Test Report
No.:
DR50120306G
5. IMMUNITY
5.1 List of Test and Measurement
Equipment and Type
Serial No.
Manufacturer
Next Cal.
Signal Generator (SMY01)
DE24241
R&S
2004.01
RF Power Meter(NRVD)
DE30994
R&S
2004.01
Function Generator(33120A)
US3602592
EMC Automation
2004.01
System Interface(SI300)
010401
EMC Automation
N/A
Switch Controller(RSM-2)
010101
EMC Automation
N/A
Amplifier 80~100MHz(100W1000M1)
20213
Amplifier Research
2003.11
Amplifier 10kHz ~250MHz(75A250M1)
24270
Amplifier Research
2003.11
Amplifier 10kHz~220MHz(AR1000L)
29370
Amplifier Research
N/A
Field Probe 10kHz ~ 1GHz(FP4000)
23376
Amplifier Research
N/A
Field Probe 10kHz ~ 1GHz(HI4422)
101389
Holaday Inc.
N/A
Antenna 80~1000MHz(LPD-80)
98023
EMC Automation
N/A
Antenna 25~150MHz(HLP2515)
120900
EMC Automation
N/A
CDN (801-M1-16A)
9832
FCC
2004.01
single power Mains(801-M2-16A)
9863
FCC
2004.01
Two power Mains801-M3-16A)
98119
FCC
2004.01
Three Power Mains801-M5-50A)
2026
FCC
2004.01
Five power Mains(S9)
9865
FCC
2004.01
Singnal Lines, 9 Pins(S15)
9866
FCC
2004.01
Signal Lines, 15 Pins(S25)
9867
FCC
2004.01
Signal Lines, 25 Pins (36S)
9868
FCC
2004.01
Signal Lines, 36 Pins(801-150-50-C)
98161,98162
FCC
2004.01
Impedance Matching Unit(DN)
2055
FCC
2004.01
Balanced with Shorting Adapters(801-T8)
2030
FCC
2004.01
Unbalanced , Unshielded Line
CDN with Shorting Adapter (801-AF8)
2027 FCC
2004.01
Coaxial Line CDN with Shorting Adapters(801-C-N-50)
435 FCC
2004.01
EM Injection Clamp(F2031-32mm)
241
FCC
N/A
Clamp On Injection probeF-120-9A)
605
FCC
N/A
Clamp On Current Probe(F-33-1)
N/A
N/A
N/A
#683-3,Yubang-Dong, Yongin-Si,Kyunggi-Do,Korea,449-080
DIGITAL EMC CO., LTD.
Page 8 of 19
Test Report
No.:
DR50120306G
5.2 Electrostatic discharge
RESULT :
Pass
5.2.1 Measurement Procedure
The immunity against electrostatic discharge was tested in accordance with
EN55020:1994+A11:1996 +A12,A13,A14:1999. A ground reference plane was located on
the floor, and connected to earth via a low impedance connection. The return cable of the ESD
generator was connected to the reference plane. In case of a table top equipment, EUT was
placed on the reference plane on 80cm of insulating support. And a vertical coupling plane
(VCP) of 0.5*0.5m was located 10cm from the EUT’s sides. The VCP was connected to the
reference plane via a cable with a 470㏀(2EA) resistor. The test was made by applying contact
EN55020:1994+A11:1996 +A12,A13,A14:1999. A ground reference plane was located on
the floor, and connected to earth via a low impedance connection. The return cable of the ESD
generator was connected to the reference plane. In case of a table top equipment, EUT was
placed on the reference plane on 80cm of insulating support. And a vertical coupling plane
(VCP) of 0.5*0.5m was located 10cm from the EUT’s sides. The VCP was connected to the
reference plane via a cable with a 470㏀(2EA) resistor. The test was made by applying contact
and air discharges to the EUT itself, and contact discharges to the VCP/HCP. When applying the
discharges to the VCP the tip of the generator was located at the middle edge of the VCP. The
VCP was located 10cm from each side of the EUT. Contact discharges of ±4kV were applied to
various points of the EUT at conductive surfaces, and to the VCP. Air discharges of ±8kV were
discharges to the VCP the tip of the generator was located at the middle edge of the VCP. The
VCP was located 10cm from each side of the EUT. Contact discharges of ±4kV were applied to
various points of the EUT at conductive surfaces, and to the VCP. Air discharges of ±8kV were
applied to various points of the EUT at non-conductive surfaces.
Severity level
: 2 (Contact Discharge)
3 (Air Discharge)
Test voltages
: ±4.0㎸ (Contact Discharge)
±
8.0㎸ (Air Discharge)
EUT Type
: Unground equipment
Number of
Contact
discharges
Number of
Air
discharges
:
>total 200 discharges(100 each at negative and positive)
> 10 discharges
Test Method
: The charge on the EUT shall be removed prior to each
applied ESD pulse.
Performance criterion
: B
5.2.2 List of Test and Measurement Instruments
Electrostatic discharge
Name of
Instrument
Model No
Serial No
Manufacturer
Next Cal.
Date
BEST EMC
BEST EMCV2.7 200122-043SC
SCHAFFNER
2003.09
ESD GUN
BEST-ESD
1072
SCHAFFNER
2003.09
PC
emachines/AC 50035 045 00056 COMPUTOWN
N/A
#683-3,Yubang-Dong, Yongin-Si,Kyunggi-Do,Korea,449-080
DIGITAL EMC CO., LTD.
Page 9 of 19
Test Report
No.:
DR50120306G
5.2.3
ESD TEST POINT AND RESULT
1) Test Data:
June 05, 2003
Temperature: 25 ℃
Temperature: 25 ℃
Humidity: 56 %
Barometric: 988 mbar
Barometric: 988 mbar
2) Uncertainty (95%,Confidence) : ± 5%
3) Point and Result
No. Position
Kind of Discharge Result Remarks
①
Enclosure(front)
Air
PASS
No disturbance of function
②
Cable
Air
PASS
No disturbance of function
③
LED Air PASS
During the test,
I heard something noise.
I heard something noise.
After testing, It works well.
④
Enclosure
(left,right,top,rear)
(left,right,top,rear)
Contact
PASS
No disturbance of function
⑤
Port
Contact
PASS
No disturbance of function
⑥
Screw
Contact
PASS
No disturbance of function
⑦
HCP / VCP
Contact
PASS
No disturbance of function
Table 1 : ESD, Positive / Negative Polarity
#683-3,Yubang-Dong, Yongin-Si,Kyunggi-Do,Korea,449-080
DIGITAL EMC CO., LTD.
Page 10 of 19
Test Report
No.:
DR50120306G
5.3 Radiated radio-frequency electromagnetic field
RESULT : Pass
5.3.1 Measurement Procedure
The immunity against radio-frequency electromagnetic fields was tested in accordance to
EN55020:1994+A11:1996+A12,A13,A14:1999. The test set-up was make according to
EN61000-4-3: 1996+A1: 1998+A2:2001 in semi-anechoic chamber. The EUT has bees
placed in center of a wooden turntable. The height of this table was 0.8m. The field strength
was monitored by an isotropic sensor during the complete test.
The isotropic sensor was located beside the equipment. The antenna has been orientated for
both horizontal and vertical polarization. The distance between antenna the equipment under
testing was at least 3m. The tests have been performed with the antenna facing each of the
four side of the EUT.
EN55020:1994+A11:1996+A12,A13,A14:1999. The test set-up was make according to
EN61000-4-3: 1996+A1: 1998+A2:2001 in semi-anechoic chamber. The EUT has bees
placed in center of a wooden turntable. The height of this table was 0.8m. The field strength
was monitored by an isotropic sensor during the complete test.
The isotropic sensor was located beside the equipment. The antenna has been orientated for
both horizontal and vertical polarization. The distance between antenna the equipment under
testing was at least 3m. The tests have been performed with the antenna facing each of the
four side of the EUT.
Radio-frequency electromagnetic field. Keyed carrier.
Severity level
: 2
Field strength
: 3V/m
Frequency range
: 900㎒ ±5㎒
Duty cycle
: 50%
Rep. frequency
: 200 Hz
Performance criterion
: A