- Page 29 of 43 -
Report
No.
98389
20.2 Fire
enclosure
N/A
20.2.1
Potential ignition sources with open circuit
voltage > 4 kV (peak) a.c. or d.c. contained in a fire
enclosure to V-1
voltage > 4 kV (peak) a.c. or d.c. contained in a fire
enclosure to V-1
No voltages exceeding
4kV, no fire enclosure
requirement
4kV, no fire enclosure
requirement
N/A
20.2.2
Internal fire enclosures with openings not
exceeding 1 mm in width and with openings for
wires completely filled
exceeding 1 mm in width and with openings for
wires completely filled
No internal fire enclosure.
N/A
20.2.3
Requirements of 20.2.1 and 20.2.2 met by an
internal fire enclosure
internal fire enclosure
No internal fire enclosure.
N/A
- Page 30 of 43 -
Report
No.
98389
A
APPENDIX A, ADDITIONAL REQUIREMENTS FOR APPARATUS WITH
PROTECTION AGAINST SPLASHING WATER
PROTECTION AGAINST SPLASHING WATER
A.5.1
j) Marked with IPX4 (IEC 60529), 5.4.1 a) does
not apply
not apply
Not intended for outdoor use
N/A
A.10.2.1
Enclosure provides protection against
splashing water
splashing water
N/A
A.10.2.2
Humidity treatment carried out for 7 days
See clause above
N/A
B
APPENDIX B, APPARATUS TO BE CONNECTED TO THE
TELECOMMUNICATION NETWORKS
TELECOMMUNICATION NETWORKS
Complies with IEC 62151 clause 1
No TNV circuits
N/A
Complies with IEC 62151 clause 2
N/A
Complies with IEC 62151 clause 3 but with
3.5.4 modified to 2.4.10 of this standard
3.5.4 modified to 2.4.10 of this standard
N/A
Complies with IEC 62151 clause 4 but with
4.1.2, 4.1.3 and 4.2.1.2 modified in accordance
with annex B of this standard
4.1.2, 4.1.3 and 4.2.1.2 modified in accordance
with annex B of this standard
N/A
Complies with IEC 62151 cause 5 but with 5.3.1
modified in accordance with annex B of this
standard
modified in accordance with annex B of this
standard
N/A
Complies with IEC 62151 clause 6
N/A
Complies with IEC 62151 clause 7
N/A
Complies with IEC 62151 annex A, B and C
N/A
- Page 31 of 43 -
Report
No.
98389
IEC 62151 clause 4.1.1:
Add after the first paragraph:
NOTE- In Finland, Norway and Sweden, class I
equipment which is intended for connection to
the building installation via a non-industrial
plug or a non-industrial appliance coupler, or
both and in addition is intended for connection
to other equipment or a network shall, if safety
relies on connection to protective earth or if
surge suppressors are connected between the
network terminals and ACCESSIBLE parts,
have a marking stating that the equipment
must be connected to an earthed mains
socket-outlet.
The marking text in the applicable countries
shall be as follow:
In Finland,
"Laite on liitettävä
suojamaadoituskoskettimilla va
rustettuunpistorasiaan”
In Norway,
"Apparatet må tilkoples jordet stikkontakt"
In Sweden,
"Apparaten skall anslutas till jordat uttag”
Add after the first paragraph:
NOTE- In Finland, Norway and Sweden, class I
equipment which is intended for connection to
the building installation via a non-industrial
plug or a non-industrial appliance coupler, or
both and in addition is intended for connection
to other equipment or a network shall, if safety
relies on connection to protective earth or if
surge suppressors are connected between the
network terminals and ACCESSIBLE parts,
have a marking stating that the equipment
must be connected to an earthed mains
socket-outlet.
The marking text in the applicable countries
shall be as follow:
In Finland,
"Laite on liitettävä
suojamaadoituskoskettimilla va
rustettuunpistorasiaan”
In Norway,
"Apparatet må tilkoples jordet stikkontakt"
In Sweden,
"Apparaten skall anslutas till jordat uttag”
Class II apparatus
N/A
L
APPENDIX L, ADDITIONAL REQUIREMENTS FOR ELECTRONIC FLASH
APPARATUS FOR PHOTOGRAPHIC PURPOSES.
APPARATUS FOR PHOTOGRAPHIC PURPOSES.
N/A
L5.4
Marking and Instructions
N/A
L9.1.1
Terminals to connection to synchroniser not
HAZARDOUS LIVE
HAZARDOUS LIVE
N/A
L7.1.5 &
L11.2.6
Lithium batteries meet permissible temp rise in
Table 3 , unless comply with 6.3.2 of IEC
60086-4
Table 3 , unless comply with 6.3.2 of IEC
60086-4
N/A
L14.6.6
Mains switch characteristics appropriate to its
function under normal conditions
function under normal conditions
N/A
No electronic flash
apparatus
apparatus
N/A
-
Page 32 of 43 -
Report
No.
98389
7.1
TABLE: temperature rise measurements
P
Power consumption in the OFF/Stand-by
In OFF/Stand-by position,
the power consumption is
less than 0,6W.
the power consumption is
less than 0,6W.
—
Position of the functional switch (W) ................ :
—
—
Operating conditions
Standby mode at 50Hz;
Un (V)
In (A)
Pn (W)
Pout (W)
230 0,004 0,6 —
220 0,003 0,5 —
Standby mode at 60Hz;
Un (V)
In (A)
Pn (W)
Pout (W)
230 0,003 0,5 —
220 0,003 0,5 —
Measured at maximum non-clipped output at 50Hz;
Un (V)
In (A)
Pn (W)
Pout (W)
253
5,10
1069
2 x 80,0 W
(F)
1 x 80,6 W
(C)
2 x 83,2 W
(S)
2 x 80,0 W
(S/B)
Measured at maximum non-clipped output at 60Hz;
253
5,02
1054
2 x 80,0 W
(F)
1 x 80,6 W
(C)
2 x 83,2 W
(S)
2 x 80,0 W
(S/B)
Tested condition: 1kHz input signal, connected 8 ohm loads for F, C, S, SB channels