Harman Kardon AVR 171 (serv.man6) EMC - CB Certificate ▷ View online
Reference No. : 54121302G Page 13/47
◀ Anam EMC Test Laboratory ▶
OTHERS
Antenna terminal disturbance voltage due to other source than local oscillator.
Channel Harmonic
Measured
freq. (㎒)
Limit(㏈㎶)
Disturbance
value(㏈㎶)
98.0 / 46.0 *
*: less than 30 ㏈㎶
Limit
according
to
EN55013:2001+A2(2006)
For the measurement data, see Annex B (3 Copies).
8. DISTURBANCE POWER
8.1. Operating environment
Temperature
: 13℃
Relative humidity : 41%
8.2. Test set-up and procedure
The EUT was placed on a non-metallic table of 0.8m height. At the side of the
EUT a non-metallic table of 6m length was placed to provide for movement of
the absorbing clamp. The absorbing clamp was applied successively to all leads
whose length was 25 ㎝ or longer, unscreened or screened. For the read, the
maximum measured value at each frequency which was obtained when the
absorbing clamp is moved along the lead was registered. No metallic object,
including a possible other unit of the EUT or any person, was closer to the lead
or unit than 0.8m. All screened and unscreened cables were measured with an
absorbing clamp, according to EN55013, 5.6.
absorbing clamp, according to EN55013, 5.6.
8.3. Measurement uncertainty
Radio interference power: ±2.0 ㏈
The Measurement uncertainty describes the overall uncertainty of the given
measured value during operation of the EUT in the above-mentioned way.
measured value during operation of the EUT in the above-mentioned way.
8.4. Test instrumentation
Equipment
Manufacturer
Type No.
Serial No.
Measurement
receiver
receiver
R & S
ESCI
100348
Test Compact Disc
Abex
TCD-782
N/A
Absorbing clamp
R & S
MDS 21
860846/006
R. C. Oscillator
Kenwood
AG-203A
3090241
* R & S: Rohde & Schwarz
Reference No. : 54121302G Page 14/47
◀ Anam EMC Test Laboratory ▶
8.5. Test protocols
Date: January 28, 2013
The equipment does comply with the requirements. Operating condition: The
EUT continuously operated with audio frequency of 1,000 ㎐ color bar being
supplied from the Oscillator or test CD. An absorbing clamp was placed
around all leads. At each mode, the maximum value at each testing frequency
and each output lead was registered and attached as follows.
Test Lead
Freq.
(㎒)
Limit(㏈㎺) Result(㏈㎺)
QP AV QP AV
PHONES
41.70
45.4 35.4 23.7 19.2
ANALOG 1
257.80
53.4
43.4
*
*
ANALOG 2
257.80
53.4
43.4
*
*
ZONE 2 OUT
257.80
53.4
43.4
*
*
SUBWOOFER PRE OUT
257.80
53.4
43.4
*
*
COAXIAL 257.80
53.4
43.4
* *
VIDEO IN/OUT
257.80
53.4
43.4
*
*
IR IN
257.80
53.4
43.4
*
*
TRIGGER OUT
257.80
53.4
43.4
*
*
ZONE 2 IR IN
257.80
53.4
43.4
*
*
HDMI IN/OUT
257.80
53.4
43.4
*
*
SPEAKER
221.19
52.1 42.1 23.9 21.3
AC
POWER
CORD 35.78
45.2 35.2 22.9 16.5
*: less than 25 ㏈㎺
Limit
according
to
EN55013:2001+A2(2006)
Reference No. : 54121302G Page 15/47
◀ Anam EMC Test Laboratory ▶
Note:1) The spectrum was checked from 30 to 300 ㎒.
2) The cable (6.0m length) loss is included in a correction factor.
3) Detector function of the measuring instrument:
QP: Quasi-peak, AV: Average
4) QP line: Limit (㏈㎺) = Frequency (㎒) ×0.037 + 43.9
AV line: Limit (㏈㎺) = Frequency (㎒) ×0.037 + 33.9
5) *: Less than 25 ㏈㎺
For the measurement data, see Annex C (13 Copies)
9. HARMONICS
9.1. Operating environment
Temperature
: 21℃
Relative humidity : 38%
9.2. Test set-up and procedure
Harmonics of the fundamental current were measured up to 2 ㎑ using a
universal power analyzer. The measurement was carried out under steady
conditions and using averaging.
The Class of this equipment is “Class A” by clause 5 of EN61000-3-2(2006)
The measurement was performed with the Test software for Windows
The input signal and load conditions were set as given in clause C.3
The input signal and load conditions were set as given in clause C.3
9.3. Test instrumentation
Equipment
Mfr.
Type No.
Serial No.
R. C. Oscillator
Kenwood
AG-203A
3090241
Universal power analyzer Voltech
PM6000
100006700178
Test Compact Disc
Abex
TCD-782
N/A
Programmable controller
Pacific
360AMXT/UPC32
151
Magnetics module
Pacific
134310
334
9.4. Test result
The equipment does comply with the requirements.
For the measurement data, see Annex C (3 Copies).
For the measurement data, see Annex C (3 Copies).
Reference No. : 54121302G Page 16/47
◀ Anam EMC Test Laboratory ▶
10. VOLTAGE FLUCTUATIONS-FLICKER
10.1. Operating environment
Temperature
: 21℃
Relative humidity : 38%
10.2. Test set-up and procedure
The open circuit test voltage was the rated voltage of the EUT.
The reference impedance was a conventional impedance being used to calculate
or measure the disturbance caused by an appliance.
or measure the disturbance caused by an appliance.
The measurement was performed with the Test software for Windows
10.3. Test instrumentation
Equipment
Mfr.
Type No.
Serial No.
R. C. Oscillator
Kenwood
AG-203A
3090241
Test Compact Disc
Abex
TCD-782
N/A
Reference impedance
Voltech
IEC Standard 555
IB16/0725
Universal power analyzer Voltech
PM6000
100006700178
Programmable controller
Pacific
360AMXT/UPC32
151
Magnetics module
Pacific
134310
334
10.4. Test result
The equipment does comply with the requirements.
For the measurement data, see Annex D (1 Copy).
Click on the first or last page to see other AVR 171 (serv.man6) service manuals if exist.