Report
No.
98389
Test item particulars .................................................. :
A/V Surround Receiver
Classification of installation and use ...................... :
Class II apparatus
Supply connection .................................................... :
By non-detachable power supply cord to mains socket.
Possible test case verdicts:
- test case does not apply to the test object ........... :
N/A
- test object does meet the requirement .................. :
Pass (P)
- test object does not meet the requirement ........... :
Fail (F)
Testing:
Date of receipt of test items………………………….:
December 22, 2007
Date(s) of performance of tests ................................ :
December 22, 2007 - January 22, 2008
General remarks:
The test results presented in this report relate only to the object tested.
This report shall not be reproduced, except in full, without the written approval of the Issuing testing
laboratory.
This report shall not be reproduced, except in full, without the written approval of the Issuing testing
laboratory.
"(see Enclosure #)" refers to additional information appended to the report.
"(see appended table)" refers to a table appended to the report.
Throughout this report, a point (coma) is used as the decimal separator.
"(see appended table)" refers to a table appended to the report.
Throughout this report, a point (coma) is used as the decimal separator.
List of test equipment must be kept on file and available for review.
General product information:
The sample(s) tested complies with the requirements of IEC 60065: 2001 + A1: 2005 / EN 60065: 2002
+ A1: 2006. Compliance with European Special National Conditions, Annex ZB, and A – Deviations,
Annex ZC, and tested according to national requirements for the following countries;
All CENELEC Countries listed in EN60065: 2002, Singapore and Korea, but Korean deviations are not
included in this report (not announced yet).
+ A1: 2006. Compliance with European Special National Conditions, Annex ZB, and A – Deviations,
Annex ZC, and tested according to national requirements for the following countries;
All CENELEC Countries listed in EN60065: 2002, Singapore and Korea, but Korean deviations are not
included in this report (not announced yet).
- Page 6 of 43 -
Report
No.
98389
3 GENERAL
REQUIREMENTS
Safety class of the apparatus ............................. :
Class II apparatus
—
4
GENERAL CONDITIONS OF TESTS
4.1.4
Ventilation instructions require the use of the test
box
box
No test box required.
Tested according to
manufacturer’s instructions
Tested according to
manufacturer’s instructions
N/A
5 MARKING
Comprehensible and easily discernible
On front and rear side of
the enclosure.
the enclosure.
P
Permanent durability against water and petroleum
spirit
spirit
Tested with water / spirit
P
5.1 Identification,
maker, model ............................... :
Maker: “Harman / Kardon”
Model: “AVR 255/230.”
See copy of marking plate
Model: “AVR 255/230.”
See copy of marking plate
P
Class II symbol if applicable
Class II symbol is applied
in according to IEC 60417-
5172
in according to IEC 60417-
5172
P
Rated supply voltage and symbol ...................... :
“220V-230V” or “220V”
and AC-symbol (
~
) used.
P
Frequency if safety dependant
“50/60 Hz” or “60Hz”
P
Rated current or power consumption ............... :
390W
P
5.2 Earth
terminal
Class II apparatus.
N/A
Hazardous live terminals
No hazardous live terminals.
The output signal will rise to
37Vpeak at maximum out
power if the speaker output
load is disconnected.
No hazard.
37Vpeak at maximum out
power if the speaker output
load is disconnected.
No hazard.
P
- Page 7 of 43 -
Report
No.
98389
Supply output terminals (other than mains)
“W” and “A”
with rated
supply voltage/frequency
marked close to the
socket outlet;
socket outlet;
”SWITCHED
, 50W 0.5A
MAX”
P
5.3
Use of triangle with exclamation mark
Correct symbol applied;
printed on rear side in
connection with CAUTION
of opening. Further,
no incorrect use of this
symbol found.
printed on rear side in
connection with CAUTION
of opening. Further,
no incorrect use of this
symbol found.
P
5.4
Instructions for use
User information in the
following language: English.
See comments in
Summary of Testing.
following language: English.
See comments in
Summary of Testing.
P
5.4.1
Mains powered equipment not exposed to
dripping or splashing. Warning concerning
objects filled with liquid, etc.
dripping or splashing. Warning concerning
objects filled with liquid, etc.
The user manual includes
information about danger
concerning dripping or
splashing and objects filled
with liquids.
information about danger
concerning dripping or
splashing and objects filled
with liquids.
P
Hazardous live terminals, instructions for wiring
No hazardous live terminals
N/A
Instructions for replacing lithium battery
No lithium battery in the
equipment
equipment
N/A
Instructions for modem if fitted
No modem.
N/A
Class I earth connection warning
Class II apparatus.
N/A
Instructions for multimedia system connection
N/A
Special stability warning for fixed installation
Not for fixed installation.
N/A
Warning: battery exposure to heat
No battery.
N/A
Warning: protective film on CRT face
No CRT
N/A
5.4.2
Disconnect device: plug/coupler or all-pole mains
switch location, accessibility and markings
switch location, accessibility and markings
Plug is regarded as
disconnect device and is
readily operable.
disconnect device and is
readily operable.
P
Instructions for permanently connected
equipment
equipment
Not permanently
connected equipment
connected equipment
N/A
- Page 8 of 43 -
Report
No.
98389
6 HAZARDOUS
RADIATION
6.1
Ionizing radiation < 36 pA/kg (0,5 mR/h)
No lionizing radiation.
N/A
6.1
EN 60065
European Council Directive 96/29/Euratom of 13
May 1996 10cm from outer surface of apparatus
<1µSv/h (0,1mR/h)
May 1996 10cm from outer surface of apparatus
<1µSv/h (0,1mR/h)
N/A
6.2
Laser radiation, emission limits to IEC 60825-1 :
No laser
N/A
Emission limits under fault conditions ............. :
N/A
7
HEATING UNDER NORMAL OPERATING CONDITIONS
7.1
Temperature rises not exceeding specified values,
no operation of fuse links
no operation of fuse links
No fuse links operate during
normal operating operation.
See appended table
normal operating operation.
See appended table
P
7.1.1
Temperature rise of accessible parts
See appended table
P
7.1.2
Temperature rise of parts providing electrical
insulation
insulation
See appended table
P
7.1.3
Temperature rise of parts acting as a support or
as a mechanical barrier
as a mechanical barrier
See appended table
P
7.1.4
Temperature rise of windings
See appended table
P
7.1.5
Parts not subject to a limit under 7.1.1 to 7.1.4
See appended table
P
7.2
Softening temperature of insulating material
supporting parts conductively connected to the
mains carrying a current > 0,2 A at least 150
supporting parts conductively connected to the
mains carrying a current > 0,2 A at least 150
o
C
Approved components
according to relevant IEC
standards.
according to relevant IEC
standards.
N/A