Harman Kardon AVR 235 (serv.man2) EMC - CB Certificate ▷ View online

       
DIGITAL EMC CO., LTD.      
Page 11 of 19 
Test Report   
                                                        No.: 
DR50120306G
 
 
5.3.2 List of Test and Measurement Instruments 
Radiated radio-frequency electromagnetic field 
Name of 
Instrument 
Type Serial 
No 
Manufacturer 
Next Cal. 
Date 
Control computer 
Pentium 750MHz 
N/A 
SAMSUNG 
Software TEMTO-RS  Ver.4.3en 
TSJ 
Electric Field Sensor 
(~5KHz,~800V/m) 
HI-6005 107823 
Holaday 
2004.01 
Signal 
Generator(3.3GHz) 
SML03 
100647 
Rohde &y Schwarz 
2004.03 
Power Meter 
NRVD 
100403 
Rohde &y Schwarz 
2004.03 
RF Switch Matrix 
(~12GHz,500W) 
RFM-S3A2CIL 2075 
TSJ 
2004.05 
Antenna(75M~1.5G
Hz,1kW) 
VULP9118 754 
Schwarzbeck  2004.01 
Horn Antenna 
(0.8G~5GHz) 
BBHA9120A 322 
Schwarzbeck  2004.03 
RF Power Amplifier 
(~1GHz,250W) 
CMC250 FO44-0620 
IFI 
2004.04 
RF Power Amplifier 
(1-3GHz,25W) 
5055R 1007 
Ophir 
RF  2004.04 
 
5.3.3  TEST RESULT 
 
1) Test Data:   
June 09, 2003 
Temperature:   28 ℃ 
Humidity:            59    %   
Barometric:    990 mbar 
 
2) Uncertainty (95%,Confidence level, k=2.28) :  ±1.6dB 
 
3)  Result 
Result 
Position 
Horizontal Vertical 
Remark 
Front Side 
PASS 
PASS 
Equipment operated as intended. 
No disturbance of function 
Right Side 
PASS 
PASS 
Equipment operated as intended. 
No disturbance of function 
Left Side 
PASS 
PASS 
Equipment operated as intended. 
No disturbance of function 
Back Side 
PASS 
PASS 
Equipment operated as intended. 
No disturbance of function 
Table 2 : Radiated radio-frequency electromagnetic field
 
#683-3,Yubang-Dong, Yongin-Si,Kyunggi-Do,Korea,449-080
 
       
DIGITAL EMC CO., LTD.      
Page 12 of 19 
Test Report   
                                                        No.: 
DR50120306G
 
 
 
5.4 Electrical fast transient / burst 
 
RESULT :                                                                                                              Pass 
 
5.4.1 Measurement Procedure 
 
The immunity against fast transients was tested in accordance to EN55020:1994 +A11:1996 
+ A12,A13,A14:1999.
 on all lines which length may exceed 3m according to the 
manufacturers specification.  Test set-up with capacitive clamp and fast transient noise 
generator was according to EN61000-4-4: 1995+A1:2001. 
The EUT has been placed on a wooden table 0.8m above the reference ground plane. 
The reference ground plane exceeded the projected geometry of the EUT and the capacitive 
clamp by more than 20cm. The clamp has placed directly on the reference ground plane.   
The un-used signal connector of the clamp has been terminated with a 50Ω resistor. 
The distance between the EUT and all other conductive structures. Except the ground plane 
beneath the EUT was more than 0.5m. The distance between clamp and EUT was about 30cm. 
 
 
Severity level 
:  2 (AC Power port) 
Test voltage 
:  0.5, 1 (kV) 
Polarity : 
Negative/ 
positive 
Repetition  frequency 
:  5㎑ 
Performance criterion 
:  B 
 
5.4.2 List of Test and Measurement Instruments 
 
Electrical fast transient / burst 
Name of 
Instrument 
Model No 
Serial No 
Manufacturer 
Next Cal. 
Date 
BEST EMC 
BEST EMCV2.7 200122-043SC 
SCHAFFNER 
2003.09 
PERSONAL 
COMPUTER 
Emachines/AC 
50035 045 00056 
COMPUTOWN 
N/A 
EFT Clamp 
CDN8014 
17332 
SCHAFFNER 
N/A 
 
#683-3,Yubang-Dong, Yongin-Si,Kyunggi-Do,Korea,449-080
 
       
DIGITAL EMC CO., LTD.      
Page 13 of 19 
Test Report   
                                                        No.: 
DR50120306G
 
 
 
5.4.3 TEST RESULT 
 
1) Test Data:   
June 05, 2003 
Temperature:   25 ℃ 
Humidity:            56    %   
Barometric:    988 mbar 
 
 
2) Uncertainty (95%,Confidence) :  ±10% 
 
3) Result (AC Power Port) 
 
Line Result 
Remarks 
L1 
500V     PASS 
1KV            PASS 
Equipment operated as intended. 
No disturbance of function 
L2 
500V     PASS 
1KV            PASS   
Equipment operated as intended. 
No disturbance of function 
L1-L2 
500V     PASS 
1KV            PASS 
During the test, I heard something noise. 
After testing, It works well. 
Table 3 : AC Power lines, Positive/Negative Polarity 
 
 
 
#683-3,Yubang-Dong, Yongin-Si,Kyunggi-Do,Korea,449-080
 
       
DIGITAL EMC CO., LTD.      
Page 14 of 19 
Test Report   
                                                        No.: 
DR50120306G
 
 
 
APPENDIX 1        --- TEST SETUP PHOTOGRAPH --- 
 
 
 
 