and beads etc.
considered to be bare
untreated textile oxide films and beads etc.
considered to be bare
Considered
P
8.2
No shock hazard when changing voltage setting
device, fuse-links or handling drawers etc.
device, fuse-links or handling drawers etc.
Operation “By hand” not
possible
possible
N/A
8.3
Insulation of hazardous live parts not provided by
hygroscopic material
hygroscopic material
No hygroscopic materials
used
used
N/A
8.4
No risk of electric shock following the removal of
a cover which can be removed by hand
a cover which can be removed by hand
No cover removable by
hand
hand
N/A
8.5
Class I equipment
Class II apparatus.
N/A
Basic insulation between hazardous live parts and
earthed accessible parts
earthed accessible parts
N/A
Resistors bridging basic insulation complying
with 14.1 a)
with 14.1 a)
N/A
8.6
Class II equipment and Class II constructions
within Class I equipment
within Class I equipment
Class II apparatus.
P
Reinforced or double insulation between
hazardous live parts and accessible parts
hazardous live parts and accessible parts
Double/Reinforced
insulation complies with
requirements specified in
clause 10 and 13.
insulation complies with
requirements specified in
clause 10 and 13.
P
Components bridging reinforced or double
insulation complying with 14.1 a) or 14.3
insulation complying with 14.1 a) or 14.3
The apparatus has
isolating transformers.
isolating transformers.
P
Basic and supplementary insulation each being
bridged by a capacitor complying with 14.1 a)
bridged by a capacitor complying with 14.1 a)
No such capacitors.
N/A
Reinforced or double insulation being bridged
with 2 capacitors in series complying with
14.2.1 a)
with 2 capacitors in series complying with
14.2.1 a)
No such capacitors.
N/A
Reinforced or double insulation being bridged
with a single capacitor complying with 14.2.1 b)
with a single capacitor complying with 14.2.1 b)
No such capacitors.
N/A
Basic insulation bridged by components
complying with 14.3.4.3
complying with 14.3.4.3
No such components.
N/A
8.7
This clause is void
—
8.8
Basic or supplementary insulation > 0,4 mm (mm)
................................................................................. :
................................................................................. :
N/A