Harman Kardon AVR 230 (serv.man12) EMC - CB Certificate ▷ View online
-
IEC 60065, 6th edition : 1998
-
- Page 8 of 37 -
Order
No.
14399
7.1
Operating conditions (power audio amplifier, 1/8 of maximum non clipped output):
U
=
254,4
V, I
=
1,62
A, P
=
310
W,
Pout =
2 x 7,0
W
(F)
1 x 6,9
W
(C)
2 x 7,0
W
(S)
1
x
6,9
W
(S/B)
LSL =
6 channels x 8
Ω
Loudspeaker
system(s)
Right and Left for Front,
Only one for Center,
Right and Left for Surround,
Only one for Surround Back channels.
Marking of loudspeaker terminals
FRONT, CENTER, SURROUND, SURR.BACK,
SPEAKERS ( 8
Ω ).
U =
254,4
V
6 Ohm
8 Ohm
16 Ohm
left left
right right left
right
left
right
Measured max. output voltage in Vp
F)
30,0
C) 29,8
S) 29,9
S/B) 29,7
S) 29,9
S/B) 29,7
F) 30,0
C) -
S) 29,9
S/B) -
C) -
S) 29,9
S/B) -
Measured max. output power in W
F)
56,1
C) 55,4
S) 56,0
S/B) 55,3
S) 56,0
S/B) 55,3
F) 56,1
C) -
S) 56,0
S/B) -
C) -
S) 56,0
S/B) -
Measured max. mains power in W
734
Operation of protective devices
No fuse links operate during normal operating condition
P
7.1.1
Temperature rise of accessible parts
(see table next page)
P
7.1.2
Temperature rise of parts providing
electrical insulation
electrical insulation
(see table next page)
P
7.1.3
Temperature rise of parts acting as a
support or as a mechanical barrier
support or as a mechanical barrier
(see table next page)
P
7.1.4
Temperature rise of windings
(see table next page)
P
7.1.5
Parts not subject to a limit under
7.1.1 to 7.1.4
7.1.1 to 7.1.4
(see table next page)
P
-
IEC 60065, 6th edition : 1998
-
- Page 9 of 37 -
Order
No.
14399
HEATING
∆t = ( R2 - R1) x (234,5 + t1) - (t2 - t1)
R1
R1
P
t1 =
24,5 °C
24,5 °C
t2 =
23,3 °C
22,1 °C
Test voltage
207 V
254,4 V
Winding
R1/
Ω R2/Ω
∆t measured
∆t allowed *
Insulation
class
class
Main transf. pr. winding (207V)
2,42
2,93
55,8
85
Class E
Sub transf. pr. winding (207V)
2728
3141
40,4
85
Class E
Main transf. pr. winding (254,4V)
2,42
3,08
73,0
85
Class E
Sub transf. pr. winding (254,4V)
2728
3279
54,7
85
Class E
Other measured parts
∆t measured
at 207V
at 207V
∆t measured
at 254,4V
at 254,4V
∆t allowed *
Main transformer core
48,6
59,1
85
Sub transformer core
32,4
43,3
85
D992 heat-sink
58,8
62,7
-
D991 heat-sink
61,8
66,5
-
PWB near D992
56,6
60,1
85
TR, Q803 body
49,3
62,2
-
TR, Q804 body
36,5
48,7
-
TR, Q657 body
51,7
66,6
-
PWB near Q657
43,4
55,1
85
E. Capacitor, C909 body
26,6
30,4
-
E. Capacitor, C929 body
36,5
45,5
-
IC91 body
47,5
61,8
-
Main heat-sink
50,3
63,6
-
Top enclosure above main transformer
23,2
30,5
65 **)
Top enclosure above main heat-sink
34,5
42,5
65 **)
Power switch button
1,1
1,3
50
-
IEC 60065, 6th edition : 1998
-
- Page 10 of 37 -
Order
No.
14399
Comments
No other parts were observed to create any hazard due to temperature rise.
P
*) Temperature rise limits for Singapore is 10K less.
**) Directly covering part for heat-sink and transformer. The top cover is supplied with
ventilation openings covering most of the top cover. This indicate emission of heat from
internal parts and the opening area is therefore not likely to be touched during normal use.
ventilation openings covering most of the top cover. This indicate emission of heat from
internal parts and the opening area is therefore not likely to be touched during normal use.
7.2
Softening temperature of insulating
material supporting parts
conductively connected to the mains
carrying a current > 0,2 A at least
150
material supporting parts
conductively connected to the mains
carrying a current > 0,2 A at least
150
°C
No temperature measured during heating test and fault
cond. tests requires this test (7.2) to be performed.
cond. tests requires this test (7.2) to be performed.
N
Tested parts
Temperature
under normal
operating con-
ditions (°C)
under normal
operating con-
ditions (°C)
Temperature
under fault
conditions
(°C)
under fault
conditions
(°C)
Softening
temperature
(°C)
temperature
(°C)
-
IEC 60065, 6th edition : 1998
-
- Page 11 of 37 -
Order
No.
14399
8 CONSTRUCTIONAL
REQUIREMENTS WITH REGARD
TO THE PROTECTION AGAINST
ELECTRIC SHOCK
TO THE PROTECTION AGAINST
ELECTRIC SHOCK
P
8.1
Conductive parts covered by
lacquer, paper, untreated textile
oxide films and beads etc.
considered to be bare
lacquer, paper, untreated textile
oxide films and beads etc.
considered to be bare
Considered
P
8.2
Shock hazard when changing
voltage setting device, fuse-links or
handling drawers etc.
voltage setting device, fuse-links or
handling drawers etc.
Operation “By hand” not possible
N
8.3
Insulation of hazardous live parts not
provided by hygroscopic material
provided by hygroscopic material
No hygroscopic materials
N
8.4
Risk of electric shock from
accessible parts, including when
covers are removed by hand.
accessible parts, including when
covers are removed by hand.
No cover removable by hand.
N
8.5
Class I equipment
Class II equipment
N
Basic insulation between hazardous
live parts and earthed accessible
parts
live parts and earthed accessible
parts
N
Resistors bridging basic insulation
complying with 14.1 a)
complying with 14.1 a)
N
Capacitors bridging basic insulation
complying with 14.2.1 a)
complying with 14.2.1 a)
N
Basic insulation bridged by
components complying with 14.3.4.3
components complying with 14.3.4.3
N
Protective earth contact
N
8.6
Class II equipment and Class II
constructions within Class I
equipment
constructions within Class I
equipment
P
Reinforced or double insulation
between hazardous live parts and
accessible parts
between hazardous live parts and
accessible parts
Double/Reinforced insulation complies with requirements
specified in clause 10 and 13.
specified in clause 10 and 13.
P
Components bridging reinforced or
double insulation complying with
14.1 a) or 14.3
double insulation complying with
14.1 a) or 14.3
The apparatus has an isolating transformer
P
Basic and supplementary insulation
each being bridged by a capacitor
complying with 14.2.1 a)
each being bridged by a capacitor
complying with 14.2.1 a)
N
Reinforced or double insulation
being bridged by 2 capacitors in
series complying with 14.2.1 a)
being bridged by 2 capacitors in
series complying with 14.2.1 a)
N
Reinforced or double insulation
being bridged by a single capacitor
complying with 14.2.1 b)
being bridged by a single capacitor
complying with 14.2.1 b)
N