Harman Kardon AVR 158 (serv.man6) EMC - CB Certificate ▷ View online
Page 35 of 46
Report No.: 162888
TRF No. IEC60065J
Measured at 1/8 of maximum non-clipped output at 50Hz
Un (V)
In (A)
Pn (W)
Pout (W)
198
*) 0.93
**) 0.79
*) 149.0
**) 125.0
2 x 4.15W
(F)
1 x 4.20 W
(C)
2 x 4.15 W
(S)
220
*) 0.95
**) 0.80
*) 168.0
**) 139.0
240
*) 0.97
**) 0.81
*) 185.0
**) 153.0
264
*) 1.00
**) 0.83
*) 208.0
**) 171.0
Measured at 1/8 of maximum non-clipped output at 60Hz
Un (V)
In (A)
Pn (W)
Pout (W)
198
*) 0.93
**) 0.79
*) 149.0
**) 124.0
2 x 4.15W
(F)
1 x 4.20 W
(C)
2 x 4.15 W
(S)
220
*) 0.95
**) 0.80
*) 167.0
**) 139.0
240
*) 0.97
**) 0.81
*) 184.0
**) 152.0
264
*) 1.00
**) 0.83
*) 206.0
**) 169.0
Measured at, *) HIGH (S1A) mode **) LOW (S1B) mode
of the main transformer S1A or S1B output (selected by RY21).
of the main transformer S1A or S1B output (selected by RY21).
Tested condition: 1kHz input signal, connected 8 ohm loads for F, C, S channels
Loudspeaker impedance (Ω) ......................
8 Ohm
—
Several loudspeaker systems
Right and Left for Front,
Right and Left for Surround,
Only one for Center.
Right and Left for Surround,
Only one for Center.
P
Marking of loudspeaker terminals
SPEAKERS (8
Ω):
FRONT RIGHT, FRONT LEFT,
SURR. RIGHT, SURR. LEFT, CENTER.
SURR. RIGHT, SURR. LEFT, CENTER.
P
Page 36 of 46
Report No.: 162888
TRF No. IEC60065J
Monitored point:
dT (K) at
198V/50Hz
dT (K) at
264V/50Hz
dT (K) at
198V/60Hz
dT (K) at
264V 60Hz
Permitted
dT (K) *)
Main transformer core
38.7
49.5
40.9
48.1
85
Sub transformer core
24.9
29.8
25.8
29.2
85
PWB near D991
40.1
43.0
40.5
42.8
95
PWB near D105
25.9
25.0
26.3
24.8
95
PWB near Q803
29.6
41.6
30.3
40.9
95
PWB near IC91
29.1
43.5
29.7
43.1
95
E Capacitor, C915 body
19.0
22.4
19.9
22.4
85
°C
CN91 AC connector
17.4
22.1
17.9
20.6
-
CN92 AC connector
15.3
18.3
16.2
18.0
-
Heat-sink of D991
53.8
57.6
54.7
57.3
-
Main heat-sink
33.4
48.4
34.0
47.8
-
Enclosure top above main transformer
17.5
22.1
18.4
21.6
40
Enclosure top above main heat-sink
20.0
29.5
21.5
29.2
40
Mains switch (rear side)
7.8
9.5
8.4
9.4
50
Inlet body
7.9
9.6
8.6
9.4
60
Stand-by button (non-metallic)
3.3
5.0
3.7
4.6
60
Front panel (non-metallic)
5.6
7.9
5.9
7.8
60
Ambient
22.3°C
23.6°C
22.9°C
22.8°C
-
*) Temperature rise limits for tropical climate is 10K less. Comply
Page 37 of 46
Report No.: 162888
TRF No. IEC60065J
Winding temperature rise
measurements
198V
50Hz
50Hz
264V
50Hz
50Hz
198V
60Hz
60Hz
264V
60Hz
60Hz
Ambient temperature t1 (
o
C) Main / Sub
:
23.6 / 22.
0
23.6 / 22.
0
23.6 / 22.
0
23.6 / 22.
0
Ambient temperature t2 (
o
C) :
23.3
23.6
23.3
23.0
Temperature rise dT of winding:
R
1
(Ω)
R
2
(Ω)
dT (K)
Permitted
dT (K)
Insulatio
n class
Main transf. primary winding (198V, 50Hz)
6.261
7.397
47.1
85
E
Sub transf. primary winding (198V, 50Hz)
3788
4265
31.0
85
E
Main transf. primary winding (264V, 50Hz)
6.261
7.748
61.3
85
E
Sub transf. primary winding (264V, 50Hz)
3788
4368
37.7
85
E
Main transf. primary winding (198V, 60Hz)
6.261
7.447
49.2
85
E
Sub transf. primary winding (198V, 60Hz)
3788
4251
30.1
85
E
Main transf. primary winding (264V, 60Hz)
6.261
7.691
59.6
85
E
Sub transf. primary winding (264V, 60Hz)
3788
4333
35.9
85
E
7.2
TABLE: softening temperature of thermoplastics
P
Temperature T of part
T – normal con-
ditions (
o
C)
T – fault condi-
tions (
o
C)
Min T softening
(
o
C)
AC connector (CN91)
22.1 (45.7 °C)
(I/P=264V,
ambient 23.6 °C)
(I/P=264V,
ambient 23.6 °C)
35.0 (59.3 °C)
(I/P=264V,
ambient 24.3 °C)
(I/P=264V,
ambient 24.3 °C)
> 200
(type, YW396 series)
(type, YW396 series)
AC connector (CN92)
18.3 (41.9 °C)
(I/P=264V,
ambient 23.6 °C)
(I/P=264V,
ambient 23.6 °C)
32.5 (56.8 °C)
(I/P=264V,
ambient 24.3 °C)
(I/P=264V,
ambient 24.3 °C)
> 200
(type, YW396 series)
(type, YW396 series)
Page 38 of 46
Report No.: 162888
TRF No. IEC60065J
9.1.1.1
Touch current expressed as voltages U1 and U2 in Annex D
P
Location
Measured
U1V (peak)
U1V (peak)
Measured
U1 V (DC)
U1 V (DC)
Measured
U2 V (peak)
U2 V (peak)
Limits :
U1 Max 35V (peak)
U1 Max 1.1V (DC)
U2 Max 0.35V (peak)
U1 Max 35V (peak)
U1 Max 1.1V (DC)
U2 Max 0.35V (peak)
Pole 1 – Antenna terminal
Pole 2 – Antenna terminal
Pole 2 – Antenna terminal
-
-
-
-
-
-
0.03V peak
0.03V peak
0.03V peak
Pass
Pass
Pass
Pole 1 – other part or contact
Pole 2 – other part or contact
Pole 2 – other part or contact
-
-
-
-
-
-
0.03V peak
0.03V peak
0.03V peak
Pass
Pass
Pass
Comments:
Vin = 264Vac / 60Hz
Only U2 have been recorded due to the use of a linear transformer in power supply.
10.3
TABLE: insulation resistance measurements
P
Insulation resistance R between:
R (MΩ)
Required R (MΩ)
Between mains poles (primary fuse disconnected)
Min. 100
Min 2
Between parts separated by double or reinforced insulation
Min. 100
Min 4
Between mains poles (primary fuse disconnected)
after humidity test
after humidity test
Min. 50
Min 2
Between parts separated by double or reinforced insulation
after humidity test
after humidity test
Min. 80
Min 4
10.3
TABLE: electric strength measurements
P
Test voltage applied between:
Test voltage (V)
Breakdown
Mains poles (primary fuse disconnected)
1500 Vac
No
Between parts separated by double or reinforced insulation
3000 Vac
No
Between mains poles (primary fuse disconnected)
after humidity test
after humidity test
1500 Vac
No
Between parts separated by double or reinforced insulation
after humidity test
after humidity test
3000 Vac
No
Between mains poles (primary fuse disconnected)
after components abnormal operated test
after components abnormal operated test
1500 Vac
No
Between parts separated by double or reinforced insulation
after components abnormal operated test
after components abnormal operated test
3000 Vac
No
Click on the first or last page to see other AVR 158 (serv.man6) service manuals if exist.