Harman Kardon AVR 235 (serv.man2) EMC - CB Certificate ▷ View online

       
DIGITAL EMC CO., LTD.      
Page 7 of 19 
Test Report   
                                                        No.: 
DR50120306G
 
 
 
5. IMMUNITY 
 
5.1 List of Test and Measurement   
Equipment and Type 
Serial No. 
Manufacturer 
Next Cal. 
Signal Generator (SMY01) 
DE24241 
R&S 
2004.01 
RF Power Meter(NRVD) 
DE30994 
R&S 
2004.01 
Function Generator(33120A) 
US3602592 
EMC Automation 
2004.01 
System Interface(SI300) 
010401 
EMC Automation 
N/A 
Switch Controller(RSM-2) 
010101 
EMC Automation 
N/A 
Amplifier 80~100MHz(100W1000M1) 
20213 
Amplifier Research 
2003.11 
Amplifier 10kHz ~250MHz(75A250M1) 
24270 
Amplifier Research 
2003.11 
  Amplifier  10kHz~220MHz(AR1000L) 
29370 
Amplifier Research 
N/A 
Field Probe 10kHz ~ 1GHz(FP4000) 
23376 
Amplifier Research 
N/A 
Field Probe 10kHz ~ 1GHz(HI4422) 
101389 
Holaday Inc. 
N/A 
Antenna 80~1000MHz(LPD-80) 
98023 
EMC Automation 
N/A 
Antenna 25~150MHz(HLP2515) 
120900 
EMC Automation 
N/A 
CDN (801-M1-16A) 
9832 
FCC 
2004.01 
single power Mains(801-M2-16A) 
9863 
FCC 
2004.01 
Two power Mains801-M3-16A) 
98119 
FCC 
2004.01 
Three Power Mains801-M5-50A) 
2026 
FCC 
2004.01 
Five power Mains(S9) 
9865 
FCC 
2004.01 
Singnal Lines, 9 Pins(S15) 
9866 
FCC 
2004.01 
Signal Lines, 15 Pins(S25) 
9867 
FCC 
2004.01 
Signal Lines, 25 Pins (36S) 
9868 
FCC 
2004.01 
Signal Lines, 36 Pins(801-150-50-C) 
98161,98162 
FCC 
2004.01 
Impedance Matching Unit(DN) 
2055 
FCC 
2004.01 
Balanced with Shorting Adapters(801-T8) 
2030 
FCC 
2004.01 
Unbalanced , Unshielded Line   
CDN with Shorting Adapter (801-AF8)
 
2027 FCC 
2004.01 
Coaxial Line CDN with Shorting Adapters(801-C-N-50) 
435 FCC 
2004.01 
EM Injection Clamp(F2031-32mm) 
241 
FCC 
N/A 
Clamp On Injection probeF-120-9A) 
605 
FCC 
N/A 
Clamp On Current Probe(F-33-1) 
N/A 
N/A 
N/A 
#683-3,Yubang-Dong, Yongin-Si,Kyunggi-Do,Korea,449-080
 
       
DIGITAL EMC CO., LTD.      
Page 8 of 19 
Test Report   
                                                        No.: 
DR50120306G
 
 
 
5.2  Electrostatic discharge 
 
RESULT :
                                                                                                              Pass 
 
5.2.1 Measurement Procedure
 
 
The immunity against electrostatic discharge was tested in accordance with 
EN55020:1994+A11:1996 +A12,A13,A14:1999. A ground reference plane was located on 
the floor, and connected to earth via a low impedance connection. The return cable of the ESD 
generator was connected to the reference plane. In case of  a table top equipment, EUT was 
placed on the reference plane on 80cm of insulating support. And a vertical coupling plane 
(VCP) of 0.5*0.5m was located 10cm from the EUT’s sides. The VCP was connected to the 
reference plane via a cable with a 470㏀(2EA) resistor. The test was made by applying contact 
and air discharges to the EUT itself, and contact discharges to the VCP/HCP. When applying the 
discharges to the VCP the tip of the generator was located at the middle edge of the VCP. The 
VCP was located 10cm from each side of the EUT. Contact discharges of ±4kV were applied to 
various points of the EUT at conductive surfaces, and to the VCP. Air discharges of ±8kV were 
applied to various points of the EUT at non-conductive surfaces. 
 
Severity level 
: 2 (Contact Discharge) 
3 (Air Discharge) 
Test voltages 
: ±4.0㎸ (Contact Discharge) 
±
8.0㎸ (Air Discharge) 
EUT Type 
: Unground equipment 
Number of 
Contact
 discharges 
Number of 
Air 
discharges 
:
>total 200 discharges(100 each at negative and positive) 
> 10 discharges 
Test Method 
: The charge on the EUT shall be removed prior to each 
applied ESD pulse. 
Performance criterion 
: B 
 
5.2.2 List of Test and Measurement Instruments 
 
Electrostatic discharge 
Name of 
Instrument 
Model No 
Serial No 
Manufacturer 
Next Cal. 
Date 
BEST EMC 
BEST EMCV2.7 200122-043SC 
SCHAFFNER 
2003.09 
ESD GUN 
BEST-ESD 
1072 
SCHAFFNER 
2003.09 
PC 
emachines/AC  50035 045 00056  COMPUTOWN 
N/A 
 
#683-3,Yubang-Dong, Yongin-Si,Kyunggi-Do,Korea,449-080
 
       
DIGITAL EMC CO., LTD.      
Page 9 of 19 
Test Report   
                                                        No.: 
DR50120306G
 
 
 
5.2.3 
ESD TEST POINT AND RESULT 
       
1) Test Data:   
June 05, 2003 
Temperature:   25 ℃ 
Humidity:            56    %   
Barometric:    988 mbar 
 
 
2) Uncertainty (95%,Confidence) :  ±  5% 
 
 
3) Point and Result 
No.  Position 
Kind of Discharge Result  Remarks 
 
Enclosure(front) 
Air 
PASS 
No disturbance of function 
 
Cable 
Air 
PASS 
No disturbance of function 
 
LED Air PASS 
During the test,   
I heard something noise. 
After testing, It works well. 
 
Enclosure 
(left,right,top,rear) 
Contact 
PASS 
No disturbance of function 
 
Port 
Contact 
PASS 
No disturbance of function 
 
Screw 
Contact 
PASS 
No disturbance of function 
 
HCP / VCP 
Contact 
PASS 
No disturbance of function 
Table 1 : ESD, Positive / Negative Polarity 
 
#683-3,Yubang-Dong, Yongin-Si,Kyunggi-Do,Korea,449-080
 
       
DIGITAL EMC CO., LTD.      
Page 10 of 19 
Test Report   
                                                        No.: 
DR50120306G
 
 
 
5.3    Radiated radio-frequency electromagnetic field 
 
RESULT :                                                                                                              Pass 
 
5.3.1 Measurement Procedure 
The immunity against radio-frequency electromagnetic  fields was tested in accordance to 
EN55020:1994+A11:1996+A12,A13,A14:1999.  The test set-up was make according to 
EN61000-4-3: 1996+A1: 1998+A2:2001 in semi-anechoic chamber. The EUT has bees 
placed in center of a wooden turntable. The height of this table was 0.8m. The field strength 
was monitored by an isotropic sensor during the complete test. 
The isotropic sensor was located beside the equipment. The antenna has been orientated for 
both horizontal and vertical polarization. The distance between antenna the equipment under 
testing was at least 3m. The tests have been performed with the antenna facing each of the 
four side of the EUT. 
 
Radio-frequency electromagnetic field. Keyed carrier. 
 
Severity level 
: 2 
Field strength 
: 3V/m 
Frequency range 
: 900㎒  ±5㎒ 
Duty cycle 
: 50% 
Rep. frequency 
: 200 Hz 
Performance criterion 
: A 
 
#683-3,Yubang-Dong, Yongin-Si,Kyunggi-Do,Korea,449-080
 