Harman Kardon AVR 240 (serv.man13) EMC - CB Certificate ▷ View online
- Page 8 of 33 -
www.nemko.com
Report No. 65654
IEC/EN 60065
Clause
Requirement – Test
Result - Remark
Verdict
8.7
Basic insulation between parts at 35 V to 71 V
(peak) a.c. or 60 V to 120 V d.c. and accessible
parts
(peak) a.c. or 60 V to 120 V d.c. and accessible
parts
No parts at 35V to 71V (peak)
a.c. or 60V to 120V d.c.
a.c. or 60V to 120V d.c.
N
Reinforced or double insulation between circuits
operating at voltages between 35 V and 71 V
(peak) a.c. or between 60 V and 120 V d.c. and
hazardous live parts at higher voltage
operating at voltages between 35 V and 71 V
(peak) a.c. or between 60 V and 120 V d.c. and
hazardous live parts at higher voltage
No parts at 35-71V(peak) a.c. or
60-120V d.c.
60-120V d.c.
N
Separation by Class II isolating transformer
Isolating transformer according to
14.3.2. (Class II)
14.3.2. (Class II)
P
Separation by Class I transformer
N
Separation by earthed conductive part
N
8.8
Basic or supplementary insulation > 0,4 mm (mm) :
N
Reinforced
insulation > 0,4 mm (mm) .................... :
Transformer bobbin,
See appended table and
attachment, Table to
EN/IEC 60065 7
See appended table and
attachment, Table to
EN/IEC 60065 7
th
edition
P
Thin sheet insulation
No thin sheet insulation
N
Basic or supplementary insulation, at least two
layers, each meeting 10.3
layers, each meeting 10.3
N
Basic or supplementary insulation, three layers any
two of which meet 10.3
two of which meet 10.3
N
Reinforced insulation, two layers each of which
meet 10.3
meet 10.3
N
Reinforced insulation, three layers any two which
meet 10.3
meet 10.3
N
8.9
Adequate insulation between internal hazardous
live conductors and accessible parts
live conductors and accessible parts
Double insulated
P
Adequate insulation between internal hazardous
live parts and conductors connected to accessible
parts
live parts and conductors connected to accessible
parts
Single insulation but safely
anchored
anchored
P
8.10
Double insulation between conductors connected
to the mains and accessible parts
to the mains and accessible parts
Double insulated, tested
according to 8.9. and 10.3.
according to 8.9. and 10.3.
P
8.11
Detaching of wires
P
No undue reduction of creepages or clearance
distances if wires become detached
distances if wires become detached
Primary wires are connected
with multi-contact-housing.
with multi-contact-housing.
P
Vibration
test carried out ........................................ :
See 12.1.2
N
TRF No: IEC/EN 60065F
- Page 9 of 33 -
www.nemko.com
Report No. 65654
IEC/EN 60065
Clause
Requirement – Test
Result - Remark
Verdict
8.12
Adequate cross-sectional area of internal wiring to
mains socket-outlets
mains socket-outlets
Protective fuse (T2.5A/250V)
with 0,82 mm
with 0,82 mm
2
wiring
P
8.13
Adequate fastening of windows, lenses, lamp
covers etc. (pull test 20 N for 10 s)
covers etc. (pull test 20 N for 10 s)
Adequately fastened.
P
8.14
Adequate fastening of covers (pull test 50 N for
10 s)
10 s)
Covers adequately fastened
with screws.
with screws.
P
8.15
No risk of damage to the insulation of internal
wiring due to hot parts or sharp edges
wiring due to hot parts or sharp edges
Wires safely anchored away
from parts with high
temperature.
from parts with high
temperature.
P
8.16
Only special supply equipment can be used
Not supplied by a special
supply apparatus.
supply apparatus.
N
8.17
Insulated winding wire without additional
interleaved insulation
interleaved insulation
No such components
N
8.18
Endurance test as required by 8.17
N
8.19
Disconnection from the mains
See below
P
8.19.1 Disconnect
device
Mains plug is used as
disconnect devices.
disconnect devices.
P
All-pole switch or circuit breaker with >3mm
contact separation
contact separation
No all-pole switch
N
8.19.2
Mains switch ON indication
Indicator lamp or FL display
lit-on
lit-on
P
8.20
Switch not fitted in the mains cord
P
8.21
Bridging components comply with clause 14
Yes, switch and relay across the
capacitors are Certified compo.
see appended table, list of
critical components.
capacitors are Certified compo.
see appended table, list of
critical components.
P
TRF No: IEC/EN 60065F
- Page 10 of 33 -
www.nemko.com
Report No. 65654
IEC/EN 60065
Clause
Requirement – Test
Result - Remark
Verdict
9
ELECTRIC SHOCK HAZARD UNDER NORMAL OPERATING CONDITIONS
9.1
Testing on the outside
P
9.1.1
For voltages >1000 V ac or >1500 V dc complies
with clause 13.3.1 for basic insulation
with clause 13.3.1 for basic insulation
No voltages >1000 V ac or
>1500 V dc
>1500 V dc
N
9.1.1.1
Touch current measured from terminal devices
using the network in annex D ................................. :
using the network in annex D ................................. :
See attachment, Table to
EN/IEC 60065 7
EN/IEC 60065 7
th
edition
P
Discharge not exceeding 45 µC
No part or contact of a
terminal with stored voltages
between 60V - 15kV
terminal with stored voltages
between 60V - 15kV
N
Energy of discharge not exceeding 350 mJ
No part or contact of a
terminal with stored voltages
exceeding 15kV
terminal with stored voltages
exceeding 15kV
N
9.1.1.2
Test with test finger and test probe
No access to hazardous live
parts
parts
P
9.1.2
No hazardous live shafts of knobs, handles or
levers
levers
No live shafts, handles or
levers
levers
N
9.1.3
Ventilation holes tested by means of
4 mm x 100 mm test pin
4 mm x 100 mm test pin
No access for the test pin.
P
9.1.4
Terminal devices tested with 1 mm x 20 mm test
pin (10 N); test probe D of IEC 61032
pin (10 N); test probe D of IEC 61032
Does not reach hazardous live
parts
parts
P
Terminal devices tested with 1 mm x 100 mm
straight wire (1 N); test probe D of IEC 61032
straight wire (1 N); test probe D of IEC 61032
Does not reach hazardous live
parts
parts
P
9.1.5
Pre-set controls tested with 2.5 mm x 100 mm test
pin (10 N); test probe C of IEC 61032
pin (10 N); test probe C of IEC 61032
No pre-set controls
N
9.1.6
No shock hazard due to stored charge on
withdrawal of the mains plug; voltage (V) after 2 s :
withdrawal of the mains plug; voltage (V) after 2 s :
Measured voltage after 2 sec:
Max. 1 V (peak).
Max. 1 V (peak).
P
If C is not greater than 0,1 µF no test needed
N
9.1.7
Enclosure sufficiently resistant to external force
P
Test probe 11 of IEC 61032 for 10 s (50 N)
Test with test finger results in
no hazard.
no hazard.
P
Test hook of fig. 4 for 10 s (20 N)
Test with test hook results in
no hazard.
no hazard.
P
30 mm diameter test tool for 5 s (100 or 250 N) .... :
Tested with 100N results in
no damage.
no damage.
P
9.2
No hazard after removing a cover by hand
No cover removable by hand
N
TRF No: IEC/EN 60065F
- Page 11 of 33 -
www.nemko.com
Report No. 65654
IEC/EN 60065
Clause
Requirement – Test
Result - Remark
Verdict
10 INSULATION
REQUIREMENTS
10.1
Insulation resistance (MΩ) at least 2 MΩ min. after
surge test for basic and 4 MΩ min. for reinforced
insulation ................................................................. :
surge test for basic and 4 MΩ min. for reinforced
insulation ................................................................. :
> 100 MΩ
P
10.2 Humidity
treatment 48 h or 120 h ........................... :
120 h (40°C). No impairment
P
10.3
Insulation resistance and dielectric strength
(see appended table)
P
11 FAULT
CONDITIONS
11.1
No shock hazard under fault condition
No electric shock hazard under
fault conditions.
fault conditions.
P
11.2
Heating under fault condition
P
No hazard from softening solder
No solder soften.
P
11.2.1
Measurement of temperature rises
See appended table and
attachment, Table to
EN/IEC 60065 7
attachment, Table to
EN/IEC 60065 7
th
edition
P
11.2.2
Temperature rise of accessible parts
See appended table and
attachment, Table to
EN/IEC 60065 7
attachment, Table to
EN/IEC 60065 7
th
edition
P
11.2.3
Temperature rise of parts, other than windings,
providing electrical insulation
providing electrical insulation
See appended table and
attachment, Table to
EN/IEC 60065 7
attachment, Table to
EN/IEC 60065 7
th
edition
P
Temperature rise of printed circuit boards (PCB)
exceeding the limits of table 3 by max. 100 K for
max. 5 min
exceeding the limits of table 3 by max. 100 K for
max. 5 min
No area where temperature
exceeds 100K above limits
exceeds 100K above limits
N
a) Temperature rise of printed circuit boards (PCB)
to 20.1.3, exceeding the limits of table 3 by not
more than 100 K for an area not greater than 2 cm²
to 20.1.3, exceeding the limits of table 3 by not
more than 100 K for an area not greater than 2 cm²
N
b) Temperature rise of printed circuit boards (PCB)
to 20.1.3 up to 300 K for an area not greater than
2 cm² for a maximum of 5 min
to 20.1.3 up to 300 K for an area not greater than
2 cm² for a maximum of 5 min
N
Meets all the special conditions if conductors on
printed circuit boards are interrupted
printed circuit boards are interrupted
No conductors are
interrupted/peeled/loosened
during fault conditions
interrupted/peeled/loosened
during fault conditions
N
Class I protective earthing maintained
Class II equipment
N
11.2.4
Temperature rise of parts acting as a support or
mechanical barrier
mechanical barrier
Temperature rises are within
the limits.
the limits.
P
TRF No: IEC/EN 60065F