DOWNLOAD Harman Kardon AVR 171 (serv.man6) Service Manual ↓ Size: 1.28 MB | Pages: 47 in PDF or view online for FREE

Model
AVR 171 (serv.man6)
Pages
47
Size
1.28 MB
Type
PDF
Document
EMC - CB Certificate
Brand
Device
Audio
File
avr-171-sm6.pdf
Date

Harman Kardon AVR 171 (serv.man6) EMC - CB Certificate ▷ View online

Reference No. : 54121302G                                                                                                                  Page 25/47
 
◀  Anam EMC Test Laboratory  ▶
 
6DB
ANAM EMC Testing Lab.
150 kHz
30 MHz
dBµV
 
dBµV
 
2 AV
CLRWR
SGL
1 PK
CLRWR
RBW
 9 kHz
MT
 10 ms
PREAMP OFF
Att 25 dB
28.Jan 13 16:21
1 MHz
10 MHz
-10
0
10
20
30
40
50
60
70
80
90
1
Marker 1 [T1 ]
          57.22 dBµV
   150.000000000 kHz
A4_AV
A4_QP
AVR171/230_Nonground line2(1KHz sine wave input FM 87.5MHz)
Date: 28.JAN.2013  16:21:32
Reference No. : 54121302G                                                                                                                  Page 26/47
 
◀  Anam EMC Test Laboratory  ▶
 
6DB
ANAM EMC Testing Lab.
150 kHz
30 MHz
dBµV
 
dBµV
 
2 AV
CLRWR
SGL
1 PK
CLRWR
RBW
 9 kHz
MT
 1 s
PREAMP OFF
Att 25 dB
28.Jan 13 16:13
1 MHz
10 MHz
-10
0
10
20
30
40
50
60
70
80
90
1
Marker 1 [T1 ]
          54.54 dBµV
   150.000000000 kHz
A4_AV
A4_QP
AVR171/230_Nonground line1(1KHz sine wave input USB)
Date: 28.JAN.2013  16:13:11
Reference No. : 54121302G                                                                                                                  Page 27/47
 
◀  Anam EMC Test Laboratory  ▶
 
6DB
ANAM EMC Testing Lab.
150 kHz
30 MHz
dBµV
 
dBµV
 
2 AV
CLRWR
SGL
1 PK
CLRWR
RBW
 9 kHz
MT
 10 ms
PREAMP OFF
Att 25 dB
28.Jan 13 16:16
1 MHz
10 MHz
-10
0
10
20
30
40
50
60
70
80
90
1
Marker 1 [T1 ]
          53.58 dBµV
   150.000000000 kHz
A4_AV
A4_QP
AVR171/230_Nonground line2(1KHz sine wave input USB)
Date: 28.JAN.2013  16:16:45
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
Reference No. : 54121302G                                                                                                                  Page 28/47
 
◀  Anam EMC Test Laboratory  ▶
 
 
Annex B : Antenna terminal disturbance voltage 
6DB
dBµV
 
dBµV
 
1 PK
CLRWR
30 MHz
2.7 GHz
ANAM EMC Testing Lab.
MT
 100 µs
RBW
 120 kHz
PREAMP OFF
Att 10 dB
28.Jan 13 19:11
100 MHz
1 GHz
0
10
20
30
40
50
60
70
80
90
100
1
Marker 1 [T1 ]
          47.31 dBµV
    87.480000000 MHz
AVR171/230_FM 87.5MHz
Date: 28.JAN.2013  19:11:02
Page of 47
Display

Click on the first or last page to see other AVR 171 (serv.man6) service manuals if exist.