Report No.: 162888 
 
 
ATTACHMENT 3 
Clause 
Requirement + Test 
 Result - Remark 
Verdict 
 
TRF No. IEC60065J 
 
 
 
16.2 
Delete the note. 
 
N/A 
20 
Delete note 2. 
 
N/A 
Annex B 
Replace note 1 by: 
In the CENELEC countries listed in IEC 62151, 
special national conditions apply. 
No TNV circuits. 
N/A 
Annex G 
Delete the note. 
 
N/A 
Annex J.2 
Delete the notes of Table J.1. 
 
N/A 
Annex N 
Add after the introduction: 
For ROUTINE TEST reference is made to EN 
50333. 
Considered. 
Bibliograp
hy 
 
Add the following standards: 
EN 60332-1: 2000, Sound system equipment: Headphones and earphones 
associated with portable audio equipment – 
Maximum sound pressure level measurement methodology and limit considerations 
– Part 1: General method for”one package equipment”. 
PrEN 50332-2 (uder consideration), Sound system equipment: Headphones and 
earphones associated with portable 
audio equipment – Maximum sound pressure level measurement methodology and 
limit considerations – Part 2: 
Guidelines to associate sets with headphones coming from different manufacturers. 
Add the following notes for the standards indicated: 
 
IEC 60130 
NOTE  Parts 9 and 17: 1998 are harmonized as Ens (not 
modified). 
IEC 60169  
NOTE   Partly harmonized in the EN 60169/HD 134 series (not 
modified). 
IEC 60173  
NOTE   Harmonized as HD 27 S1: 1978 (not modified). 
IEC 60335-2-56  
NOTE  Harmonized as EN 60335-2-56: 1997 (not 
modified). 
IEC 60335-2-82  
NOTE   Harmonized as EN 60335-2-82: 2000 (not 
modified). 
IEC 60695  
NOTE   Harmonized as EN 60695 series (not modified). 
IEC 61040  
NOTE   Harmonized as EN 61040: 1992 (not modified). 
IEC 61558-2-1   NOTE  Harmonized as EN 61558-2-1: 1997 (not modified). 
IEC 61558-2-4   NOTE   Harmonized as EN 61558-2-4: 1997 (not modified). 
IEC 61558-2-6  NOTE   Harmonized as EN 61558-2-6: 1997 (not modified). 
 
 
 
Page 4 of 10 
 
Report No.: 162888 
 
 
ATTACHMENT 3 
Clause 
Requirement + Test 
 Result - Remark 
Verdict 
 
TRF No. IEC60065J 
 
 
 
Annex ZA 
(normativ
e) 
Other international publications quoted in this standard with the references of 
the relevant European publications 
This European Standard incorporates by dated or undated reference, provisions 
from other publications. These normative references are cited at the appropriate 
places in the text and the publications are listed hereafter. For dated references, 
subsequent amendments to or revisions of any of these publications apply to this 
European Standard only when incorporated in it by amendment or revision. For 
undated references the latest edition of the publication referred to applies (including 
amendments). 
 
NOTE When an international standard has been modified by common modification, 
indicated by (mod), the relevant EN/HD applies. 
 
 
 
 
Page 5 of 10 
 
Report No.: 162888 
 
 
ATTACHMENT 3 
Clause 
Requirement + Test 
 Result - Remark 
Verdict 
 
TRF No. IEC60065J 
 
 
 
Annex ZA 
Cont. 
 
 
 
 
 
Page 6 of 10 
 
Report No.: 162888 
 
 
ATTACHMENT 3 
Clause 
Requirement + Test 
 Result - Remark 
Verdict 
 
TRF No. IEC60065J 
 
 
 
Annex ZA 
Cont. 
 
GROUP DIFFERENCES FOR AMENDMENT 1 
COMMON MODIFICATIONS 
5.1 i) 
in EN 60065:2002 
Replace 
the note by: 
NOTE For RATED POWER CONSUMPTION measurements of TVs reference is 
made to EN 62087. Measurements are done in the ON (play) operating mode. 
N/A 
5.4.1 
 
Add the following indent: 
za) A warning that excessive sound pressure from earphones and headphones  
can cause hearing loss. 
N/A 
6.1 
 
 
6.1 
in EN 60065:2002 
Replace 
the subclause by: 
Ionizing radiation 
Equipment that might produce ionizing radiation is checked by measuring the amount of 
radiation. 
The amount of radiation is determined by means of a radiation monitor of the ionizing 
chamber type with an effective area of 1 000 mm2 or by measuring equipment of other 
types giving equivalent results. 
Measurements are made with the equipment on test operating at the most  
unfavourable supply voltage (see 4.2) and with operator controls and service controls 
adjusted so as to give maximum radiation whilst maintaining the equipment operative  
for normal use. 
Internal preset controls not intended to be adjusted during the lifetime of the equipment 
are not considered to be service controls. 
At any point 100 mm from the surface of the operator access area, the dose-rate shall 
not exceed 1 
μSv/h (0,1 mR/h) (see Note). Account shall be taken of the background 
level. 
NOTE These values appear in Directive 96/29/Euratom. 