Harman Kardon AVR 230 (serv.man12) EMC - CB Certificate ▷ View online
-
IEC 60065, 6th edition : 1998
-
- Page 32 of 37 -
Order
No.
14399
LIST OF CRITICAL COMPONENTS
P
Part No
Component/
Object
Object
Manufacturer
Type / Model
Ratings /
Technical Data
Technical Data
Complies
with the
following
standard
with the
following
standard
Marks of
conformity
granted **
conformity
granted **
For
CENELEC
Countries
CENELEC
Countries
Mains plug
with cord
with cord
Kenic Electric Mfg.
KE-21
H03VVH2-F
H03VVH2-F
2.5A/250V
6A/250V
6A/250V
IEC60884-1
VDE
alt.
Phino Electric Co.
PHP-205
H03VVH2-F
H03VVH2-F
2.5A/250V
6A/250V
6A/250V
IEC60884-1
VDE
alt.
Kuk Je Tong Shin
KKJ-1004A
H03VVH2-F
H03VVH2-F
2.5A/250V
6A/250V
6A/250V
IEC60884-1
VDE
alt.
Volex (Asia) Pte.
Ltd.
Ltd.
M4206
H03VVH2-F
H03VVH2-F
2.5A/250V
6A/250V
6A/250V
IEC60884-1
VDE
alt.
HWAJIN KDK Co., Ltd
KKP-419C
H03VVH2-F
H03VVH2-F
2.5A/250V
6A/250V
6A/250V
IEC60884-1
VDE
alt.
Kenic Electric Mfg.
KE-32
H03VVH2-F
H03VVH2-F
2.5A/250V
6A/250V
6A/250V
IEC60884-1
VDE
For U.K.
Mains plug
with cord
with cord
PHINO Electronics
Co., Ltd
Co., Ltd
PHP-307F
H03VVH2-F
H03VVH2-F
13A/250V
6A/250V
6A/250V
BS1363
BS6500
BS6500
BSI
alt.
Volex (Asia) Pte Ltd.
MP5004A
H03VVH2-F
H03VVH2-F
13A/250V
6A/250V
6A/250V
BS1363
BS6500
BS6500
BSI
alt.
Winbo Industries
MS 323N
H03VVH2-F
H03VVH2-F
13A/250V
6A/250V
6A/250V
BS1363
BS6500
BS6500
BSI
alt. Luen
Tai
(IP’S)
Elect.
Kenic Electric Mfg.
9518
H05VVH2-F
H05VVH2-F
13A/250V
6A/250V
6A/250V
BS1363
BS6500
BS6500
BSI
Main
transformer
Bobbin Mtl.
alt.
alt.
Thermal fuse
transformer
Bobbin Mtl.
alt.
alt.
Thermal fuse
Seoul Electronics &
Telecom Co., Ltd.
EI DUPONT.
SAMYANG CO LTD.
WINTECH Polymer.
Therm-O-Disc.
Telecom Co., Ltd.
EI DUPONT.
SAMYANG CO LTD.
WINTECH Polymer.
Therm-O-Disc.
KLT5W010ZE/
CLT5W010ZE
FR530
2550GN30
CN9030
CLT5W010ZE
FR530
2550GN30
CN9030
G4A51167C
230V, Class E
V-0, 155
V-0, 155
°
C.
V-0, 130
°
C.
V-0, 155
°
C
10A/250V, 167
°C
IEC60065
clause 14.3
UL94
UL94
UL94
IEC60691
clause 14.3
UL94
UL94
UL94
IEC60691
1.)
UL,
UL,
E69578
UL,
E116425
UL,
E213445
VDE
Sub
transformer
Bobbin Mtl.
alt.
alt.
Thermal fuse
transformer
Bobbin Mtl.
alt.
alt.
Thermal fuse
Seoul Electronics &
Telecom Co., Ltd.
EI DUPONT.
SAMYANG CO LTD.
WINTECH Polymer.
Uchihashi Estec Co.
Telecom Co., Ltd.
EI DUPONT.
SAMYANG CO LTD.
WINTECH Polymer.
Uchihashi Estec Co.
KLT5J033ZE /
CLT5J033ZE
FR530
2550GN30
CN9030
CLT5J033ZE
FR530
2550GN30
CN9030
423
230V, Class E
V-0, 155
V-0, 155
°
C.
V-0, 130
°
C.
V-0, 155
°
C
0.5A/250V 130
°C
IEC60065
clause 14.3
UL94
UL94
UL94
IEC60691
clause 14.3
UL94
UL94
UL94
IEC60691
1.)
UL,
UL,
E69578
UL,
E116425
UL,
E213445
VDE
**) Marks listed under “Marks of conformity granted” indicates that Nemko has verified certifications respectively
1.) Tested as part of the Apparatus according to EN 60 065 / IEC 60065, 6.Edition : 1998
-
IEC 60065, 6th edition : 1998
-
- Page 33 of 37 -
Order
No.
14399
LIST OF CRITICAL COMPONENTS (continued)
P
Part No
Component/
Object
Object
Manufacturer
Type / Model
Ratings /
Technical Data
Technical Data
Complies
with the
following
standard
with the
following
standard
Marks of
conformity
granted **
conformity
granted **
SW1 Mains
switch
alt.
NAMAE Electronics.
POSTEC Electric.
POSTEC Electric.
JPP-1197
SDL1P-B
SDL1P-B
5A/80A 250V
IEC60065
IEC61058-1
VDE
RY94
Mains relay
Tyco Electronics EC.
K.K.
K.K.
SDT-S-112DMR
8A/120A 250V
IEC60065
IEC61058-1
IEC61058-1
SEMKO
F901, F902
Outlet fuse
alt.
alt.
alt.
alt.
alt.
alt.
Littelfuse B.V.
Littelfuse Triad.
Bel Fuse.
Save Fusetech.
Littelfuse Triad.
Bel Fuse.
Save Fusetech.
0663
LT-5
MRT
SR-5
LT-5
MRT
SR-5
T2.5A 250V
IEC60127
VDE
VDE
VDE
VDE
VDE
VDE
VDE
F903, F904
F905, F906
F905, F906
Sec fuse
alt.
alt.
alt.
alt.
alt.
alt.
alt.
alt.
Littelfuse B.V.
Littelfuse Ltd.
Littelfuse Ltd.
ORISEL Co., Ltd.
Suzhou
Littelfuse OVS
Littelfuse Triad Inc.
218
06.3
218
06.3
50T
618
50T
618
50T
T6.3A L 250V
IEC60127
VDE
VDE
VDE
VDE
VDE
VDE
VDE
VDE
VDE
F907 Mains
fuse
alt.
alt.
alt.
alt.
alt.
alt.
alt.
Littelfuse B.V.
Littelfuse Ltd.
Littelfuse Ltd.
ORISEL Co., Ltd.
Suzhou
Littelfuse OVS
Littelfuse Triad Inc.
218
004
218
004
50T
618
50T
618
50T
T4A L 250V
IEC60127
VDE
VDE
VDE
VDE
VDE
VDE
VDE
VDE
VDE
C124 X-capacitor
alt.
alt.
alt.
alt.
alt.
alt.
alt.
Pilkor Electronics.
Pilkor Electronics.
Pilkor Electronics.
ISKRA Kondenzatorji d.d
.
Okaya Electric Industries
.
Yuchang
Electronics.
Electronics.
PCX2 335M
PCX2 335
KNB1530
RE104
WBU1942
PCX2 335
KNB1530
RE104
WBU1942
0.10uF 275V
X2
X2
IEC60384-14,
2
2
nd
ed.
FIMKO
SEMKO
VDE
FIMKO
FIMKO
SEMKO
VDE
FIMKO
FIMKO
C853
(switch across)
C904
(relay across)
X-capacitor
alt.
alt.
alt.
alt.
alt.
alt.
alt.
alt.
Du San Industrial.
Netron Tech.
Sam Wha Capacitor.
Murata Mfg.
Jyh Chung Elect.
Netron Tech.
Sam Wha Capacitor.
Murata Mfg.
Jyh Chung Elect.
NU
AA
SC
KH
JY
AA
SC
KH
JY
0.0047uF/250V,
X1.
X1.
IEC60384-14,
2
2
nd
ed.
FIMKO
FIMKO
FIMKO
FIMKO
FIMKO
FIMKO
FIMKO
FIMKO
FIMKO
OL91 Mains
Socket-outlet
Dae Ryung
Electronics.
Electronics.
A3-04-D007 2.5A/250V IEC60884-1
NEMKO
PCB
base
material
Various
Various
Min 94V-1
UL 796
UL
**) Marks listed under “Marks of conformity granted” indicates that Nemko has verified certifications respectively
1.) Tested as part of the Apparatus according to EN 60 065 / IEC 60065, 6.Edition : 1998
-
IEC 60065, 6th edition : 1998
-
- Page 34 of 37 -
Order
No.
14399
FAULT CONDITION TESTS
P
Ambient temperature
25,5 °C
Rated voltage
230V~ 50Hz
Remarks
-
Comp.
No
No
Fault Test
V
Short
current
current
Test time
Fuse No
Current
through
fuse
through
fuse
Mains power/temperatures/results
D104
S-c
254,4
A - C
30 min
F907
1,76 A
Normal operating.
Input current stabilised at 1,62A.
R106
Input current stabilised at 1,62A.
R106
opened.
No hazard.
C122
S-c
254,4
-
30 min
F907
1,96 A
FL display off immediately.
Input current stabilised at 1,63A.
Q104, R101 damaged.
No hazard.
Input current stabilised at 1,63A.
Q104, R101 damaged.
No hazard.
Q104
S-c
254,4
C - E
30 min
F907
1,64 A
Normal operating.
Input current stabilised at 1,62A.
No component damaged.
No hazard.
Input current stabilised at 1,62A.
No component damaged.
No hazard.
C120
S-c
254,4
-
30 min
F907
1,63 A
Normal operating.
Input current stabilised at 1,62A.
No component damaged.
No hazard.
Input current stabilised at 1,62A.
No component damaged.
No hazard.
C119
S-c
254,4
-
30 min
F907
1,85 A
FL display off immediately.
Input current stabilised at 1,62A.
R101 opened.
No hazard.
Input current stabilised at 1,62A.
R101 opened.
No hazard.
C117
S-c
254,4
-
20 min
F907
1,63 A
Normal operating.
Input current stabilised at 1,62A.
No component damaged.
No hazard.
Input current stabilised at 1,62A.
No component damaged.
No hazard.
D991
S-c
207
AC - +
10 min
F907
F903
F904
F903
F904
- Normal
operating.
Input current stabilised at 1,50A.
F904 opened.
No hazard.
F904 opened.
No hazard.
D991
S-c
254,4
AC - +
10 min
F907
F903
F904
F903
F904
- Normal
operating.
Input current stabilised at 1,57A.
F904 opened.
No hazard.
F904 opened.
No hazard.
D992
S-c
207
AC - +
10 min
F907
F905
F906
F905
F906
- Normal
operating.
Input current stabilised at 1,51A.
F906 opened.
No hazard.
F906 opened.
No hazard.
F No = Fault Number, S-c = Short-circuit, Dis = Disconnection
-
IEC 60065, 6th edition : 1998
-
- Page 35 of 37 -
Order
No.
14399
FAULT CONDITION TESTS (continued)
P
Comp.
No
No
Fault Test
V
Short
current
current
Test time
Fuse No
Current
through
fuse
through
fuse
Mains power/temperatures/results
D992
S-c
254,4
AC - +
10 min
F907
F905
F906
F905
F906
- Normal
operating.
Input current stabilised at 1,58A.
F906 opened.
No hazard.
F906 opened.
No hazard.
C902 S-c
207 -
10
min
F907
F905
F906
F905
F906
-
Rear, Center channels signal output
off immediately.
Input current stabilised at 0,93A.
F905, F906 opened.
No hazard.
off immediately.
Input current stabilised at 0,93A.
F905, F906 opened.
No hazard.
C902 S-c
254,4 -
10
min
F907
F905
F906
F905
F906
-
Rear, Center channels signal output
off immediately.
Input current stabilised at 0,90A.
F905, F906 opened.
No hazard.
off immediately.
Input current stabilised at 0,90A.
F905, F906 opened.
No hazard.
Q803
S-c
254,4
C - E
10 min
F907
F905
F906
F905
F906
-
Unit shut down immediately.
Input current stabilised at 0,01A.
F905, F906 opened.
Q804 shorted.
No hazard.
Input current stabilised at 0,01A.
F905, F906 opened.
Q804 shorted.
No hazard.
Q803
S-c
254,4
B - C
10 min
F907
F905
F906
F905
F906
-
Unit shut down immediately.
Input current stabilised at 0,01A.
No component damaged.
No hazard.
Input current stabilised at 0,01A.
No component damaged.
No hazard.
Q804
S-c
254,4
C - E
10 min
F907
F905
F906
F905
F906
-
Unit shut down immediately.
Input current stabilised at 0,01A.
F905, F906 opened.
Q903, Q803 shorted.
No hazard.
Input current stabilised at 0,01A.
F905, F906 opened.
Q903, Q803 shorted.
No hazard.
Q804
S-c
254,4
B - C
10 min
F907
F905
F906
F905
F906
-
Unit shut down immediately.
Input current stabilised at 0,01A.
No component damaged.
No hazard.
Input current stabilised at 0,01A.
No component damaged.
No hazard.
C813 S-c
254,4 -
20
min
F907
F905
F906
F905
F906
1,49 A
Surround L channel signal output
off immediately.
Input current stabilised at 1,44A.
No component damaged.
No hazard.
off immediately.
Input current stabilised at 1,44A.
No component damaged.
No hazard.
C928
S-c
254,4
-
20 min
F907
1,99 A
FL display off immediately.
Input current stabilised at 1,61A.
R106, R107 opened.
No hazard.
Input current stabilised at 1,61A.
R106, R107 opened.
No hazard.
F No = Fault Number, S-c = Short-circuit, Dis = Disconnection
Click on the first or last page to see other AVR 230 (serv.man12) service manuals if exist.