DOWNLOAD Harman Kardon AVR 158 (serv.man6) Service Manual ↓ Size: 2.93 MB | Pages: 85 in PDF or view online for FREE

Model
AVR 158 (serv.man6)
Pages
85
Size
2.93 MB
Type
PDF
Document
EMC - CB Certificate
Brand
Device
Audio
File
avr-158-sm6.pdf
Date

Harman Kardon AVR 158 (serv.man6) EMC - CB Certificate ▷ View online

 
 
 
Page 31 of 46 
 
Report No.: 162888 
 
 
 
 
 
 
 
 
IEC 60065 
Clause 
Requirement + Test 
 
Result - Remark 
Verdict 
 
TRF No. IEC60065J 
 
 
 
20.2 
Fire enclosure  
No fire enclosure. 
N/A 
20.2.1 
Potential ignition sources with open circuit voltage 
> 4 kV (peak) a.c. or d.c. contained in a fire 
enclosure to V-1  
 
N/A 
20.2.2 
Internal fire enclosures with openings not exceeding 
1 mm in width and with openings for wires 
completely filled  
 
N/A 
20.2.3 
Requirements of 20.2.1 and 20.2.2 met by an 
internal fire enclosure  
 
N/A 
 
 
 
 
Page 32 of 46 
 
Report No.: 162888 
 
 
 
 
 
 
 
 
IEC 60065 
Clause 
Requirement + Test 
 
Result - Remark 
Verdict 
 
TRF No. IEC60065J 
 
 
 
Annex A, Additional requirements for apparatus with protection against 
splashing water 
 
A.5 
Marking and instructions 
 
N/A 
A.5.1 
j) Marked with IPX4 (IEC 60529), 5.4.1 a) does not 
apply  
Not intended for outdoor use 
N/A 
A.10 
Insulation requirements 
 
N/A 
A.10.2 
Splash and humidity treatment 
 
N/A 
A.10.2.1 
Enclosure provides protection against splashing 
water  
 
N/A 
A.10.2.2 
Humidity treatment carried out for 7 days  
 
N/A 
 
Annex B, Apparatus to be connected to the TELECOMMUNICATION 
NETWORKS 
 
 
Complies with IEC 62151 clause 1  
No TNV circuits 
N/A 
 
Complies with IEC 62151 clause 2  
 
N/A 
 
Complies with IEC 62151 clause 3 but with 3.5.4 
modified to 2.4.10 of this standard  
 
N/A 
 
Complies with IEC 62151 clause 4 but with 4.1.2, 
4.1.3 and 4.2.1.2 modified in accordance with 
annex B of this standard  
 
N/A 
 
Complies with IEC 62151 cause 5 but with 5.3.1 
modified in accordance with annex B of this  
standard  
 
N/A 
 
Complies with IEC 62151 clause 6  
 
N/A 
 
Complies with IEC 62151 clause 7  
 
N/A 
 
Complies with IEC 62151 annex A, B and C  
 
N/A 
 
ANNEX L, Additional requirements for electronic flash apparatus for 
photographic purposes 
 
L. 5 
Marking and instructions 
 
N/A 
L. 5.4 
Instructions for battery chargers and Supply 
apparatus indicating type or model number of flash 
apparatus with which it is to be used  
No electronic flash apparatus. 
N/A 
 
Instructions for flash apparatus indicating type or 
model number of battery chargers or Supply 
apparatus with which it is to be used  
 
N/A 
L. 7 
Heating under normal operating conditions 
 
N/A 
 
 
 
Page 33 of 46 
 
Report No.: 162888 
 
 
 
 
 
 
 
 
IEC 60065 
Clause 
Requirement + Test 
 
Result - Remark 
Verdict 
 
TRF No. IEC60065J 
 
 
 
L7.1.5 & 
L11.2.6 
Lithium batteries meet permissible temp rise in 
Table  3 , unless comply with 6.2.2.1.or 6.2.2.2 of 
IEC 60086-4  
No lithium batteries 
N/A 
L. 9 
Electric shock hazard under normal operating 
conditions 
Not flash synchroniser. 
N/A 
L. 9.1.1 
Terminals to connection to synchroniser not 
HAZARDOUS LIVE  
 
N/A 
L.10 
Insulation requirements 
 
N/A 
L. 10.3.2 
High frequency puls ignition  
 
N/A 
L. 12 
Mechanical strength 
 
N/A 
L. 12.1.3 
Windows for flash tubes are excluded from steel 
ball impact test  
 
N/A 
L. 14 
Components 
 
N/A 
L14.6.6 
Mains switch characteristics appropriate to its 
function under normal conditions  
 
N/A 
L. 20 
Resistance to fire 
 
N/A 
L. 20.1 c) 
Trigger coil for discharge purpose is not considered 
to be a POTENTIAL IGNITION SOURCE  
 
N/A 
 
 
 
 
Page 34 of 46 
 
Report No.: 162888 
 
 
TRF No. IEC60065J 
 
 
 
7.1 
TABLE: temperature rise measurements 
 
Power consumption in the OFF/Stand-by…..: 
Less than 0.51W 
— 
 
Position of the functional switch (W) ……..: 
— 
Operating conditions 
Standby mode 50Hz 
Un (V) 
In (A) 
Pn (W) 
Pout (W) 
220 
0.003 
0.42 
— 
230 
0.004 
0.47 
 
240 
0.004 
0.51 
— 
 
 
 
 
Standby mode 60Hz 
Un (V) 
In (A) 
Pn (W) 
Pout (W) 
220 
0.003 
0.40 
— 
230 
0.003 
0.42 
 
240 
0.003 
0.46 
— 
 
 
 
 
Measured at maximum non-clipped output at 50Hz 
Un (V) 
In (A) 
Pn (W) 
Pout (W) 
264 
1.70 
387 
2 x 33.2 W 
(F) 
1 x 33.6 W 
(C) 
2 x 33.2 W 
(S) 
 
 
 
 
Measured at maximum non-clipped output at 60Hz 
Un (V) 
In (A) 
Pn (W) 
Pout (W) 
264 
1.69 
386 
2 x 33.2 W 
(F) 
1 x 33.6 W 
(C) 
2 x 33.2 W 
(S) 
 
 
 
 
Measured at LOW mode of the main transformer S1B output (selected by RY21).
 
Tested condition: 1kHz input signal, connected 8 ohm loads for F, C, S channels 
 
Page of 85
Display