Harman Kardon AVR 142 (serv.man3) EMC - CB Certificate ▷ View online
- Page 27 of 42 -
Report
No.
123035
IEC 60065
Clause
Requirement – Test
Result - Remark
Verdict
TRF No. IEC60065_I
20.2
Fire enclosure
N/A
20.2.1
Potential ignition sources with open circuit voltage
> 4 kV (peak) a.c. or d.c. contained in a fire
enclosure to V-1 …………………..:
> 4 kV (peak) a.c. or d.c. contained in a fire
enclosure to V-1 …………………..:
No voltages exceeding 4kV,
no fire enclosure requirement
no fire enclosure requirement
N/A
20.2.2
Internal fire enclosures with openings not exceeding
1 mm in width and with openings for wires
completely filled ……………………..:
1 mm in width and with openings for wires
completely filled ……………………..:
No internal fire enclosure.
N/A
20.2.3
Requirements of 20.2.1 and 20.2.2 met by an
internal fire enclosure ……………………….:
internal fire enclosure ……………………….:
No internal fire enclosure.
N/A
- Page 28 of 42 -
Report
No.
123035
IEC 60065
Clause
Requirement – Test
Result - Remark
Verdict
TRF No. IEC60065_I
A
Annex A, Additional requirements for apparatus with protection against
splashing water
splashing water
A.5
Marking and instructions
N/A
A.5.1
j) Marked with IPX4 (IEC 60529), 5.4.1 a) does not
apply ……………………………………………….....:
apply ……………………………………………….....:
Not intended for outdoor
use.
use.
N/A
A.10.2 Insulation
requirements
N/A
A.10.2.1
Enclosure provides protection against splashing
water.................................................................:
water.................................................................:
N/A
A.10.2.2 Humidity
treatment
carried out for 7 days …………:
See clause above.
N/A
B
Annex B, Apparatus to be connected to the TELECOMMUNICATION NETWORKS
Complies with IEC 62151 clause 1 ………………..:
No TNV circuits
N/A
Complies with IEC 62151 clause 2 ………………..:
N/A
Complies with IEC 62151 clause 3 but with 3.5.4
modified to 2.4.10 of this standard ……………...…:
modified to 2.4.10 of this standard ……………...…:
N/A
Complies with IEC 62151 clause 4 but with 4.1.2,
4.1.3 and 4.2.1.2 modified in accordance with annex
B of this standard ……………………………:
4.1.3 and 4.2.1.2 modified in accordance with annex
B of this standard ……………………………:
N/A
Complies with IEC 62151 cause 5 but with 5.3.1
modified in accordance with annex B of this standard
modified in accordance with annex B of this standard
N/A
Complies with IEC 62151 clause 6 ………………..:
N/A
Complies with IEC 62151 clause 7 ………………...:
N/A
Complies with IEC 62151 annex A, B and C ……...:
N/A
IEC 62151 clause 4.1.1:
Add after the first paragraph:
Add after the first paragraph:
NOTE- In Finland, Norway and Sweden, class I equipment which
is intended for connection to the building installation via a non-
industrial plug or a non-industrial appliance coupler or both and in
addition is intended for connection to other equipment or a network
shall, if safety relies on connection to protective earth or if surge
suppressors are connected between the network terminals and
ACCESSIBLE parts, have a marking stating that the equipment
must be connected to an earthed mains socket-outlet.
is intended for connection to the building installation via a non-
industrial plug or a non-industrial appliance coupler or both and in
addition is intended for connection to other equipment or a network
shall, if safety relies on connection to protective earth or if surge
suppressors are connected between the network terminals and
ACCESSIBLE parts, have a marking stating that the equipment
must be connected to an earthed mains socket-outlet.
The marking text in the applicable countries shall be as follow:
- Finland; ”Laite on liitettävä suojamaadoituskoskettimilla va
rustettuumpistorasiaan”
- Norway; ”Apparatet mǻ tikoples jordet stikkontakt”
- In Sweden; ”Apparaten skall anslutas till jordat uttag”
- Finland; ”Laite on liitettävä suojamaadoituskoskettimilla va
rustettuumpistorasiaan”
- Norway; ”Apparatet mǻ tikoples jordet stikkontakt”
- In Sweden; ”Apparaten skall anslutas till jordat uttag”
Class II apparatus
N/A
- Page 29 of 42 -
Report
No.
123035
IEC 60065
Clause
Requirement – Test
Result - Remark
Verdict
TRF No. IEC60065_I
L
ANNEX L, Additional requirements for electronic flash apparatus for
photographic purposes
photographic purposes
L. 5
Marking and instructions
N/A
L. 5.4
Instructions for battery chargers and Supply
apparatus indicating type or model number of flash
apparatus with which it is to be used ………………:
apparatus indicating type or model number of flash
apparatus with which it is to be used ………………:
No electronic flash apparatus.
N/A
Instructions for flash apparatus indicating type or
model number of battery chargers or Supply
apparatus with which it is to be used ………………:
model number of battery chargers or Supply
apparatus with which it is to be used ………………:
N/A
L. 7
Heating under normal operating conditions
N/A
L7.1.5 &
L11.2.6
Lithium batteries meet permissible temp rise in
Table 3, unless comply with 6.2.2.1.or 6.2.2.2 of
IEC 60086-4 …………………………………………....:
Table 3, unless comply with 6.2.2.1.or 6.2.2.2 of
IEC 60086-4 …………………………………………....:
No lithium batteries
N/A
L. 9
Electric shock hazard under normal operating conditions
N/A
L. 9.1.1
Terminals to connection to synchroniser not
HAZARDOUS LIVE …………………………………:
HAZARDOUS LIVE …………………………………:
Not flash synchroniser.
N/A
L.10 Insulation
requirements
N/A
L. 10.3.2
High frequency pulse ignition………………………..:
N/A
L. 12
Mechanical strength
L. 12.1.3
Windows for flash tubes are excluded from steel ball
impact test ……………………………………………...:
impact test ……………………………………………...:
N/A
L. 14
Components
N/A
L14.6.6
Mains switch characteristics appropriate to its
function under normal conditions …………………….:
function under normal conditions …………………….:
N/A
L. 20
Resistance to fire
N/A
L. 20.1 c)
Trigger coil for discharge purpose is not considered
to be a POTENTIAL IGNITION SOURCE …………..:
to be a POTENTIAL IGNITION SOURCE …………..:
N/A
- Page 30 of 42 -
Report
No.
123035
TRF No. IEC60065_I
7.1
TABLE: temperature rise measurements
P
Power consumption in the OFF/Stand-by position of
the functional switch (W)
the functional switch (W)
Less than 0.85W
—
Operating conditions
Standby mode at 50Hz;
Un (V)
In (A)
Pn (W)
Pout (W)
220 0.004 0.80 —
230 0.004 0.85 —
Standby mode at 60Hz;
Un (V)
In (A)
Pn (W)
Pout (W)
220 0.004 0.66 —
230 0.004 0.70 —
Measured at maximum non-clipped output at 50Hz:
Un (V)
In (A)
Pn (W)
Pout (W)
253
2.42
527
2 x 50.0 W (F)
1 x 47.5 W (C)
2 x 47.0 W (S)
1 x 47.5 W (C)
2 x 47.0 W (S)
Measured at maximum non-clipped output at 60Hz:
Un (V)
In (A)
Pn (W)
Pout (W)
253
2.37
519
2 x 50.0 W (F)
1 x 47.5 W (C)
2 x 47.0 W (S)
1 x 47.5 W (C)
2 x 47.0 W (S)
Tested condition: 1kHz input signal, connected 8 ohm loads for F, C, S channels