- Page 19 of 42 - 
 
 
 
 
 Report 
No. 
123035 
 
IEC 60065 
Clause 
Requirement – Test 
Result - Remark 
Verdict 
 
TRF No. IEC60065_I 
 
 
 
14.6.1 a) 
Separate testing to IEC 61058 including: 
- 10 000 operations 
- Normal pollution suitability 
- Resistance to heat and fire level 3 
- Make and break speed independent of speed of 
  actuation 
V-0 compliance with annex G, G.1.1 ………………...:
Mains switch and relay provided. 
Certified according to  
IEC 61058-1. 
- Mains switch, certified by VDE 
- Mains relay, certified by  
  SEMKO. 
 
See appended table,  
list of critical components. 
14.6.1 b) 
Tested in the apparatus …………….: 
 
N/A 
 
Switch controlling > 0.2A with open contact  voltage 
> 35 V (peak)/24 V dc complying with 14.6.3, 14.6.4 
and V-0 in annex G, G.1.1 ………………….: 
 
N/A 
 
Switch controlling > 0.2A with open contact  voltage 
< 35 V (peak)/24 V dc complying with 14.6.3 and V-0 
in annex G, G.1.1 ……………………………: 
 
N/A 
 
Switch controlling < 0.2A with open contact  voltage 
> 35 V (peak)/24 V dc complying with  14.6.4 and V-
0 in annex G, G.1.1 ……………………………: 
 
N/A 
14.6.2 
Switch tested to 14.6.1 b) constructed to IEC 61058-
1 subclause 13.1 and has making/breaking  action 
independent of speed of actuation ……...: 
Separately approved switch  
and relay. 
N/A 
14.6.3 
Switch tested to 14.6.1 b) compliant with IEC 61058-
1 subclause 16.2.2 d) and  m) not attaining 
excessive temperatures in use ………………: 
Separately approved switch  
and relay. 
N/A 
14.6.4 
Switch tested to 14.6.1 b) has adequate dielectric 
strength ……………………………...….: 
Separately approved switch  
and relay. 
N/A 
14.6.5 
Mains switch controlling mains socket outlets 
additional tests to IEC 60058-1 ………….: 
The apparatus is not provided  
the socket outlet, but measured 
 the apparatus surge through, 
 
- Mains switch: < 1A peak  
- Mains relay: 14 A peak  
 
The measured inrush current  
value is less than rated inrush  
current rating of the mains  
switch and relay. OK. 
 
Socket outlet current marking correct ……………..: 
No mains socket-outlets 
N/A 
14.7 
Safety interlocks  
 
N/A 
 
Safety interlocks to 2.8 of IEC 60950 ……………......:
No safety interlocks 
N/A 
 
 
- Page 20 of 42 - 
 
 
 
 
 Report 
No. 
123035 
 
IEC 60065 
Clause 
Requirement – Test 
Result - Remark 
Verdict 
 
TRF No. IEC60065_I 
 
 
 
14.8 
Voltage setting devices and the like ……………….: 
No voltage setting devices 
N/A 
 
Voltage setting device not likely to be changed 
accidentally ……………………………......: 
 
N/A 
14.9 Motors 
No motors 
N/A 
14.9.1 
Endurance test on motors ………………….: 
 
N/A 
 
Motor start test ……………………………………: 
 
N/A 
 
Dielectric strength test …………………………: 
 
N/A 
14.9.2 
Not adversely affected by oil or grease etc.  …..: 
 
N/A 
14.9.3 
Protection against moving parts …………..: 
 
N/A 
14.9.4 
Motors with phase-shifting capacitors, three-phase 
motors and series motors meet clause. B.8, B.9 and 
B.10 of IEC 60950, Annex B ………………….: 
Not such construction. 
N/A 
14.10 Batteries 
 
N/A 
14.10.1 
Batteries mounted with no risk of accumulation of 
flammable gases …………………………: 
No batteries 
N/A 
14.10.2 
No possibility of recharging non-rechargeable 
batteries …………………………………: 
 
N/A 
14.10.3 
Recharging currents and times within manufacturers 
limits ……………………………………….: 
 
N/A 
 
Lithium batteries discharge and reverse currents 
within the manufacturers limits …………….: 
 
N/A 
14.10.4 
Battery mould stress relief ………………….: 
 
N/A 
14.10.5 
Battery drop test …………………………..: 
 
N/A 
14.11 Optocouplers 
 
 
N/A 
 
Optocouplers comply with Cl. 8 ……………: 
No optocouplers 
N/A 
 
Internal and external dimensions to 13.1. or 
alternatively 13.6 (jointed insulation) ………………: 
 
N/A 
14.12 
Surge suppression varistors  
 
N/A 
 
Comply with IEC 61051-2 …………………..: 
No surge suppression varistors 
N/A 
 
Not connected between mains and accessible parts 
except for earthed parts of permanently connected 
apparatus …………………………….: 
 
N/A 
 
Complies with the current pulse, fire hazard and 
thermal stress requirements of 14.12 …..: 
 
N/A 
 
 
- Page 21 of 42 - 
 
 
 
 
 Report 
No. 
123035 
 
IEC 60065 
Clause 
Requirement – Test 
Result - Remark 
Verdict 
 
TRF No. IEC60065_I 
 
 
 
15 Terminals 
 
15.1.1 
Mains plug, appliance inlet, interconnection couplers 
and mains socket-outlet meet the appropriate 
standard ……………………………………………...: 
Approved mains plug and 
socket-outlet provided,  
See appended table, list of 
critical components. 
 
Overloading of plugs or appliance inlets prevented if 
the apparatus has mains socket outlets …………..: 
No mains socket outlets 
N/A 
 
Overloading of internal wiring prevented if the 
apparatus has mains socket outlets ……………….: 
No mains socket outlets 
N/A 
15.1.2 
Connectors for antenna, earth, audio, video or data: 
 
 
No risk of insertion in mains socket-outlets ……….: 
Only RCA, Antenna, Optical, 
S-video, HDMI terminal used. 
Banana plug type speaker  
terminals also used, but they  
are accepted due to below note
 
Note:  
Banana plug type speaker  
terminals are blocked in their  
axial holes to prevent use of  
plugs that can make  
permanent contact with a  
mains socket outlet. 
 
No risk of insertion into audio or video: outlets 
marked with the symbol of 5.2 ….......................: 
No sockets indicated with the 
symbol 
N/A 
15.1.3 
Output terminals of a.c. adaptors or similar devices 
not compatible with household mains socket-outlets :
Not adaptors used 
N/A 
15.2 
Provision for protective earthing 
 
N/A 
 
Accessible conductive parts of Class I equipment 
reliably connected to earth terminal, within 
equipment  
Class II apparatus 
N/A 
 
Protective earth conductors correctly coloured ……..:
 
N/A 
 
Equipment with non-detachable mains cord provided 
with separate protective earth terminal near mains 
input …...........................................................: 
 
N/A 
 
Protective earth terminal resistant to corrosion ......: 
 
N/A 
 
Earth resistance  test: < 0,1 
Ω at 25 A …………….: 
 
N/A 
15.3 
Terminals for external flexible cords and for 
permanent connection to the mains supply 
 
 
 
- Page 22 of 42 - 
 
 
 
 
 Report 
No. 
123035 
 
IEC 60065 
Clause 
Requirement – Test 
Result - Remark 
Verdict 
 
TRF No. IEC60065_I 
 
 
 
15.3.1 
Adequate terminals for connection of permanent 
wiring …………………………………...….: 
Apparatus is not for permanent 
connection. 
N/A 
15.3.2 
Reliable connection of non-detachable cords …….: 
 
 
Not soldered to conductors of a printed circuit board :
Not soldered 
 
Adequate clearances and creepage distances 
between connections should a wire break away …: 
Wires are clamped two times 
to the contact terminal and 
provided with a two-pole  
connector 
 
Wire secured by additional means to the  
conductor  ……………………………………: 
Adequately anchored. 
Tested with 5 N. 
15.3.3 
Screws and nuts clamping conductors have 
adequate threads: ISO 261, ISO 262 or similar …….:
No screws and nuts clamping 
N/A 
15.3.4 
Soldered conductors wrapped around terminal prior 
to soldering or held in place by additional means …..:
No soldered conductors 
N/A 
 
Clamping of conductor and insulation if not soldered 
or held by screws ………………………………: 
Clamped insulators and 
conductors 
N/A 
15.3.5 
Terminals allow connection of appropriate cross-
sectional area of conductors, for the rated current of 
the equipment ……………………….: 
Terminals have adequate  
connection capacity. 
N/A 
15.3.6 
Terminals to 15.3.3 have sizes required by table 16:
 
N/A 
15.3.7 
Terminals clamp conductors between metal and 
have adequate pressure ………………: 
No clamps. 
N/A 
 
Terminals designed to avoid conductor slipping out 
when tightened or loosened ………………..: 
 
N/A 
 
Terminals adequately fixed to avoid loosening when 
the clamping is tightened or loosened and stress on 
internal wiring is avoided ………………...................: 
 
N/A 
15.3.8 
Terminals carrying a current more than 0,2 A: 
contact pressure not transmitted by insulating 
material except ceramic ……………………….: 
No contact pressure  
transmitted through insulating 
15.3.9 
Termination of non-detachable cords: wires 
terminated near to each other ……………………...: 
The termination of the contacts 
are in adequate proximity to 
each other. 
 
Terminals located and shielded: test with 8 mm 
strand ………………………………: 
Clamped contacts within  
connector 
N/A 
15.4 
Devices forming a part of the mains plug  
 
N/A 