DOWNLOAD Harman Kardon AVR 170 (serv.man2) Service Manual ↓ Size: 1.38 MB | Pages: 40 in PDF or view online for FREE

Model
AVR 170 (serv.man2)
Pages
40
Size
1.38 MB
Type
PDF
Document
EMC - CB Certificate
Brand
Device
Audio
File
avr-170-sm2.pdf
Date

Harman Kardon AVR 170 (serv.man2) EMC - CB Certificate ▷ View online

Reference No. : 54121205C                                                                                                                  Page 13/40
 
◀  Anam EMC Test Laboratory  ▶
 
 
OTHERS 
Antenna terminal disturbance voltage due to other source than local oscillator. 
Channel Harmonic 
Measured 
freq. (㎒) 
Limit(㏈㎶) 
Disturbance 
value(㏈㎶) 
98.0   / 46.0 * 
 
*: less than 30 ㏈㎶ 
    
 
 
 
Limit 
according 
to 
EN55013:2001+A2(2006) 
        For the measurement data, see Annex B (3 Copies). 
 
8. DISTURBANCE POWER 
8.1. Operating environment 
Temperature 
: 23℃ 
Relative humidity  : 37% 
 
      8.2. Test set-up and procedure 
 
The EUT was placed on a non-metallic table of 0.8m height. At the side of the 
 
EUT a non-metallic table of 6m length was placed to provide for movement of 
 
the absorbing clamp. The absorbing clamp was applied successively to all leads 
 
whose length was 25 ㎝  or longer, unscreened or screened. For the read, the 
 
maximum measured value at each frequency which was obtained when the 
 
absorbing clamp is moved along the lead was registered. No metallic object, 
 
including a possible other unit of the EUT or any person, was closer to the lead 
 
or unit than 0.8m. All screened and unscreened cables were measured with an 
absorbing clamp, according to EN55013, 5.6. 
 
   8.3. Measurement uncertainty 
 
Radio interference power:  ±2.0 ㏈ 
 
The Measurement uncertainty describes the overall uncertainty of the given   
measured value during operation of the EUT in the above-mentioned way. 
 
   8.4. Test instrumentation 
Equipment 
Manufacturer 
Type No. 
Serial No. 
Measurement 
receiver 
R & S 
ESCI 
100348 
Test Compact Disc 
Abex 
TCD-782 
N/A 
Absorbing clamp 
R & S 
MDS 21 
860846/006 
R. C. Oscillator 
Kenwood 
AG-203A 
3090241 
 
* R & S: Rohde & Schwarz 
 
 
Reference No. : 54121205C                                                                                                                  Page 14/40
 
◀  Anam EMC Test Laboratory  ▶
 
 
8.5. Test protocols 
 
Date: May 25, 2012 
 
The equipment does comply with the requirements. Operating condition: The   
 
EUT continuously operated with audio frequency of 1,000 ㎐ color bar being 
 
supplied from the Oscillator or test CD. An absorbing clamp was placed 
 
around all leads. At each mode, the maximum value at each testing frequency 
 
and each output lead was registered and attached as follows. 
Test Lead 
Freq. 
(㎒) 
Limit(㏈㎺) Result(㏈㎺) 
QP AV QP  AV 
PHONES 
43.50 
45.5 35.5 38.7  21.3 
AUX 
172.03 
50.3 
40.3 
24.3 20.8 
REC OUT 
150.00 
49.5 39.5  * 
ANALOG IN 
150.00 
49.5 39.5  * 
COAXIAL 
150.00 
49.5 39.5  * 
COMPOSITE 
150.00 
49.5 39.5  * 
SUBWOOFER PRE OUT 
150.00 
49.5 39.5  * 
HDMI IN/OUT 
172.03 
50.3 
40.3 
* * 
SPEAKER 
172.03 
50.3 
40.3 
23.3 19.5 
AC POWER CORD 
172.03 
50.3 
40.3 
22.5 18.3 
TRIGGER OUT 
172.03 
50.3 
40.3 
* * 
IR IN 
172.03 
50.3 
40.3 
* * 
 
 
 
 
 
 
*: less than 25 ㏈㎺ 
    
Limit 
according 
to 
EN55013:2001+A2(2006)
 
 
Note:1) The spectrum was checked from 30 to 300 ㎒. 
 
     2) The cable (6.0m length) loss is included in a correction factor. 
 
     3) Detector function of the measuring instrument:  
 
 
QP: Quasi-peak, AV: Average 
 
     4) QP line: Limit (㏈㎺) = Frequency (㎒)  ×0.037 + 43.9 
 
              AV line: Limit (㏈㎺) = Frequency (㎒)  ×0.037 + 33.9 
 
     5) *: Less than 25 ㏈㎺ 
 
For the measurement data, see Annex C (12 Copies). 
 
 
 
 
 
Reference No. : 54121205C                                                                                                                  Page 15/40
 
◀  Anam EMC Test Laboratory  ▶
 
 
9. Photograph of the EUT 
9.1 Front of the EUT 
 
9.2 Rear of the Product 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
Reference No. : 54121205C                                                                                                                  Page 16/40
 
◀  Anam EMC Test Laboratory  ▶
 
 
9.3 Inside view 1 of Product   
 
 
9.4 Inside view 2 of the Product   
 
 
 
 
Page of 40