Harman Kardon AVR 240 (serv.man13) EMC - CB Certificate ▷ View online
- Page 3 of 7 -
www.nemko.com
Report No. 65654
11
FAULT CONDITIONS TESTS-continued
P
Comp.
No.
No.
Location Fault
Test V
Test
time
time
Fuse
No.
No.
Current
through
fuse
through
fuse
Temperature/Results
D991
AC - +
S-c
253
10 min
F907
F903
F904
F903
F904
- Normal
operating.
Input current stabilised at 1,76A.
F904 opened. No hazard.
(Repeated test three times with the
same result)
F904 opened. No hazard.
(Repeated test three times with the
same result)
C902 - S-c 207 10
min
F907
F903
F904
F903
F904
-
Front, Surr Back channels signal
output off immediately.
Input current stabilised at 0,85 A.
F903, F904 opened.
No hazard.
(Repeated test three times with the
same result)
output off immediately.
Input current stabilised at 0,85 A.
F903, F904 opened.
No hazard.
(Repeated test three times with the
same result)
C902 - S-c 253 10
min
F907
F903
F904
F903
F904
-
Front, Surr Back channels signal
output off immediately.
Input current stabilised at 0,89 A.
F903, F904 opened.
No hazard.
(Repeated test three times with the
same result)
output off immediately.
Input current stabilised at 0,89 A.
F903, F904 opened.
No hazard.
(Repeated test three times with the
same result)
D992
AC - +
S-c
207
10 min
F907
F905
F906
F905
F906
- Normal
operating.
Input current stabilised at 1,70A.
F906 opened.
No hazard.
F906 opened.
No hazard.
D992
AC - +
S-c
253
10 min
F907
F905
F906
F905
F906
- Normal
operating.
Input current stabilised at 1,78A.
F906 opened.
No hazard.
F906 opened.
No hazard.
C915 - S-c 253 10
min
F907
F905
F906
F905
F906
-
Center, Surround channels signal
output off immediately.
Input current stabilised at 1,21A.
F905, F906 opened.
No hazard.
output off immediately.
Input current stabilised at 1,21A.
F905, F906 opened.
No hazard.
Q803
C - E
S-c
207
10 min
F907
F905
F906
F905
F906
-
Unit shut down immediately.
Input current stabilised at 0,01A.
F905, F906 opened.
No hazard.
Input current stabilised at 0,01A.
F905, F906 opened.
No hazard.
Q803
C - E
S-c
253
10 min
F907
F905
F906
F905
F906
-
Unit shut down immediately.
Input current stabilised at 0,01A.
F905, F906 opened.
Q804 shorted.
No hazard.
Input current stabilised at 0,01A.
F905, F906 opened.
Q804 shorted.
No hazard.
F No = Fault Number, S-c = Short-circuit, Dis = Disconnection
- Page 4 of 7 -
www.nemko.com
Report No. 65654
11
FAULT CONDITIONS TESTS-continued
P
Comp.
No.
No.
Location Fault
Test V
Test
time
time
Fuse
No.
No.
Current
through
fuse
through
fuse
Temperature/Results
Q803
B - C
S-c
253
10 min
F907
F905
F906
F905
F906
-
Unit shut down immediately.
Input current stabilised at 0,01A.
No component damaged.
No hazard.
Input current stabilised at 0,01A.
No component damaged.
No hazard.
C807 - S-c 253 20
min
F907
F905
F906
F905
F906
2,16 A
Surround L channel signal output
distorted immediately.
Input current stabilised at 1,61A.
R821 opened.
No hazard.
distorted immediately.
Input current stabilised at 1,61A.
R821 opened.
No hazard.
Q804
C - E
S-c
253
10 min
F907
F905
F906
F905
F906
-
Unit shut down immediately.
Input current stabilised at 0,01A.
F905, F906 opened.
Q903, Q804 shorted.
No hazard.
Input current stabilised at 0,01A.
F905, F906 opened.
Q903, Q804 shorted.
No hazard.
Q804
B - C
S-c
253
10 min
F907
F905
F906
F905
F906
-
Unit shut down immediately.
Input current stabilised at 0,01A.
No component damaged.
No hazard.
Input current stabilised at 0,01A.
No component damaged.
No hazard.
C813 - S-c 253 20
min
F907
F905
F906
F905
F906
1,56 A
Surround L channel signal output
off immediately.
Input current stabilised at 1,56A.
No component damaged.
No hazard.
off immediately.
Input current stabilised at 1,56A.
No component damaged.
No hazard.
D962
A - C
S-c
253
15 min
-
1,78 A
Sub transformer primary winding
heated-up to 109K thermal fuse
opened after 15 min.
Dielectric strength test O.K.
No hazard.
heated-up to 109K thermal fuse
opened after 15 min.
Dielectric strength test O.K.
No hazard.
C906
-
S-c
253
14 min
-
< 0,03
A
A
Mains relay off immediately.
Sub transformer primary winding
heated-up to 111K thermal fuse
opened after 14 min.
Dielectric strength test O.K.
No hazard.
Sub transformer primary winding
heated-up to 111K thermal fuse
opened after 14 min.
Dielectric strength test O.K.
No hazard.
C907
-
S-c
253
1 hr
-
< 0,02
A
A
Mains relay off immediately.
Sub transformer primary winding
heated-up to 80K and stabilised.
Dielectric strength test O.K.
No hazard.
Sub transformer primary winding
heated-up to 80K and stabilised.
Dielectric strength test O.K.
No hazard.
F No = Fault Number, S-c = Short-circuit, Dis = Disconnection
- Page 5 of 7 -
www.nemko.com
Report No. 65654
11
FAULT CONDITIONS TESTS-continued
P
Comp.
No.
No.
Location Fault
Test V
Test
time
time
Fuse
No.
No.
Current
through
fuse
through
fuse
Temperature/Results
Fan
(Heat-sink
installed)
installed)
- Locked
253
5
hr
F907,
F903,
F904,
F905,
F906
F903,
F904,
F905,
F906
1,79 A
Normal operated.
The components are heated up to:
- Main transf. pr. winding : 74K
- Main transformer core : 58K
- Sub transf. pr. winding : 58K
- Sub transformer core
The components are heated up to:
- Main transf. pr. winding : 74K
- Main transformer core : 58K
- Sub transf. pr. winding : 58K
- Sub transformer core
: 48K
- D991 body
: 58K
- PWB near D991
: 62K
- Q803 body
: 58K
- PWB near Q804
: 56K
- Main Heat-sink
: 65K
and stabilised.
Dielectric strength test OK.
No hazard.
Dielectric strength test OK.
No hazard.
Speaker
Terminal
Terminal
Surr.
(
(
L - ch.)
S-c 253 10
min
F907
F905
F906
F905
F906
-
Unit shut down immediately.
Input current stabilised at 0,01A.
No component damaged.
No hazard.
Input current stabilised at 0,01A.
No component damaged.
No hazard.
Top cover
opening
opening
- Blocked
253
5
hr
F907,
F903,
F904,
F905,
F906
F903,
F904,
F905,
F906
1,79 A
The components are heated up to:
- Main transf. pr. winding : 69K
- Main transformer core : 57K
- Sub transf. pr. winding : 56K
- Sub transformer core
- Main transf. pr. winding : 69K
- Main transformer core : 57K
- Sub transf. pr. winding : 56K
- Sub transformer core
: 51K
- D991 body
: 70K
- PWB near D991
: 73K
- Q803 body
: 75K
- PWB near Q804
: 76K
- Main Heat-sink
: 77K
and Unit shut down after 13 min.
Input current stabilised at 0,013A.
Dielectric strength test OK.
No hazard.
Input current stabilised at 0,013A.
Dielectric strength test OK.
No hazard.
Pmax
operating
- Maximu
m non-
clipped
output
signal
clipped
output
signal
253 39
min
F907,
F903,
F904,
F905,
F906
F903,
F904,
F905,
F906
3,80 A
The components are heated up to:
- Main transf. pr. Winding : 144K
- Main transformer core : 82K
- D992 body
- Main transf. pr. Winding : 144K
- Main transformer core : 82K
- D992 body
: 81K
- PWB near D992
: 87K
- Q803 body
: 55K
- PWB near Q804
: 52K
and main transf. thermal fuse
opened after 39 min.
Dielectric strength test OK.
No hazard.
opened after 39 min.
Dielectric strength test OK.
No hazard.
F No = Fault Number, S-c = Short-circuit, Dis = Disconnection
- Page 6 of 7 -
www.nemko.com
Report No. 65654
13.3 - 13.4
Clearances and Creepage distances
P
Type of
Insulation
Position/
Location
Location
Position/
Location
Location
Working
Voltage
Clearance
13.3.2
Creepage dist.
13.4
Comm.
1 2
Up
Urms
Req.
Measu.
Req.
Measu.
Basic Live Neutral 326V
230V
2,0mm
4,0mm 2,5mm
4,0mm
1)
Reinforce Primary
Chassis
326V 230V 4,0mm 8,0mm 5,0mm >
8,0mm 2)
Reinforce Primary
C708
*)
379V 268V 4,0mm 7,8mm 5,6mm >
7,8mm
3)
Reinforce Primary
Chassis
326V 230V 4,0mm 7,3mm 5,0mm >
7,3mm 4)
Reinforce Primary
Chassis
326V 230V 4,0mm 6,8mm 5,0mm 6,8mm 5)
Reinforce Primary
Secondary 379V 268V 4,0mm 6,0mm 5,6mm 6,0mm 6)
*) 2N force applied
Note: U in Volt, Clearances/Creepage Distances in mm, Comm. = Comment
Comments:
1) Measured on PCB before mains fuse (F907).
2) Measured between primary pcb trace for socket-outlet and near metal chassis (back cover).
3) Measured between socket outlet terminal and near C708 secondary E. capacitor.
4) Measured between main pcb primary solder pin and metal bottom chassis.
5) Measured on main pcb from pri. pcb trace to metal chassis connected sec. pcb trace.
6) Measured on main pcb from pri. pcb trace to near secondary pcb trace.
2) Measured between primary pcb trace for socket-outlet and near metal chassis (back cover).
3) Measured between socket outlet terminal and near C708 secondary E. capacitor.
4) Measured between main pcb primary solder pin and metal bottom chassis.
5) Measured on main pcb from pri. pcb trace to metal chassis connected sec. pcb trace.
6) Measured on main pcb from pri. pcb trace to near secondary pcb trace.
Click on the first or last page to see other AVR 240 (serv.man13) service manuals if exist.